Bruna Ribas Maia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bruna Ribas Maia has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hélinton Goulart Moreira
Universidade Federal de Santa Maria
5 shared publications - Michele Vargas Garcia
Universidade Federal de Santa Maria
5 shared publications - Larissa Coradini
Universidade Federal de Santa Maria
4 shared publications - Christine Grellmann Schumacher
Universidade Federal de Santa Maria, Brasil
3 shared publications - Fabiana Cristina Toillier
Universidade Federal de Santa Maria
3 shared publications - Dayane Domeneghini Didoné
Universidade Federal de Santa Maria, Brasil
2 shared publications
Latest Publications
- Open Access
- 20 February 2026
- Published by Pontifical Catholic University of Sao Paulo (PUC-SP) in Distúrbios da Comunicação
- Vol. 38 (1) , e72973
Teste de função tubária
Introdução: No campo fonoaudiológico, a avaliação da Disfunção de Tuba Auditiva (DTA) utiliza-se de métodos como o Questionário de Autopercepção para Avaliação da Disfunção Obstrutiva da Tuba Auditiva (ETDQ-7) e a pesquisa objetiva com o Teste de Função Tubária (TFT). Ainda não há pesquisas claras que investiguem a eficácia de testes objetivos na mensuração comparada com a autopercepção. Objetivo: Analisar o TFT comparando com o ETDQ-7 e determinar a variação de pressão em daPa apresentada pelos sujeitos saudáveis em cada manobra do teste. Método: Estudo quantitativo, observacional, transversal. Participaram 60 indivíduos, 17 homens e 43 mulheres, com meatoscopia normal, curva timpanométrica A, com ou sem queixas relativas a Tuba Auditiva, distribuídos em dois grupos: G1-indivíduos com autopercepção normal de funcionamento da tuba auditiva(M=28), e G2-com autopercepção de DTA(M=32). Foram realizados os procedimentos: Inspeção Visual do Meato Acústico Externo, Timpanometria, ETDQ-7 e TFT. Resultados: Frente às diferentes condições analisadas, a ordem deglutição(negativar) e após Valsalva(positivar) foi a condição de testagem que apresentou maior porcentagem de especificidade e sensibilidade, sendo respectivamente 46% e 33%. As demais análises demonstraram alta especificidade e baixa sensibilidade. A média de variação de pressão em daPa foi de 36 daPa para Valsalva e sete daPa para deglutição. Conclusão: Ao analisar o TFT, foi observado que realizar o mesmo na condição Deglutição(negativar)+Valsalva(positivar) é o que mais se equivale ao ETDQ-7, realizando a comparação. A variação de pressão em daPa foi estabelecida para ambas as condições, sendo maior na manobra de Valsalva.
- 20 February 2026
- Published by Pontifical Catholic University of Sao Paulo (PUC-SP) in Distúrbios da Comunicação
- Vol. 38 (1) , e72973
Open AccessTeste de função tubária
Introdução: No campo fonoaudiológico, a avaliação da Disfunção de Tuba Auditiva (DTA) utiliza-se de métodos como o Questionário de Autopercepção para Avaliação da Disfunção Obstrutiva da Tuba Auditiva (ETDQ-7) e a pesquisa objetiva com o Teste de Função Tubária (TFT). Ainda não há pesquisas claras que investiguem a eficácia de testes objetivos na mensuração comparada com a autopercepção. Objetivo: Analisar o TFT comparando com o ETDQ-7 e determinar a variação de pressão em daPa apresentada pelos sujeitos saudáveis em cada manobra do teste. Método: Estudo quantitativo, observacional, transversal. Participaram 60 indivíduos, 17 homens e 43 mulheres, com meatoscopia normal, curva timpanométrica A, com ou sem queixas relativas a Tuba Auditiva, distribuídos em dois grupos: G1-indivíduos com autopercepção normal de funcionamento da tuba auditiva(M=28), e G2-com autopercepção de DTA(M=32). Foram realizados os procedimentos: Inspeção Visual do Meato Acústico Externo, Timpanometria, ETDQ-7 e TFT. Resultados: Frente às diferentes condições analisadas, a ordem deglutição(negativar) e após Valsalva(positivar) foi a condição de testagem que apresentou maior porcentagem de especificidade e sensibilidade, sendo respectivamente 46% e 33%. As demais análises demonstraram alta especificidade e baixa sensibilidade. A média de variação de pressão em daPa foi de 36 daPa para Valsalva e sete daPa para deglutição. Conclusão: Ao analisar o TFT, foi observado que realizar o mesmo na condição Deglutição(negativar)+Valsalva(positivar) é o que mais se equivale ao ETDQ-7, realizando a comparação. A variação de pressão em daPa foi estabelecida para ambas as condições, sendo maior na manobra de Valsalva.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 38 (1)
Interpicos dos componentes corticais (P1-N1-P2): um estudo de comparação entre indivíduos típicos e com transtorno do zumbido
RESUMO Objetivo Comparar tempo de resposta neural entre os componentes corticais do Potencial Evocado Auditivo de Longa Latência, medindo a latência e interpicos em indivíduos com e sem zumbido. Método Estudo de caráter analítico, transversal e quantitativo. Participaram do estudo 28 indivíduos, divididos em dois grupos: Grupo Controle, composto por 12 indivíduos sem percepção do zumbido e Grupo Estudo, composto por 16 participantes com transtorno do zumbido. As avaliações foram divididas em dois dias. Inicialmente todos os pacientes foram submetidos a anamnese semi-estruturada, avaliação audiológica básica, testes comportamentais do processamento auditivo central, avaliação neuropsicológica e do zumbido. No segundo dia, foram realizados o PEAC-verbal e o PEATE-neurodiagnóstico. Foram comparadas as respostas da avaliação por meio da latência dos potenciais P1, N1, P2. A análise de comparação entre os grupos foi realizada por meio do teste T para amostras independentes. Resultados Evidenciou-se diferença estatisticamente significante dos valores de interpicos dos potenciais P1-P2 e tendências à significância entre N1-P2 entre os grupos na orelha direita e na comparação de interpicos dos potenciais P1-P2 entre grupos na orelha esquerda. Conclusão Indivíduos com transtorno do zumbido apresentaram interpicos maiores, o que sugere desorganização do funcionamento auditivo central e aumento de resposta entre as interconexões neurais no processamento acústico.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 38 (1)
Open AccessInterpicos dos componentes corticais (P1-N1-P2): um estudo de comparação entre indivíduos típicos e com transtorno do zumbido
RESUMO Objetivo Comparar tempo de resposta neural entre os componentes corticais do Potencial Evocado Auditivo de Longa Latência, medindo a latência e interpicos em indivíduos com e sem zumbido. Método Estudo de caráter analítico, transversal e quantitativo. Participaram do estudo 28 indivíduos, divididos em dois grupos: Grupo Controle, composto por 12 indivíduos sem percepção do zumbido e Grupo Estudo, composto por 16 participantes com transtorno do zumbido. As avaliações foram divididas em dois dias. Inicialmente todos os pacientes foram submetidos a anamnese semi-estruturada, avaliação audiológica básica, testes comportamentais do processamento auditivo central, avaliação neuropsicológica e do zumbido. No segundo dia, foram realizados o PEAC-verbal e o PEATE-neurodiagnóstico. Foram comparadas as respostas da avaliação por meio da latência dos potenciais P1, N1, P2. A análise de comparação entre os grupos foi realizada por meio do teste T para amostras independentes. Resultados Evidenciou-se diferença estatisticamente significante dos valores de interpicos dos potenciais P1-P2 e tendências à significância entre N1-P2 entre os grupos na orelha direita e na comparação de interpicos dos potenciais P1-P2 entre grupos na orelha esquerda. Conclusão Indivíduos com transtorno do zumbido apresentaram interpicos maiores, o que sugere desorganização do funcionamento auditivo central e aumento de resposta entre as interconexões neurais no processamento acústico.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 38 (1)
Interpeak intervals of cortical components (P1-N1-P2): a comparative study between typical individuals and those with tinnitus disorder
Purpose To compare neural response times among cortical components of the Long-Latency Auditory Evoked Potential (LLAEP) by measuring latency and interpeak intervals in individuals with and without tinnitus. Method This was an analytical, cross-sectional, and quantitative study. A total of 28 participants were included, divided into two groups: the Control Group, comprising 12 individuals without tinnitus perception, and the Study Group, comprising 16 individuals diagnosed with tinnitus disorder. Assessments were conducted over two sessions. Initially, all participants underwent a semi-structured anamnesis, basic audiological evaluation, behavioral tests of central auditory processing, as well as neuropsychological and tinnitus assessments. On the second day, verbal LLAEP and neurodiagnostic ABR were performed. The responses were compared by analyzing the latency of P1, N1, and P2 potentials. A between-group comparison was conducted using an independent sample t-test. Results A statistically significant difference was observed in the interpeak intervals of P1-P2 potentials, as well as a trend toward significance in N1-P2 interpeak intervals between groups in the right ear. Additionally, a significant difference was found in P1-P2 interpeak intervals between groups in the left ear. Conclusion Individuals with tinnitus disorder exhibited longer interpeak intervals, suggesting central auditory processing dysfunction and increased neural response within auditory processing pathways.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 38 (1)
Open AccessInterpeak intervals of cortical components (P1-N1-P2): a comparative study between typical individuals and those with tinnitus disorder
Purpose To compare neural response times among cortical components of the Long-Latency Auditory Evoked Potential (LLAEP) by measuring latency and interpeak intervals in individuals with and without tinnitus. Method This was an analytical, cross-sectional, and quantitative study. A total of 28 participants were included, divided into two groups: the Control Group, comprising 12 individuals without tinnitus perception, and the Study Group, comprising 16 individuals diagnosed with tinnitus disorder. Assessments were conducted over two sessions. Initially, all participants underwent a semi-structured anamnesis, basic audiological evaluation, behavioral tests of central auditory processing, as well as neuropsychological and tinnitus assessments. On the second day, verbal LLAEP and neurodiagnostic ABR were performed. The responses were compared by analyzing the latency of P1, N1, and P2 potentials. A between-group comparison was conducted using an independent sample t-test. Results A statistically significant difference was observed in the interpeak intervals of P1-P2 potentials, as well as a trend toward significance in N1-P2 interpeak intervals between groups in the right ear. Additionally, a significant difference was found in P1-P2 interpeak intervals between groups in the left ear. Conclusion Individuals with tinnitus disorder exhibited longer interpeak intervals, suggesting central auditory processing dysfunction and increased neural response within auditory processing pathways.
- Open Access
- 17 March 2025
- Published by Pontifical Catholic University of Sao Paulo (PUC-SP) in Distúrbios da Comunicação
- Vol. 37 (1) , e69005
Componente de interação binaural do potencial evocado auditivo de longa latência com estímulo de fala
Objetivo: Descrever os valores do Componente de Interação Binaural do Potencial Evocado Auditivo de Longa Latência (verbal) em adultos jovens típicos. Método: Trata-se de um estudo observacional descritivo. Dez adultos com limiares auditivos normais, sem queixas auditivas e com processamento auditivo central e cognição normais, foram avaliados. Todos os participantes passaram por uma avaliação audiológica básica, avaliação da autopercepção das habilidades auditivas, avaliação do processamento auditivo central, avaliação neuropsicológica e medição do potencial evocado auditivo de longa latência. Resultados: Foram descritos valores de latência absoluta, amplitude e duração para o componente de interação binaural. Conclusão: O presente estudo forneceu medidas descritivas de latência, amplitude e duração para o componente de interação binaural do potencial evocado auditivo de longa latência.
- 17 March 2025
- Published by Pontifical Catholic University of Sao Paulo (PUC-SP) in Distúrbios da Comunicação
- Vol. 37 (1) , e69005
Open AccessComponente de interação binaural do potencial evocado auditivo de longa latência com estímulo de fala
Objetivo: Descrever os valores do Componente de Interação Binaural do Potencial Evocado Auditivo de Longa Latência (verbal) em adultos jovens típicos. Método: Trata-se de um estudo observacional descritivo. Dez adultos com limiares auditivos normais, sem queixas auditivas e com processamento auditivo central e cognição normais, foram avaliados. Todos os participantes passaram por uma avaliação audiológica básica, avaliação da autopercepção das habilidades auditivas, avaliação do processamento auditivo central, avaliação neuropsicológica e medição do potencial evocado auditivo de longa latência. Resultados: Foram descritos valores de latência absoluta, amplitude e duração para o componente de interação binaural. Conclusão: O presente estudo forneceu medidas descritivas de latência, amplitude e duração para o componente de interação binaural do potencial evocado auditivo de longa latência.
- Open Access
- 14 August 2024
- Published by Pontifical Catholic University of Sao Paulo (PUC-SP) in Distúrbios da Comunicação
- Vol. 36 (2) , e65567
Influência da Prática Musical em Diferentes Habilidades Auditivas
Introdução: A música oferece benefícios psicológicos, cognitivos e sociais, afetando o cérebro de maneiras distintas. O bom funcionamento das habilidades auditivas é fundamental no processo de interpretação de informações sonoras. Objetivo: Comparar o desempenho de adultos em diferentes habilidades auditivas do Processamento Auditivo Central, segundo a variável presença e ausência da prática musical. Método: A amostra foi composta, por conveniência, por 48 adultos com limiares auditivos dentro dos padrões de normalidade, sendo 21 do sexo masculino (43,75%) e 27 do sexo feminino (56,25%), com média de idade de 28,06 anos. Do total, 24 deram origem ao Grupo 1 (G1), isto é, indivíduos com experiência e prática musical e, 24 ao Grupo 2 (G2), grupo sem qualquer prática ou experiência musical. Todos os participantes foram submetidos a uma avaliação audiológica básica e a uma bateria completa de testes comportamentais, a qual foi composta pelo Teste de Identificação de Sentenças Dicóticas(DSI), Masking Level Difference(MLD), Fala Comprimida Adaptado (FCA), Teste de Padrão de Duração e Frequência (TPD e TPF) da Auditec e Random Gap Detection Test (RGDT). Resultados: Houve diferença estatisticamente significativa entre os dois grupos, sendo que o G1 apresentou desempenho superior em todas as habilidades auditivas. Conclusão: Os adultos com experiência e prática musical apresentaram normalidade em todas as habilidades auditivas avaliadas e um desempenho superior estatisticamente significante quando comparado aos seus pares.
- 14 August 2024
- Published by Pontifical Catholic University of Sao Paulo (PUC-SP) in Distúrbios da Comunicação
- Vol. 36 (2) , e65567
Open AccessInfluência da Prática Musical em Diferentes Habilidades Auditivas
Introdução: A música oferece benefícios psicológicos, cognitivos e sociais, afetando o cérebro de maneiras distintas. O bom funcionamento das habilidades auditivas é fundamental no processo de interpretação de informações sonoras. Objetivo: Comparar o desempenho de adultos em diferentes habilidades auditivas do Processamento Auditivo Central, segundo a variável presença e ausência da prática musical. Método: A amostra foi composta, por conveniência, por 48 adultos com limiares auditivos dentro dos padrões de normalidade, sendo 21 do sexo masculino (43,75%) e 27 do sexo feminino (56,25%), com média de idade de 28,06 anos. Do total, 24 deram origem ao Grupo 1 (G1), isto é, indivíduos com experiência e prática musical e, 24 ao Grupo 2 (G2), grupo sem qualquer prática ou experiência musical. Todos os participantes foram submetidos a uma avaliação audiológica básica e a uma bateria completa de testes comportamentais, a qual foi composta pelo Teste de Identificação de Sentenças Dicóticas(DSI), Masking Level Difference(MLD), Fala Comprimida Adaptado (FCA), Teste de Padrão de Duração e Frequência (TPD e TPF) da Auditec e Random Gap Detection Test (RGDT). Resultados: Houve diferença estatisticamente significativa entre os dois grupos, sendo que o G1 apresentou desempenho superior em todas as habilidades auditivas. Conclusão: Os adultos com experiência e prática musical apresentaram normalidade em todas as habilidades auditivas avaliadas e um desempenho superior estatisticamente significante quando comparado aos seus pares.