Daniela Zemkova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniela Zemkova has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ivo Marik
Centre for Defects of Locomotor Apparatus l.l.c., Prague, Czech Republic
2 shared publications - Krawczyk Petr
Department of Orthopedics and Prosthetics, PROTEOR CZ l.l.c., Ostrava, Czech Republic
2 shared publications Ales Sykora
PROTEOR CZ LLC, Ostrava, Czech Republic
1 shared publication- Aneta Kodytková
Department of Pediatrics, 2nd Faculty of Medicine, Charles University and Motol University Hospital, Czechia
1 shared publication - Barbora Obermannova
Department of Paediatrics, 2nd Faculty of Medicine, Charles University, Prague, Czechia
1 shared publication - Božena Kalvachová
Institute of Endocrinology , Prague , Czech Republic
1 shared publication
Latest Publications
- 14 March 2025
- Published by Walter de Gruyter GmbH in Journal of Pediatric Endocrinology and Metabolism
- Vol. 38 (5) , 525-532
Early-onset growth hormone treatment in Prader–Willi syndrome attenuates transition to severe obesity
Objectives: Subsequent to early life feeding issues, children with Prader–Willi syndrome (PWS) develop hyperphagia and severe obesity. Growth hormone (GH) therapy has been approved in PWS to improve growth, body composition, and BMI. We aimed to clarify the role of age at GH therapy onset on growth and BMI trajectories in children with PWS. Methods: We analyzed height and BMI in 114 patients (58 boys) from REPAR – Czech national GH registry. From them, 69 started GH therapy prior to 2 y/o (age 0.8 ± 0.4 years; mean ± SD; early-onset group [EO]), and 45 later (age 7.1 ± 4.1 years; late-onset group [LO]). Results: Height-SDS before therapy was similar in all (EO: −1.9 ± 1.2 [mean ± SD]; LO: −1.7 ± 1.1). After the first year of GH therapy, height-SDS in the EO group increased to −1.0 ± 1.2, in the LO group to −0.9 ± 1.1. After 5 years, height fully normalized in all (−0.1 ± 1.1 SDS). The LO children were already obese at treatment initiation (BMI-SDS: 2.9 ± 2.2), and their BMI-SDS decreased after 1 year of GH therapy by 0.9 (p=0.003). The weight in EO children was below average before GH treatment (BMI-SDS: −0.9 ± 1.2) and their BMI-SDS increased to the overweight range of 1.3 ± 2.2 (p<0.001) within the oncoming 3 years. Albeit BMI-SDS was around the obesity limit in most children after 5 years on GH therapy, the highest lifetime BMI-SDS was lower in EO (2.2 ± 2.6) than in LO (3.7 ± 2.2; p<0.001). Conclusions: GH treatment in PWS normalizes body height. After 5 years of GH therapy, BMI-SDS in EO and LO groups are similar; however, the EO group is exposed to lower maximal BMI-SDS values.
- 14 March 2025
- Published by Walter de Gruyter GmbH in Journal of Pediatric Endocrinology and Metabolism
- Vol. 38 (5) , 525-532
Early-onset growth hormone treatment in Prader–Willi syndrome attenuates transition to severe obesity
Objectives: Subsequent to early life feeding issues, children with Prader–Willi syndrome (PWS) develop hyperphagia and severe obesity. Growth hormone (GH) therapy has been approved in PWS to improve growth, body composition, and BMI. We aimed to clarify the role of age at GH therapy onset on growth and BMI trajectories in children with PWS. Methods: We analyzed height and BMI in 114 patients (58 boys) from REPAR – Czech national GH registry. From them, 69 started GH therapy prior to 2 y/o (age 0.8 ± 0.4 years; mean ± SD; early-onset group [EO]), and 45 later (age 7.1 ± 4.1 years; late-onset group [LO]). Results: Height-SDS before therapy was similar in all (EO: −1.9 ± 1.2 [mean ± SD]; LO: −1.7 ± 1.1). After the first year of GH therapy, height-SDS in the EO group increased to −1.0 ± 1.2, in the LO group to −0.9 ± 1.1. After 5 years, height fully normalized in all (−0.1 ± 1.1 SDS). The LO children were already obese at treatment initiation (BMI-SDS: 2.9 ± 2.2), and their BMI-SDS decreased after 1 year of GH therapy by 0.9 (p=0.003). The weight in EO children was below average before GH treatment (BMI-SDS: −0.9 ± 1.2) and their BMI-SDS increased to the overweight range of 1.3 ± 2.2 (p<0.001) within the oncoming 3 years. Albeit BMI-SDS was around the obesity limit in most children after 5 years on GH therapy, the highest lifetime BMI-SDS was lower in EO (2.2 ± 2.6) than in LO (3.7 ± 2.2; p<0.001). Conclusions: GH treatment in PWS normalizes body height. After 5 years of GH therapy, BMI-SDS in EO and LO groups are similar; however, the EO group is exposed to lower maximal BMI-SDS values.
- Open Access
- 3 January 2024
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 58 (3) , 155-160
Lower extremity length discrepancy solution by modified drilling epiphysiodesis and anthropological prediction methods: long-term results
Objective: This study aimed to summarize our experience with modified drilling epiphysiodesis and prediction methods for accurate timing of surgery and to compare the results with those of recent work by other authors. Methods: The Macnicol and Gupta modified drilling technique was used. Distal femoral and/or proximal tibial permanent epiphysiodesis was performed in 42 children (21 boys, 21 girls; median age at surgery=12.6 years, age range=9.4-15.4 years) between 2004 and 2016. Based on the groundwork of previous studies, we developed an auxological prediction method. The limb length discrepancy (LLD) was assessed by clinical examination and verified by an x-ray of the hips when standing with blocks under the shorter leg. Results: The predicted shortening was 2.7 cm ± 1.1 cm. The final discrepancy after finishing skeletal growth was 0.5 ± 0.5 cm. In 26 patients (61.9%), equalization of both legs was achieved (0-0.5 cm). In 4 patients (9.5%), the remaining shortening was more than 1.0 cm. Shortening of an initially longer leg occurred in two patients (0.5 cm and 0.6 cm). Failure of growth plate arrest was observed in 1 patient. In another 3 patients, the efficacy of tibial epiphysiodesis was unsatisfactory. Minor complications occurred in 5 cases, but there was no evidence of angular deformity in the frontal and sagittal planes or proximal fibula overgrowth. Three patients (7.1%) returned to the operating room. Compared to published data, more patients achieved complete equalization of leg length. Conclusion: The results of this study verified the accuracy of the auxological prediction algorithm of LLD based on Shapiro’s findings. The surgical outcome is comparable between Shapiro patterns 1 and 3. Auxological examination, assessment of bone age, and sexual maturation are crucial tools for accurate timing of surgery. Level of Evidence: Level IV, Prognostic Study Cite this article as: Petr K, Daniela Z, Radek M, Sarka P, Ivo M. Lower extremity length discrepancy solution by modified drilling epiphysiodesis and anthropological prediction methods: long-term results. Acta Orthop Traumatol Turc., 2024;58(3):155-160.
- 3 January 2024
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 58 (3) , 155-160
Open AccessLower extremity length discrepancy solution by modified drilling epiphysiodesis and anthropological prediction methods: long-term results
Objective: This study aimed to summarize our experience with modified drilling epiphysiodesis and prediction methods for accurate timing of surgery and to compare the results with those of recent work by other authors. Methods: The Macnicol and Gupta modified drilling technique was used. Distal femoral and/or proximal tibial permanent epiphysiodesis was performed in 42 children (21 boys, 21 girls; median age at surgery=12.6 years, age range=9.4-15.4 years) between 2004 and 2016. Based on the groundwork of previous studies, we developed an auxological prediction method. The limb length discrepancy (LLD) was assessed by clinical examination and verified by an x-ray of the hips when standing with blocks under the shorter leg. Results: The predicted shortening was 2.7 cm ± 1.1 cm. The final discrepancy after finishing skeletal growth was 0.5 ± 0.5 cm. In 26 patients (61.9%), equalization of both legs was achieved (0-0.5 cm). In 4 patients (9.5%), the remaining shortening was more than 1.0 cm. Shortening of an initially longer leg occurred in two patients (0.5 cm and 0.6 cm). Failure of growth plate arrest was observed in 1 patient. In another 3 patients, the efficacy of tibial epiphysiodesis was unsatisfactory. Minor complications occurred in 5 cases, but there was no evidence of angular deformity in the frontal and sagittal planes or proximal fibula overgrowth. Three patients (7.1%) returned to the operating room. Compared to published data, more patients achieved complete equalization of leg length. Conclusion: The results of this study verified the accuracy of the auxological prediction algorithm of LLD based on Shapiro’s findings. The surgical outcome is comparable between Shapiro patterns 1 and 3. Auxological examination, assessment of bone age, and sexual maturation are crucial tools for accurate timing of surgery. Level of Evidence: Level IV, Prognostic Study Cite this article as: Petr K, Daniela Z, Radek M, Sarka P, Ivo M. Lower extremity length discrepancy solution by modified drilling epiphysiodesis and anthropological prediction methods: long-term results. Acta Orthop Traumatol Turc., 2024;58(3):155-160.
- 28 March 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (5) , 499-504
Effect of transtibial prosthesis weight on the contralateral knee joint in relation to the risk of osteoarthritis
Background: Individuals with transtibial amputation place more load on the contralateral lower extremity. A higher adduction moment at the knee joint has been shown to have an effect on the risk of osteoarthritis. Objective: The aim of this study was to investigate the effect of weight-bearing of lower-limb prosthesis on the biomechanical parameters associated with the risk of contralateral knee osteoarthritis. Study design: Cross-sectional. Methods: The experimental group of 14 subjects with unilateral transtibial amputation (13 males). The mean age was 52.7 ± 14.2 years, height 175.6 ± 6.3 cm, weight 82.3 ± 12.5 kg, and duration of prosthesis use 16.5 ± 9.1 years. The control group consisted of 14 healthy subjects with identical anthropometric parameters. Dual emission X-ray absorptiometry was used to determine the weight of the amputated limb. For gait analysis, 10 Qualisys infrared cameras and a motion sensing system on 3 Kistler force platforms were used. Gait was analyzed with the original, lighter, commonly used prosthesis, as well as the prosthesis loaded to the original limb weight. Results: The gait cycle and kinetic parameters of the amputated and healthy limbs were more similar to those of the control group when using the weighted prosthesis. Conclusions: We recommend further research to more accurately specify the weight of the lower-limb prosthesis with respect to the prosthesis design and duration of use of the heavier prosthesis during the day.
- 28 March 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (5) , 499-504
Effect of transtibial prosthesis weight on the contralateral knee joint in relation to the risk of osteoarthritis
Background: Individuals with transtibial amputation place more load on the contralateral lower extremity. A higher adduction moment at the knee joint has been shown to have an effect on the risk of osteoarthritis. Objective: The aim of this study was to investigate the effect of weight-bearing of lower-limb prosthesis on the biomechanical parameters associated with the risk of contralateral knee osteoarthritis. Study design: Cross-sectional. Methods: The experimental group of 14 subjects with unilateral transtibial amputation (13 males). The mean age was 52.7 ± 14.2 years, height 175.6 ± 6.3 cm, weight 82.3 ± 12.5 kg, and duration of prosthesis use 16.5 ± 9.1 years. The control group consisted of 14 healthy subjects with identical anthropometric parameters. Dual emission X-ray absorptiometry was used to determine the weight of the amputated limb. For gait analysis, 10 Qualisys infrared cameras and a motion sensing system on 3 Kistler force platforms were used. Gait was analyzed with the original, lighter, commonly used prosthesis, as well as the prosthesis loaded to the original limb weight. Results: The gait cycle and kinetic parameters of the amputated and healthy limbs were more similar to those of the control group when using the weighted prosthesis. Conclusions: We recommend further research to more accurately specify the weight of the lower-limb prosthesis with respect to the prosthesis design and duration of use of the heavier prosthesis during the day.