  • Unchecked Wall Vacuum Might Pose a Risk: An In Vitro Experimental Study on the Effects of Negative Wall Pressure on Suction Ureteral Access Sheaths—A PACE Group Study

    by Jorge Peña Lueza, Alejandra Bravo-Balado, Carlos Alonso Altez Fernández, Federico Zorzi, Aideen Madden, Luigi Candela, Marie Chicaud, Letizia Maria Ippolita Jannello, Stessy Kutchukian, Marie-Lou Letouche, et al.

    Introduction: While safe positive intrarenal pressure (IRP) thresholds during retrograde intrarenal surgery (RIRS) are well known, negative outlet wall pressure applied to Flexible and Navigable Suction Sheaths (FANS) remains uncharacterized. Objective: To evaluate IRP dynamics under varying irrigation heights and negative suction pressures, providing foundational data to support evidence-based protocols in suction-assisted endourology. Materials and Methods: A silicone kidney model was instrumented with an 11–13Fr/46 cm FANS and a 7.5Fr single-use flexible ureteroscope. Real-time IRP was measured via pressure wire during four sequential phases: irrigation (30 seconds), suction (30 seconds), simulated channel blockage (90 seconds), and unblocking (5 seconds). Four experimental groups evaluated combinations of different irrigation heights (40 and 100 cmH 2 O) and negative pressures (−100 and −375 mmHg). Each combination was replicated three times, yielding 12 independent experiments. The primary outcome was the rate of IRP change (mmHg/s) during unblocking, and the secondary outcome was the maximum IRP observed during blockage. Data were analyzed using one-way ANOVA with Tukey’s post hoc test ( p < 0.05). Results: During unblocking, −375 mmHg suction produced significantly faster IRP reduction than −100 mmHg across all subgroups (mean differences 7.6–10.45 mmHg/s, p < 0.05). During blockage, 100 cmH 2 O irrigation generated significantly higher peak pressures than 40 cmH 2 O (mean differences 7.97–18.37 mmHg, p < 0.05). The combination of high irrigation pressure and high negative suction resulted in the most extreme and rapid pressure fluctuations, with changes occurring within fractions of 10-milliseconds. Conclusions: Negative outlet wall pressure significantly influences IRP dynamics during RIRS with FANS, producing rapid and extreme pressure changes. Pressure changes may occur on a timescale that could challenge manual recognition and corrective intervention. Standardized pressure monitoring and automated control systems might become a promising approach to ensuring patient safety during suction-assisted endourology.

  • In vitro evaluation of the new holmium:yttrium‐aluminium‐garnet laser with Magneto technology on behalf of the Progress and Collaboration in Endourology ( PACE) group

    by Adèle Martin‐Illac, Marie Chicaud, Marie‐Lou Letouche, Stefano Moretto, Federico Zorzi, Alejandra Bravo‐Balado, Carlos Altez Fernandes, Alberto Quarà, Aideen Madden, Letizia Maria Ippolita Jannello, et al.

    Objectives: To evaluate the following characteristics of the holmium:yttrium‐aluminium‐garnet (Ho:YAG) laser with Magneto technology: pulse shape, shape and duration of the laser‐induced vapour bubble (VB), power loss over time, and the risk of fibre fracture (RFF). Methods: A 150 W Ho:YAG generator was characterised in vitro with Magneto technology. The pulse shape was measured using an oscilloscope. The pulse duration was measured to calculate the peak power (PP) using both a 200‐ and 550‐μm laser fibre (LF). VB were evaluated with a 200‐μm fibre using a high‐speed camera (8000 frames/s). Power loss over time was obtained at the fibre tip before and after 30 s, then 1 min of continuous laser activation in saline solution and in contact with BegoStone® (BEGO GmbH & Co., Bremen, Germany). Power loss was evaluated using LFs with core diameters of 200, 365, and 550 μm. RFF was tested after 5 min of continuous laser activation or until LF fracture with different laser settings and LF bending radii (0.45, 0.6, 0.9 cm) using a 200‐μm LF. Results: The Ho:YAG laser with the Magneto technology possesses a quasi‐rectangular waveform with extended pulse durations ranging between 0.7 and 1.7 ms and limited PPs between a mean (standard deviation) of 513.4 (23.3) to 1149.7 (6.9) W that increase proportionally with power. However, multiple spikes were observed within each pulse, precluding a perfectly linear plateau. Regarding VB, it was significantly wider with the 550‐μm LF compared to the 200‐μm LF. Conversely, the VB duration was significantly longer with the 200‐μm LF. A consistent initial power loss was observed in normal saline of 13–28.0% across all LF diameters, which progressed during continuous activation of up to 1 min. This power degradation was more pronounced on synthetic BegoStone. No LF fractures were observed under the tested experimental conditions. Conclusion: The new Ho:YAG laser with Magneto technology appears to be a promising compromise between conventional Ho:YAG and thulium fibre laser, owing to its pulse profile with a limited PP.

  • Size matters: an in vitro evaluation of flexible vacuum-assisted ureteral access sheaths

    by Aideen Madden, Carlos Altez, Jordi Peña Lueza, Johan Cabrera, Alberto Quarà, Stefano Moretto, Răzvan-Ionut Popescu, Mariela Corrales, Olivier Traxer

    Suction in retrograde-intrarenal surgery (RIRS) has been the focus of ongoing innovation. Expanding ranges of flexible vacuum-assisted ureteric access sheaths (FV-UAS) combined with single-use digital flexible ureteroscopes (SU-DFU) produce many potential combinations. This study aims to evaluate the efficacy of these combinations in clearing stone fragments. Three different models of flexible vacuum-assisted ureteric access sheaths were tested: Clear Petra™ (8.5/9.5Fr, 10-12Fr, 12-14Fr), YiGao™ (10-12Fr, 12-14Fr) and Innovex™ (10-12Fr, 12-14Fr). A total of 6 ratio of endoscope-to-sheath diameters (RESDs) (0.53, 0.63, 0.74, 0.79, 0.88 and 0.95) were assessed by using three different single-use digital flexible ureteroscopes (6.3Fr Hugemed™, 7.5Fr Pusen™, 9.5Fr Lithovue™). Two techniques, continuous in-scope suction and pull-out with suction were tested across 5 dust size ranges (63–125, 125–250, 250–500 µm and 0.5–1 mm, 1–2 mm). A combination resulting in a ratio of endoscope-to-sheath diameter of 0.53 offered the best range, with up to 2 mm fragments aspirated with equal success by either method. Maximal stone clearance rates at 10.2 g/min were achieved with the combination of a 7.5Fr Pusen™ with 12-14F flexible vacuum-assisted ureteric access sheath, with a ratio of endoscope-to-sheath diameter of 0.63 using continuous in-scope suction for fragments 125–250 µm. Continuous in-scope suction emerges as the dominant technique for smaller stone fragments and pull-out with suction as dominant or equivalent for greater fragment sizes. The ratio of endoscope-to-sheath diameter is not the only factor critical to improving stone-free rates. Technique should be adapted according to estimated stone fragment size.


  • Direct in-scope suction: an in vitro evaluation of a single use flexible ureteroscope with integrated suction capability

    by Aideen Madden, Carlos Altez, Jordi Peña Lueza, Răzvan-Ionut Popescu, Johan Cabrera, Mariela Corrales, Olivier Traxer

    Purpose To evaluate the stone clearance rate and limitations of a novel integrated suction capability within a single-use flexible ureteroscope according to stone particle size. Methods Varying sized stone particles were created using a stone phantom (Begostone Plus, Bego ©, Lincoln, RI, USA). Particle size ranged as follows: 63–125 µm, 125–250 µm, 250–500 µm, 500 µm- 1 mm and 1–2 mm. These were mixed with Normal saline (0.9%) to mimic in vivo conditions. The suction enabled single-use flexible ureteroscope (Pusen, Zhuhai, China) was used to aspirate stone fragments in three trials. Firstly, aspiration of 5 g of each dust range was attempted. Secondly, a direct comparison of the integrated suction to a manual syringe technique was applied to 1 g of each size range. Finally, aspiration was applied to 5 g of a heterogenous 1:1:1:1:1 mixture. Endoscopic clearance rate (g/min) and number of blockages were recorded. Each challenge was repeated three times. Results The integrated suction cleared 100% of dust < 250 µm. Endoscopic clearance rates were significantly faster than manual aspiration (3.01 g/min versus 0.41 g/min) for dust between 125 and 250 µm (p = 0.008). Complete endoscopic clearance by 180 s (without encountering test limiting blockages) was unsuccessful for particles > 250 µm. Clearance rates were greatly limited by stone particle size heterogeneity above 250 µm, to 0.09 g/min. Conclusion This technology works better in vitro than previously DISS evaluated methods when challenged by stone dust < 250 µm. However, this adaptation is significantly challenged in the presence of stone dust particles > 250 µm.