Alexander N. Harper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexander N. Harper has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Adrian F. Pegoraro
Metrology Research Centre, National Research Council of Canada, Ottawa, Canada
4 shared publications Albert Stolow
University of Ottawa
4 shared publicationsJonathan Boisvert
3 shared publications- Leah Frackleton
Univ. of Ottawa (Canada)
3 shared publications Malcolm Latorre
Univ. of Ottawa (Canada)
3 shared publicationsTassos Grammatikopoulos
3 shared publications
Latest Publications
- 16 July 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 165 (3)
Simple analytical models of spectral focusing stimulated Raman scattering microscopy
Stimulated Raman Scattering (SRS) microscopy is a powerful, rapid label-free, and chemical-specific imaging modality. While the underlying physics is well understood and modeled numerically, we show that, with simple approximations, one can derive equations which enable rapid simulations. Here, we develop an analytical model for spectral focusing SRS microscopy, validate it against numerical simulations, and apply it to the analysis of several experimental implementations. Of use to experimentalists, our model permits rapid simulation of advanced modulation schemes for background (non-Raman) signal removal in SRS microscopy. We compare and discuss their relative advantages and drawbacks.
- 16 July 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 165 (3)
Simple analytical models of spectral focusing stimulated Raman scattering microscopy
Stimulated Raman Scattering (SRS) microscopy is a powerful, rapid label-free, and chemical-specific imaging modality. While the underlying physics is well understood and modeled numerically, we show that, with simple approximations, one can derive equations which enable rapid simulations. Here, we develop an analytical model for spectral focusing SRS microscopy, validate it against numerical simulations, and apply it to the analysis of several experimental implementations. Of use to experimentalists, our model permits rapid simulation of advanced modulation schemes for background (non-Raman) signal removal in SRS microscopy. We compare and discuss their relative advantages and drawbacks.
- Open Access
- 14 May 2026
- Published by Elsevier in Minerals Engineering
- Vol. 245
Applications of stimulated Raman scattering microscopy to mineralogy: Real-time quantification of spodumene in lithium-bearing ores
- 14 May 2026
- Published by Elsevier in Minerals Engineering
- Vol. 245
Open AccessApplications of stimulated Raman scattering microscopy to mineralogy: Real-time quantification of spodumene in lithium-bearing ores
- 9 September 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (19) , 39406-39425
Lock-in amplitude-phase correlations for enhanced imaging and segmentation in stimulated Raman scattering microscopy
Modulation transfer-based signal recovery methods, such as stimulated Raman scattering (SRS) microscopy, commonly use lock-in amplifier amplitude and phase outputs, with each providing readily accessible yet complementary information. Here we show that 2D amplitude-phase correlations enhance both imaging and segmentation (chemical specificity) in spectral focusing SRS microscopy, exemplified here by the characterization of an economic lithium ore sample. We additionally demonstrate that bilateral filtering applied to 2D amplitude-phase correlations leads to improved edge-preserving imaging.
- 9 September 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (19) , 39406-39425
Lock-in amplitude-phase correlations for enhanced imaging and segmentation in stimulated Raman scattering microscopy
Modulation transfer-based signal recovery methods, such as stimulated Raman scattering (SRS) microscopy, commonly use lock-in amplifier amplitude and phase outputs, with each providing readily accessible yet complementary information. Here we show that 2D amplitude-phase correlations enhance both imaging and segmentation (chemical specificity) in spectral focusing SRS microscopy, exemplified here by the characterization of an economic lithium ore sample. We additionally demonstrate that bilateral filtering applied to 2D amplitude-phase correlations leads to improved edge-preserving imaging.
- 19 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13325, 9-15
Lock-in amplitude-phase correlations in coherent Raman microscopy: application to lithium ores
In Stimulated Raman Scattering (SRS) Microscopy, which is typically based on modulation transfer techniques, the Lock-In amplitude and phase provide easily measured, complementary information. This information characterizes both the strength of a signal and the lifetime of the underlying process on a per-pixel basis. Despite these advantages, interpreting the phase information becomes challenging when several nonlinear optical processes occur simultaneously, as is particularly noticeable when pump-probe type signals are present. Here, we use spectral focusing SRS Microscopy to characterize a lithium ore sample. Spectral focusing SRS microscopy is based on linearly chirping the input pulses so as to achieve high Raman spectral resolution through the narrowed instantaneous bandwidth. By scanning the inter-pulse time delay, the instantaneous difference frequency and consequently, the Raman shift probed is tuned. Unfortunately, this also makes the process sensitive to delayed pump-probe signals, as shown here for lithium ore samples. We show that by using both phase and amplitude lock-in amplifier information, we can fully characterize the competing nonlinear processes which contribute during a pump-probe time-delay scan.
- 19 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13325, 9-15
Lock-in amplitude-phase correlations in coherent Raman microscopy: application to lithium ores
In Stimulated Raman Scattering (SRS) Microscopy, which is typically based on modulation transfer techniques, the Lock-In amplitude and phase provide easily measured, complementary information. This information characterizes both the strength of a signal and the lifetime of the underlying process on a per-pixel basis. Despite these advantages, interpreting the phase information becomes challenging when several nonlinear optical processes occur simultaneously, as is particularly noticeable when pump-probe type signals are present. Here, we use spectral focusing SRS Microscopy to characterize a lithium ore sample. Spectral focusing SRS microscopy is based on linearly chirping the input pulses so as to achieve high Raman spectral resolution through the narrowed instantaneous bandwidth. By scanning the inter-pulse time delay, the instantaneous difference frequency and consequently, the Raman shift probed is tuned. Unfortunately, this also makes the process sensitive to delayed pump-probe signals, as shown here for lithium ore samples. We show that by using both phase and amplitude lock-in amplifier information, we can fully characterize the competing nonlinear processes which contribute during a pump-probe time-delay scan.
- 19 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13353, 23-31
Fringe-averaged collinear frequency-resolved optical gating: in situ characterization of ultrashort pulses in nonlinear microscopy
The full characterization of the electric field of ultrashort laser pulses is important in multiphoton microscopy. This must be achieved at the focal plane of the microscope objective (in situ), requiring a collinear geometry. A well-known option for collinear pulse characterization is the second-harmonic generation collinear Frequency Resolved Optical Gating (SHG-cFROG) technique. Previous implementations of SHG-cFROG have involved Type I/Type II phase matching with Fourier filtering to remove fringes, novel algorithms for cFROG interferograms, and pulse shaper generation of collinear phase locked pairs. However, these approaches are potentially challenged by aspects of: 1) interferometric drift, of particular concern for longer pulses; 2) technical and/or algorithmic complexity; and 3) long acquisition times (high density sampling). To address these issues, we introduce a variation of SHG-cFROG named Fringe-averaged collinear FROG (FRACOL-FROG), which relies on using a kHz piezo-driven retroreflector to dither the path length of one arm of the collinear FROG interferometer. By averaging over interference fringes during the integration time of the spectrometer, we demonstrate: 1) robustness with respect to interferometric drift; 2) the ability to use standard FROG retrieval algorithms; 3) dramatic reduction in the density of sampling points without loss of resolution (⪆200-fold speedup); and 4) quantitative tabletop and in situ characterization of highly chirped pulses (~100 fs-3 ps). FRACOL-FROG is a rapid and robust method well suited to the complete in situ characterization of shaped ultrashort pulses in multiphoton microscopy.
- 19 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13353, 23-31
Fringe-averaged collinear frequency-resolved optical gating: in situ characterization of ultrashort pulses in nonlinear microscopy
The full characterization of the electric field of ultrashort laser pulses is important in multiphoton microscopy. This must be achieved at the focal plane of the microscope objective (in situ), requiring a collinear geometry. A well-known option for collinear pulse characterization is the second-harmonic generation collinear Frequency Resolved Optical Gating (SHG-cFROG) technique. Previous implementations of SHG-cFROG have involved Type I/Type II phase matching with Fourier filtering to remove fringes, novel algorithms for cFROG interferograms, and pulse shaper generation of collinear phase locked pairs. However, these approaches are potentially challenged by aspects of: 1) interferometric drift, of particular concern for longer pulses; 2) technical and/or algorithmic complexity; and 3) long acquisition times (high density sampling). To address these issues, we introduce a variation of SHG-cFROG named Fringe-averaged collinear FROG (FRACOL-FROG), which relies on using a kHz piezo-driven retroreflector to dither the path length of one arm of the collinear FROG interferometer. By averaging over interference fringes during the integration time of the spectrometer, we demonstrate: 1) robustness with respect to interferometric drift; 2) the ability to use standard FROG retrieval algorithms; 3) dramatic reduction in the density of sampling points without loss of resolution (⪆200-fold speedup); and 4) quantitative tabletop and in situ characterization of highly chirped pulses (~100 fs-3 ps). FRACOL-FROG is a rapid and robust method well suited to the complete in situ characterization of shaped ultrashort pulses in multiphoton microscopy.
- 29 August 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (19) , 33090-33103
Fringe-averaged collinear frequency-resolved optical gating: in situ characterization of ultrashort pulses in nonlinear microscopy
In situ characterization of the electric field of ultrafast pulses is critical in multiphoton microscopy. Although second harmonic generation-based collinear Frequency-Resolved Optical Gating (FROG) addresses this need, the interferometric measurement is challenged by interferometric drift instability, the required high sampling density of the acquired data, and the inability to directly use the interferometric data with conventional FROG retrieval algorithms. We address these issues by combining low-pass Fourier filtering with active kHz dithering of the interferometric path length difference using a piezo-driven retroreflector. We demonstrate successful electric field retrieval for pulses of variable duration (∼100 fs-3 ps), in situ characterization of a chirped pulse in a nonlinear microscope, and a significant reduction in acquisition time, without loss of resolution, by undersampling.
- 29 August 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (19) , 33090-33103
Fringe-averaged collinear frequency-resolved optical gating: in situ characterization of ultrashort pulses in nonlinear microscopy
In situ characterization of the electric field of ultrafast pulses is critical in multiphoton microscopy. Although second harmonic generation-based collinear Frequency-Resolved Optical Gating (FROG) addresses this need, the interferometric measurement is challenged by interferometric drift instability, the required high sampling density of the acquired data, and the inability to directly use the interferometric data with conventional FROG retrieval algorithms. We address these issues by combining low-pass Fourier filtering with active kHz dithering of the interferometric path length difference using a piezo-driven retroreflector. We demonstrate successful electric field retrieval for pulses of variable duration (∼100 fs-3 ps), in situ characterization of a chirped pulse in a nonlinear microscope, and a significant reduction in acquisition time, without loss of resolution, by undersampling.