XZXiang Zhang

Xiang Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiang Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deadbeat Predictive Current Control of DC-Biased-VRM Based on Extended State Observer With Coupling Disturbance Compensation

    by Zixiang Yu, Xiang Zhang, Jiwen Zhao, Yuhang Chen, Zhenbao Pan, Lijun Wang

    This article proposes a deadbeat predictive current control (DPCC) of dc-biased Vernier reluctance machine (dc-biased-VRM) based on extended state observer (ESO) with coupling disturbance compensation to improve the dynamic response and disturbance resistance ability of the control system. Firstly, the DPCC strategy was introduced into dc-biased-VRM, and the ESO-based DPCC method that ignores coupling was obtained. On this basis, the impacts of parameter mismatch and coupling disturbance of dc-biased-VRM on DPCC are analyzed, and an ESO with coupling disturbance compensation is proposed, which can swiftly compensate the disturbances arising from parameter mismatch and coupling effects. Furthermore, a quasi-resonant controller was introduced to suppress the harmonic current of the machine. Ultimately, the accuracy of current prediction and the dynamic response ability of current were improved, and this proposed strategy has a better ability to resist disturbances. Finally, by comparing the experimental results of the proposed strategy with those of the conventional one, the conclusion of this article was verified.


  • Alternate Subhexagonal Center Dual-Inverter PWM Scheme for Open-End Winding DC-Biased-VRM Drive Using Adjustable Zero Voltage Vector With Dead-Time Effect Compensation

    by Zixiang Yu, Yuhang Chen, Jiwen Zhao, Xiang Zhang, Xingyuan Zhou

    This paper proposes an alternate sub-hexagonal center dual-inverter PWM scheme for open-end winding DC-biased vernier reluctance machine (DC-biased-VRM) drive using novel adjustable zero voltage vector to reduce inverter loss. The alternate sub-hexagonal center scheme is utilized to assure the regulation of AC voltage, a novel adjustable zero voltage vector strategy is proposed to reconfigure the zero-sequence voltage, and realize the real-time adjustment of zero-sequence current. In addition, the dead zone distortion of the proposed scheme is analyzed, and a dead-time effect compensation strategy is investigated on the basis of the proposed PWM scheme to suppress the dead zone distortion. Furthermore, an average zero voltage action time control strategy is associated with the adjustable voltage vector, the maximum linear modulation range is guaranteed when the voltage utilization is close to the limit, so as to improve the machine speed range. Finally, prototype experiments have confirmed the efficacy of the proposed scheme, offering an efficient approach to enhancing the performance and operation range.


  • Improved Harmonic Current Injection Control Strategy for DC-Biased-VRM Based on Current Orthogonal Component Distribution to Enhance Output Torque

    by Xiang Zhang, Jiwen Zhao, Zixiang Yu, Zhenbao Pan

    This article proposes an improved harmonic current injection control strategy for dc-biased Vernier reluctance machine based on current orthogonal component distribution to enhance output torque, thereby improving the output efficiency of the machine. The effect of the interaction between the harmonic current and the inductance on average torque of the machine is analyzed. Then, a current distribution ratio with the maximum torque/current ratio is given, which can effectively increase the output torque of the machine. Based on this current ratio, a novel distribution method of harmonic current orthogonal component is proposed to provide reference value of harmonic current injection. Furthermore, in order to realize the precise injection control of amplitude and angle of harmonic current, a harmonic current orthogonal component tracking strategy with advanced angle compensation is proposed. The improved harmonic current injection control strategy presents advantages of high current control accuracy and wide applicable speed range. In addition, the parameter design of the method is relatively simple. Finally, the conclusion is verified by experiments.