Claudia Alessandra Manetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Claudia Alessandra Manetti has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Joost Lumens
Department of Biomedical Engineering, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University , Maastricht
4 shared publications - Ahmed S. Beela
Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University Medical Center , Universiteitssingel 40, 6229 ERMaastricht
3 shared publications - Tammo Delhaas
Department of Biomedical Engineering, Cardiovascular Research Institute Maastricht (CARIM) and Heart & Vessel Center Maastricht University Medical Center Maastricht the Netherlands
3 shared publications - Lieven Herbots
Jessa Hospital
2 shared publications - Nick van Osta
Maastricht University
2 shared publications Frits W Prinzen
Department of Physiology, Maastricht University , 6200 MD Maastricht
1 shared publication
Latest Publications
- Open Access
- 28 March 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (4)
Impact of myocardial phenotype on optimal atrioventricular delay settings during biventricular and left bundle branch pacing at rest and during exercise: insights from a virtual patient study
Aims: Previous studies have not examined the role of non-electrical myocardial disease substrates in determining the optimal atrio-ventricular delay (AVD) settings. We conducted virtual patient simulations to evaluate whether myocardial disease substrates influence the acute response to AVD optimization at rest and during exercise. Methods and results: The CircAdapt cardiovascular model was used to simulate various left ventricular (LV) remodelling found in cardiac resynchronization therapy candidates. We simulated electrical dyssynchrony, LV dilatation with preserved and reduced contractility, and increased LV passive stiffness. We simulated cardiac resynchronization following biventricular (BiVP) and non-selective LBB pacing (nsLBBP). The paced-AVD ranged from 220 to 40 ms. Cardiac output and heart rate were increased to simulate different levels of exercise. The optimal AVD was the one leading to the highest stroke volume (SV) and the lowest mean left atrial pressure (mLAP). At rest, in simulations with healthy myocardium the gain in SV by AVD optimization was larger compared to those with reduced contractility and stiff myocardium. However, mLAP was comparably decreased by AVD optimization in both healthy and diseased myocardium. During exercise, the optimal AVD shifted to shorter values, and mLAP was more sensitive to AVD, particularly in the presence of hypo-contractile and stiff myocardium. Conclusion: Simulations show that hypocontractility and stiffness reduce the effect of AVD optimization on SV but enhance its benefit in lowering mLAP. Notably, virtual patients with stiff ventricles experience greater benefits from AVD optimization during exercise compared to resting conditions. Furthermore, nsLBBP provides more favourable improvements in mLAP than BiVP.
- 28 March 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (4)
Open AccessImpact of myocardial phenotype on optimal atrioventricular delay settings during biventricular and left bundle branch pacing at rest and during exercise: insights from a virtual patient study
Aims: Previous studies have not examined the role of non-electrical myocardial disease substrates in determining the optimal atrio-ventricular delay (AVD) settings. We conducted virtual patient simulations to evaluate whether myocardial disease substrates influence the acute response to AVD optimization at rest and during exercise. Methods and results: The CircAdapt cardiovascular model was used to simulate various left ventricular (LV) remodelling found in cardiac resynchronization therapy candidates. We simulated electrical dyssynchrony, LV dilatation with preserved and reduced contractility, and increased LV passive stiffness. We simulated cardiac resynchronization following biventricular (BiVP) and non-selective LBB pacing (nsLBBP). The paced-AVD ranged from 220 to 40 ms. Cardiac output and heart rate were increased to simulate different levels of exercise. The optimal AVD was the one leading to the highest stroke volume (SV) and the lowest mean left atrial pressure (mLAP). At rest, in simulations with healthy myocardium the gain in SV by AVD optimization was larger compared to those with reduced contractility and stiff myocardium. However, mLAP was comparably decreased by AVD optimization in both healthy and diseased myocardium. During exercise, the optimal AVD shifted to shorter values, and mLAP was more sensitive to AVD, particularly in the presence of hypo-contractile and stiff myocardium. Conclusion: Simulations show that hypocontractility and stiffness reduce the effect of AVD optimization on SV but enhance its benefit in lowering mLAP. Notably, virtual patients with stiff ventricles experience greater benefits from AVD optimization during exercise compared to resting conditions. Furthermore, nsLBBP provides more favourable improvements in mLAP than BiVP.
- Open Access
- 8 November 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 26 (3) , 424-434
The mechanistic interaction between mechanical dyssynchrony and filling pressure in cardiac resynchronisation therapy candidates
Aims: Both left ventricular (LV) mechanical dyssynchrony and filling pressure have been shown to be associated with outcome in heart failure patient treated with cardiac resynchronisation therapy (CRT). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure and to assess their combined prognostic value in CRT candidates. Methods and results: Left atrial pressure (LAP) estimation and quantification of mechanical dyssynchrony were retrospectively performed in 219 CRT patients using echocardiography. LAP was elevated (eLAP) in 49% of the population, normal (nLAP) in 40%, and indeterminate in 11%. CRT response was defined as per cent-decrease in LV end-systolic volume after 12 ± 6 months CRT. Clinical endpoint was all-cause mortality during 4.8 years (interquartile range: 2.7–6.0 years). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure, the CircAdapt computer model was used to simulate cardiac mechanics and haemodynamics in virtual hearts with left bundle branch block (LBBB) and various causes of increased filling pressure. Patients with nLAP had more significant mechanical dyssynchrony than those with eLAP. The combined assessment of both parameters before CRT was significantly associated with reverse LV remodelling and post-CRT survival. Simulations revealed that mechanical dyssynchrony is attenuated by increased LV operational chamber stiffness, regardless of whether it is caused by passive or active factors, explaining the link between mechanical dyssynchrony and filling pressure. Conclusion: Our combined clinical-computational data demonstrate that in patients with LBBB, the presence of mechanical dyssynchrony indicates relatively normal LV compliance and low filling pressure, which may explain their strong association with positive outcomes after CRT.
- 8 November 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 26 (3) , 424-434
Open AccessThe mechanistic interaction between mechanical dyssynchrony and filling pressure in cardiac resynchronisation therapy candidates
Aims: Both left ventricular (LV) mechanical dyssynchrony and filling pressure have been shown to be associated with outcome in heart failure patient treated with cardiac resynchronisation therapy (CRT). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure and to assess their combined prognostic value in CRT candidates. Methods and results: Left atrial pressure (LAP) estimation and quantification of mechanical dyssynchrony were retrospectively performed in 219 CRT patients using echocardiography. LAP was elevated (eLAP) in 49% of the population, normal (nLAP) in 40%, and indeterminate in 11%. CRT response was defined as per cent-decrease in LV end-systolic volume after 12 ± 6 months CRT. Clinical endpoint was all-cause mortality during 4.8 years (interquartile range: 2.7–6.0 years). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure, the CircAdapt computer model was used to simulate cardiac mechanics and haemodynamics in virtual hearts with left bundle branch block (LBBB) and various causes of increased filling pressure. Patients with nLAP had more significant mechanical dyssynchrony than those with eLAP. The combined assessment of both parameters before CRT was significantly associated with reverse LV remodelling and post-CRT survival. Simulations revealed that mechanical dyssynchrony is attenuated by increased LV operational chamber stiffness, regardless of whether it is caused by passive or active factors, explaining the link between mechanical dyssynchrony and filling pressure. Conclusion: Our combined clinical-computational data demonstrate that in patients with LBBB, the presence of mechanical dyssynchrony indicates relatively normal LV compliance and low filling pressure, which may explain their strong association with positive outcomes after CRT.
- Open Access
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 117040-117055
Large-Scale Simulation of Realistic Cardiac Ultrasound Data With Clinical Appearance: Methodology and Open-Access Database
Cardiac ultrasound imaging is widely used in the clinical setting. Deep learning algorithms have shown increased potential in automating routine clinical tasks for improved diagnosis and prognosis. However, the lack of large and diverse training databases hinders their employment on a full scale in clinics. Difficulties associated with creating large training databases include scarcity of clinical data, privacy related data access concerns and labor-intensive ground-truth annotations. To overcome these issues, realistic cardiac ultrasound simulation is considered advantageous. Nevertheless, our state-of-the-art cardiac ultrasound simulation pipeline is limited to small-scale databases particularly because of the underlying computationally complex finite-element heart model. In this paper, we developed a realistic simulation pipeline to facilitate large-scale synthetic cardiac ultrasound datasets. This pipeline utilizes a well-validated and computationally efficient lump-parameter heart model for generating cardiovascular mechanics, and the convolution based ultrasound simulator COLE for short simulation times. We implemented the proposed pipeline to create a large open-access database of 2-D realistic cardiac ultrasound recordings with diversity in the geometries, ultrasound speckle texture and motions of the left ventricle. Quantitative assessment of the simulated data demonstrated that the synthetic cardiac ultrasound frames contained realistic speckle patterns. Moreover, the left ventricular motion in the simulated frames was tracked using the medical imaging tracking toolbox and was shown to closely match the kinematically imposed ground-truth left ventricular motion. The presented pipeline is valuable for creating large and diverse ground-truth training databases. The resulting database is a potential augmentation tool for machine learning-based ultrasound data processing algorithms and made publicly available.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 117040-117055
Open AccessLarge-Scale Simulation of Realistic Cardiac Ultrasound Data With Clinical Appearance: Methodology and Open-Access Database
Cardiac ultrasound imaging is widely used in the clinical setting. Deep learning algorithms have shown increased potential in automating routine clinical tasks for improved diagnosis and prognosis. However, the lack of large and diverse training databases hinders their employment on a full scale in clinics. Difficulties associated with creating large training databases include scarcity of clinical data, privacy related data access concerns and labor-intensive ground-truth annotations. To overcome these issues, realistic cardiac ultrasound simulation is considered advantageous. Nevertheless, our state-of-the-art cardiac ultrasound simulation pipeline is limited to small-scale databases particularly because of the underlying computationally complex finite-element heart model. In this paper, we developed a realistic simulation pipeline to facilitate large-scale synthetic cardiac ultrasound datasets. This pipeline utilizes a well-validated and computationally efficient lump-parameter heart model for generating cardiovascular mechanics, and the convolution based ultrasound simulator COLE for short simulation times. We implemented the proposed pipeline to create a large open-access database of 2-D realistic cardiac ultrasound recordings with diversity in the geometries, ultrasound speckle texture and motions of the left ventricle. Quantitative assessment of the simulated data demonstrated that the synthetic cardiac ultrasound frames contained realistic speckle patterns. Moreover, the left ventricular motion in the simulated frames was tracked using the medical imaging tracking toolbox and was shown to closely match the kinematically imposed ground-truth left ventricular motion. The presented pipeline is valuable for creating large and diverse ground-truth training databases. The resulting database is a potential augmentation tool for machine learning-based ultrasound data processing algorithms and made publicly available.