Long Shao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Long Shao has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Danni Ai
Beijing Institute of Technology
13 shared publications - Deqiang Xiao
Beijing Institute of Technology
13 shared publications - Jian Yang
Beijing Institute of Technology
13 shared publications - Hong Song
Beijing Institute of Technology
12 shared publications - Jingfan Fan
Beijing Institute of Technology
12 shared publications - Tianyu Fu
Beijing Institute of Technology
11 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 36 (11) , 17403-17421
Sequential Differentiable Alignment-Based 2D–3D Optimal Gaussian Distribution Registration for Monocular Endoscopic Video AR Guidance
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 36 (11) , 17403-17421
Sequential Differentiable Alignment-Based 2D–3D Optimal Gaussian Distribution Registration for Monocular Endoscopic Video AR Guidance
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 36 (10) , 14447-14462
A Latent Diffusion Model With Spatial Attributes for 3D Reconstruction in Biplanar X-Ray Images
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 36 (10) , 14447-14462
A Latent Diffusion Model With Spatial Attributes for 3D Reconstruction in Biplanar X-Ray Images
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-13
Point-Supervised Coronary Semantic Segmentation in X-Ray Angiographic Images
Coronary semantic segmentation in X-ray angiography is essential for computer-aided diagnosis and treatment planning of coronary artery disease (CAD). Despite its importance, this task remains highly challenging due to the complex and interconnected vascular topology, as well as the similar visual characteristics among different branches, making dense pixel-level manual annotation difficult and labor-intensive. To alleviate this burden, we propose a point-supervised coronary semantic segmentation framework that significantly reduces annotation effort without compromising segmentation accuracy. The primary challenge of point label based supervision lies in the model's tendency to overfit sparse point labels, leading to limited generalization to pixel-level predictions. To enrich the supervision signals and stabilize the training process with the sparse point labels, we propose an adaptive foreground mask generation module and a region regularization strategy to ensure accurate semantic guidance while maximizing meaningful coverage of the vascular structures. To enhance coronary topology perception and branch differentiation, we propose a multi-task learning framework that jointly performs keypoint detection and coronary semantic segmentation through a shared feature extraction encoder and two task-specific decoders. The experimental results demonstrate that our point-supervised model achieves performance comparable to fully supervised model, and outperforms the existing state-of-the-art point-supervised semantic segmentation methods.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-13
Point-Supervised Coronary Semantic Segmentation in X-Ray Angiographic Images
Coronary semantic segmentation in X-ray angiography is essential for computer-aided diagnosis and treatment planning of coronary artery disease (CAD). Despite its importance, this task remains highly challenging due to the complex and interconnected vascular topology, as well as the similar visual characteristics among different branches, making dense pixel-level manual annotation difficult and labor-intensive. To alleviate this burden, we propose a point-supervised coronary semantic segmentation framework that significantly reduces annotation effort without compromising segmentation accuracy. The primary challenge of point label based supervision lies in the model's tendency to overfit sparse point labels, leading to limited generalization to pixel-level predictions. To enrich the supervision signals and stabilize the training process with the sparse point labels, we propose an adaptive foreground mask generation module and a region regularization strategy to ensure accurate semantic guidance while maximizing meaningful coverage of the vascular structures. To enhance coronary topology perception and branch differentiation, we propose a multi-task learning framework that jointly performs keypoint detection and coronary semantic segmentation through a shared feature extraction encoder and two task-specific decoders. The experimental results demonstrate that our point-supervised model achieves performance comparable to fully supervised model, and outperforms the existing state-of-the-art point-supervised semantic segmentation methods.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 1802-1816
SG-3DGS: Sequential Growing 3D Gaussian Splatting for Scene Reconstruction of Monocular Endoscope Video
The reconstruction of monocular endoscope video scenes is essential for enhancing the application and analysis of surgical endoscopic images. However, restricted by the narrow space of endoscopic movement and the obstruction of vision within cavities, it is difficult for most conventional methods to perform high-quality reconstruction. To address these challenges, a novel dynamic growing 3D gaussian splatting architecture is proposed to construct the 3D model of endoscopic scene without precomputed camera poses or Structure from Motion. Firstly, to establish spatial feature associations between interframes, a 2D-3D displacement fields are designed by utilizing dense feature matches and depth prediction. On this basis, a novel displacement field variational optimization is developed to obtain relative poses by minimizing the energy functional associated with field transformation. Secondly, to address the constraint of the endoscopic view, by gaussian sequential transformation and differential gradient field optimization, a novel Sequential Gaussian Growing Module is proposed to grow the local gaussian model sequentially. Finally, a novel Forward-Reconstruction&Backward-Optimization architecture is proposed to generate the global gaussian model. The evaluation is conducted on two public endoscopic datasets: Scared and C3VD. The experimental results demonstrate that the proposed method outperforms state-of-the-art methods in both quantitative metrics (PSNR, SSIM, LPIPS, ATE, RMSE, MAE) and qualitative comparisons. The project page is https://iheckzza.github.io/DG-3DGS/.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 1802-1816
SG-3DGS: Sequential Growing 3D Gaussian Splatting for Scene Reconstruction of Monocular Endoscope Video
The reconstruction of monocular endoscope video scenes is essential for enhancing the application and analysis of surgical endoscopic images. However, restricted by the narrow space of endoscopic movement and the obstruction of vision within cavities, it is difficult for most conventional methods to perform high-quality reconstruction. To address these challenges, a novel dynamic growing 3D gaussian splatting architecture is proposed to construct the 3D model of endoscopic scene without precomputed camera poses or Structure from Motion. Firstly, to establish spatial feature associations between interframes, a 2D-3D displacement fields are designed by utilizing dense feature matches and depth prediction. On this basis, a novel displacement field variational optimization is developed to obtain relative poses by minimizing the energy functional associated with field transformation. Secondly, to address the constraint of the endoscopic view, by gaussian sequential transformation and differential gradient field optimization, a novel Sequential Gaussian Growing Module is proposed to grow the local gaussian model sequentially. Finally, a novel Forward-Reconstruction&Backward-Optimization architecture is proposed to generate the global gaussian model. The evaluation is conducted on two public endoscopic datasets: Scared and C3VD. The experimental results demonstrate that the proposed method outperforms state-of-the-art methods in both quantitative metrics (PSNR, SSIM, LPIPS, ATE, RMSE, MAE) and qualitative comparisons. The project page is https://iheckzza.github.io/DG-3DGS/.
- 15 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (4) , 1352-1368
Pelvic Fracture Reduction Planning via Joint Shape-Intensity Reference
Pelvic fracture reduction planning is clinically critical yet technically demanding due to the complex anatomical structure of pelvis and the topological discontinuities introduced by fractures. Existing computer-assisted planning approaches dominantly rely on shape-based models, overlooking the rich CT intensity information that is essential for accurate and patient-specific planning. To address this limitation, we propose SIRDiff, a novel framework that incorporates anatomical shape and CT intensity information to generate biomechanically plausible reference models for pelvic fracture reduction planning. SIRDiff comprises three key components: 1) the structure-aware diffusion model to reconstruct the global anatomical structure, 2) the topology-adaptive structural conditioning strategy that maps fracture landmarks into a healthy anatomical graph domain for robust structure guidance, and 3) the detail-preserved autoencoder to ensure the fine-grained image reconstruction from latent representations. Additionally, SIRDiff adopts a multi-task learning approach to jointly predict the reference CT image and corresponding bone segmentation map, which enhances its potential for clinical application and ensures better anatomical consistency. Despite being trained exclusively on synthetic fracture data, SIRDiff shows the strong generalizability to real clinical cases and consistently outperforms existing methods across multiple clinically relevant evaluation metrics, demonstrating its potential as a robust and deployable solution for pelvic fracture reduction planning.
- 15 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (4) , 1352-1368
Pelvic Fracture Reduction Planning via Joint Shape-Intensity Reference
Pelvic fracture reduction planning is clinically critical yet technically demanding due to the complex anatomical structure of pelvis and the topological discontinuities introduced by fractures. Existing computer-assisted planning approaches dominantly rely on shape-based models, overlooking the rich CT intensity information that is essential for accurate and patient-specific planning. To address this limitation, we propose SIRDiff, a novel framework that incorporates anatomical shape and CT intensity information to generate biomechanically plausible reference models for pelvic fracture reduction planning. SIRDiff comprises three key components: 1) the structure-aware diffusion model to reconstruct the global anatomical structure, 2) the topology-adaptive structural conditioning strategy that maps fracture landmarks into a healthy anatomical graph domain for robust structure guidance, and 3) the detail-preserved autoencoder to ensure the fine-grained image reconstruction from latent representations. Additionally, SIRDiff adopts a multi-task learning approach to jointly predict the reference CT image and corresponding bone segmentation map, which enhances its potential for clinical application and ensures better anatomical consistency. Despite being trained exclusively on synthetic fracture data, SIRDiff shows the strong generalizability to real clinical cases and consistently outperforms existing methods across multiple clinically relevant evaluation metrics, demonstrating its potential as a robust and deployable solution for pelvic fracture reduction planning.
- 26 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. PP (00189294) , 1-12
Simultaneous Reconstruction and Tracking for Motion Correction in Image Guided Surgery
Objective: Optical tracking system (OTS) localizes the position of rigid surgical tools attached with retro-reflective markers in image-guided surgery (IGS). IGS uses marker-based probes to collect points per frame, or attaches a coordinate reference frame (CRF) on a 3D camera to indirectly measure the surface of patient. However, these measurement methods involve compressive deformation errors from probes or calibration errors from 3D camera to OTS. Methods: This paper designs a simultaneous reconstruction and tracking framework for the markered tools and markerless surfaces in the indoor environment without calibration between measurement devices and OTS. A synchronized near-infrared (NIR) digital light projector (DLP) is integrated with OTS, and projects phase-shifting fringe patterns to the target surface. Surgical tools and surface are simultaneously tracked in the same coordinate system of OTS. The reconstructed surface is then registered to CT image space and corrects the intraoperative motion for mixed reality guided surgery. Results: The proposed method is compared with conventional measurement methods using calibrated devices in image-patient registration experiments, and they are evaluated with target registration error (TRE). The TRE of the proposed method is 0.805$\pm$0.152 mm in quantitative phantom experiments and 1.328$\pm$0.318 mm in qualitative cadaveric specimen experiments respectively, achieving the best performance among comparison methods in the phantom experiments. Conclusion: It demonstrates that our approach has the ability to enhance the registration accuracy and efficiency of IGS due to the noncontact and uncalibrated tracking.
- 26 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. PP (00189294) , 1-12
Simultaneous Reconstruction and Tracking for Motion Correction in Image Guided Surgery
Objective: Optical tracking system (OTS) localizes the position of rigid surgical tools attached with retro-reflective markers in image-guided surgery (IGS). IGS uses marker-based probes to collect points per frame, or attaches a coordinate reference frame (CRF) on a 3D camera to indirectly measure the surface of patient. However, these measurement methods involve compressive deformation errors from probes or calibration errors from 3D camera to OTS. Methods: This paper designs a simultaneous reconstruction and tracking framework for the markered tools and markerless surfaces in the indoor environment without calibration between measurement devices and OTS. A synchronized near-infrared (NIR) digital light projector (DLP) is integrated with OTS, and projects phase-shifting fringe patterns to the target surface. Surgical tools and surface are simultaneously tracked in the same coordinate system of OTS. The reconstructed surface is then registered to CT image space and corrects the intraoperative motion for mixed reality guided surgery. Results: The proposed method is compared with conventional measurement methods using calibrated devices in image-patient registration experiments, and they are evaluated with target registration error (TRE). The TRE of the proposed method is 0.805$\pm$0.152 mm in quantitative phantom experiments and 1.328$\pm$0.318 mm in qualitative cadaveric specimen experiments respectively, achieving the best performance among comparison methods in the phantom experiments. Conclusion: It demonstrates that our approach has the ability to enhance the registration accuracy and efficiency of IGS due to the noncontact and uncalibrated tracking.
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (10) , 10148-10161
Landmark and Pose Prediction in Occluded Facial Point Cloud via Explicit Joint Feature Fusion Network
Facial point clouds collected in practical applications often suffer from pose variations and occlusion. Existing studies typically focus on either pose estimation or landmarks localization, neglecting to fully utilize the effective information from various facial features, thus limiting the improvement of prediction accuracy. Therefore, we propose an innovative 3D facial multi-task prediction network. The proposed network embeds the output of related tasks into feature extraction from the point level to the global level based on the physical dependencies between tasks. This facilitates explicit multi-task knowledge transfer, enabling the simultaneous prediction of facial landmarks, occlusion, and head pose. We introduce a training strategy based on posterior knowledge correction to iteratively refine and improve multi-task prediction results. Moreover, no single dataset provides annotations for all these tasks at once, so we synthesized a 3D landmarks, occlusion and pose (3D-LOP) dataset, which includes annotations for landmarks coordinates, occlusion probability, and head pose. The proposed method was compared with state-of-the-art methods on two public datasets and 3D-LOP. The landmarks localization accuracy improved by 7.1% on the two public datasets, and the pose estimation accuracy and stability on 3D-LOP improved by 28.5% and 32.7%, respectively. The performance on wild data also shows its potential in practical applications.
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (10) , 10148-10161
Landmark and Pose Prediction in Occluded Facial Point Cloud via Explicit Joint Feature Fusion Network
Facial point clouds collected in practical applications often suffer from pose variations and occlusion. Existing studies typically focus on either pose estimation or landmarks localization, neglecting to fully utilize the effective information from various facial features, thus limiting the improvement of prediction accuracy. Therefore, we propose an innovative 3D facial multi-task prediction network. The proposed network embeds the output of related tasks into feature extraction from the point level to the global level based on the physical dependencies between tasks. This facilitates explicit multi-task knowledge transfer, enabling the simultaneous prediction of facial landmarks, occlusion, and head pose. We introduce a training strategy based on posterior knowledge correction to iteratively refine and improve multi-task prediction results. Moreover, no single dataset provides annotations for all these tasks at once, so we synthesized a 3D landmarks, occlusion and pose (3D-LOP) dataset, which includes annotations for landmarks coordinates, occlusion probability, and head pose. The proposed method was compared with state-of-the-art methods on two public datasets and 3D-LOP. The landmarks localization accuracy improved by 7.1% on the two public datasets, and the pose estimation accuracy and stability on 3D-LOP improved by 28.5% and 32.7%, respectively. The performance on wild data also shows its potential in practical applications.