Geethanjali Kher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Geethanjali Kher has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Rajni Bala
2 shared publications- Rajni Bala
University of Delhi
2 shared publications Ram Pal Singh
2 shared publications- Ram Pal Singh
University of Delhi, Delhi
2 shared publications Vanshika Singh
Indira Gandhi Delhi Technical University For Women, Delhi
2 shared publications- Vikash Chaudhary
University of Delhi
2 shared publications
Latest Publications
- Open Access
- 20 July 2026
- Published by The ScienceIn Publishing in Journal of Integrated Science and Technology
- Vol. 14 (9) , 1635
LX-OcuWav: Lightweight and explainable diagnostics for Ocular diseases using spatial and wavelet features
Healthy vision is essential to maintain independence, confidence, and an active lifestyle. Early detection of ocular diseases can help preserve vision. However, limited access to ophthalmologists remains a major challenge, particularly in developing regions. This study aims to develop a lightweight, explainable and efficient decision support framework for the automated classification of ocular diseases. This can help ophthalmologists handle patients who need immediate attention. The proposed model combines wavelet-derived features with RGB fundus image representations, adapting the pretrained model’s weights to create a compact and domain-efficient architecture. The wavelet transform enables multi-resolution analysis, allowing the network to capture both coarse and fine image structures, such as edges and textures, thereby improving feature discrimination. Furthermore, the model incorporates explainability via GradCAM to provide visual insight into its predictions. The framework achieves a top-1 diagnostic accuracy of 97.14% and a top-2 accuracy of 99.74%, outperforming comparable deep learning models in the classification of multiclass retinal diseases. This study demonstrates that integrating wavelet-based features with deep learning architectures improves both interpretability and performance. The lightweight and interpretable nature of the model makes it suitable for real-world deployment in resource limited healthcare settings. This contributes to an early and accessible diagnosis of ocular diseases.
- 20 July 2026
- Published by The ScienceIn Publishing in Journal of Integrated Science and Technology
- Vol. 14 (9) , 1635
Open AccessLX-OcuWav: Lightweight and explainable diagnostics for Ocular diseases using spatial and wavelet features
Healthy vision is essential to maintain independence, confidence, and an active lifestyle. Early detection of ocular diseases can help preserve vision. However, limited access to ophthalmologists remains a major challenge, particularly in developing regions. This study aims to develop a lightweight, explainable and efficient decision support framework for the automated classification of ocular diseases. This can help ophthalmologists handle patients who need immediate attention. The proposed model combines wavelet-derived features with RGB fundus image representations, adapting the pretrained model’s weights to create a compact and domain-efficient architecture. The wavelet transform enables multi-resolution analysis, allowing the network to capture both coarse and fine image structures, such as edges and textures, thereby improving feature discrimination. Furthermore, the model incorporates explainability via GradCAM to provide visual insight into its predictions. The framework achieves a top-1 diagnostic accuracy of 97.14% and a top-2 accuracy of 99.74%, outperforming comparable deep learning models in the classification of multiclass retinal diseases. This study demonstrates that integrating wavelet-based features with deep learning architectures improves both interpretability and performance. The lightweight and interpretable nature of the model makes it suitable for real-world deployment in resource limited healthcare settings. This contributes to an early and accessible diagnosis of ocular diseases.
- Open Access
- 2 February 2026
- Published by The ScienceIn Publishing in Journal of Integrated Science and Technology
- Vol. 14 (3) , 1541
Finite Newton-Armijo iterative method for extreme learning machine-based digital watermarking of color images
In this paper, we propose the implementation of optimization based Extreme Learning Machine using the Finite Newton-Armijo method (FNELM) for digital watermarking of color images. The Finite Newton-Armijo method for ELM convergence is established and mathematically justified. The ELM is a regularized algorithm based on generalized single-hidden-layer feedforward neural networks (SLFNs). However, a hidden layer in the context of ELM, this is commonly referred to as "feature mapping," so you do not have to tune it again and again. This paper includes the embedding and extraction processes of a watermark, a logo, or a sequence of numbers in a color image with the help of the said machine. As a result, the ELM provides better generalization performance, the approach tends to deliver superior performance by simultaneously reaching the lowest training error and the smallest norm of the output weights. The efficacy of the FNELM algorithm is measured using the Peak Signal-to-Noise Ratio (PSNR), Bit Error Rate (BER), and other qualitative parameters. Retrieval rate R and normalized correlation coefficient (NC) on signed images and, further, on attacked images created by applying malicious attacks over them. The results obtained are compared with some existing methods, and the proposed method outperformed them in comparison.
- 2 February 2026
- Published by The ScienceIn Publishing in Journal of Integrated Science and Technology
- Vol. 14 (3) , 1541
Open AccessFinite Newton-Armijo iterative method for extreme learning machine-based digital watermarking of color images
In this paper, we propose the implementation of optimization based Extreme Learning Machine using the Finite Newton-Armijo method (FNELM) for digital watermarking of color images. The Finite Newton-Armijo method for ELM convergence is established and mathematically justified. The ELM is a regularized algorithm based on generalized single-hidden-layer feedforward neural networks (SLFNs). However, a hidden layer in the context of ELM, this is commonly referred to as "feature mapping," so you do not have to tune it again and again. This paper includes the embedding and extraction processes of a watermark, a logo, or a sequence of numbers in a color image with the help of the said machine. As a result, the ELM provides better generalization performance, the approach tends to deliver superior performance by simultaneously reaching the lowest training error and the smallest norm of the output weights. The efficacy of the FNELM algorithm is measured using the Peak Signal-to-Noise Ratio (PSNR), Bit Error Rate (BER), and other qualitative parameters. Retrieval rate R and normalized correlation coefficient (NC) on signed images and, further, on attacked images created by applying malicious attacks over them. The results obtained are compared with some existing methods, and the proposed method outperformed them in comparison.
- Open Access
- 12 March 2025
- Published by Elsevier in Informatics in Medicine Unlocked
- Vol. 54
DeB5-XNet: An explainable ensemble model for ocular disease classification using feature extraction and Grad-CAM
- 12 March 2025
- Published by Elsevier in Informatics in Medicine Unlocked
- Vol. 54
Open AccessDeB5-XNet: An explainable ensemble model for ocular disease classification using feature extraction and Grad-CAM
- Open Access
- 26 August 2024
- Published by Wiley
DeB5-XNet: An Explainable Ensemble Model for Ocular Disease Classification using Transfer Learning and Grad-CAM
Vision is ones’ window to the world, enabling individuals to fully engage in and enjoy various aspects of daily life. Diseases can result in loss of vision. Developing an automated diagnostic system is crucial to support the limited number of ophthalmologists in managing the growing number of patients with severe ocular diseases. This research proposes a multiclass diagnostic system for identifying three ocular diseases: Diabetic Retinopathy (DR), Glaucoma (G), and Cataract (C). The study begins by identifying Contrast-Limited Adaptive Histogram Equalization (CLAHE) in LAB color space as an effective image enhancement technique for fundus photographs (FP). By leveraging the unique architectures of various pre-trained models, different features of an image are identified. We evaluate combinations of seven pre-trained models and find that the combination of DenseNet121 and EfficientNetB5 (DeB5-XNet) achieves the highest test accuracy of 95%, with a significant reduction in false negatives compared to individual models. Grad-CAM is then employed to provide a visual explanation of our ensemble model’s predictions, demonstrating that the features captured by the model are aligned closely with those utilized by ophthalmologists for diagnosis.
- 26 August 2024
- Published by Wiley
Open AccessDeB5-XNet: An Explainable Ensemble Model for Ocular Disease Classification using Transfer Learning and Grad-CAM
Vision is ones’ window to the world, enabling individuals to fully engage in and enjoy various aspects of daily life. Diseases can result in loss of vision. Developing an automated diagnostic system is crucial to support the limited number of ophthalmologists in managing the growing number of patients with severe ocular diseases. This research proposes a multiclass diagnostic system for identifying three ocular diseases: Diabetic Retinopathy (DR), Glaucoma (G), and Cataract (C). The study begins by identifying Contrast-Limited Adaptive Histogram Equalization (CLAHE) in LAB color space as an effective image enhancement technique for fundus photographs (FP). By leveraging the unique architectures of various pre-trained models, different features of an image are identified. We evaluate combinations of seven pre-trained models and find that the combination of DenseNet121 and EfficientNetB5 (DeB5-XNet) achieves the highest test accuracy of 95%, with a significant reduction in false negatives compared to individual models. Grad-CAM is then employed to provide a visual explanation of our ensemble model’s predictions, demonstrating that the features captured by the model are aligned closely with those utilized by ophthalmologists for diagnosis.