LTLiangjie Tu

Liangjie Tu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liangjie Tu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Bingfei Fan

    College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, China

    2 shared publications
  • Guanjun Bao

    College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China

    2 shared publications
  • Shibo Cai

    School of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China

    2 shared publications
  • Tao Liu

    State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China

    2 shared publications
  • Bowen Lv

    College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, China

    1 shared publication
  • Kewen Zhang

    College of Mechanical Engineering and the Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, China

    1 shared publication

Latest Publications

  • Predicting Paretic Gait Trajectories Using sEMG With the ISSA-CNN-SVR Model

    by Liangjie Tu, Kewen Zhang, Mingyu Du, Guanjun Bao, Tao Liu, Bingfei Fan, Shibo Cai

    The continuous prediction of the desired gait trajectory of the paretic leg is a key task for the lower limb rehabilitation robot to assist the coordinated motion of the healthy and paretic legs of stroke patients, which has important research significance. In this paper, we propose a continuous prediction method for the desired gait trajectory of the paretic leg based on the sEMG signal of the healthy leg. In this method, an ISSA-CNN-SVR cascade network prediction model is designed. Based on this model, the mapping relationship between the sEMG signal of the healthy leg and the hip and knee joint angle of the paretic leg is established. The model input is the 8-channel sEMG signal of the healthy leg in the current instantaneous moment, and the output is the desired gait trajectory (hip and knee joint angle trajectories) of the paretic leg in the instantaneous moment after 100 ms. We recruited eight healthy participants for the validation experiments. Results indicate that the proposed method can continuously and smoothly predict the hip and knee joint angle trajectories of the paretic leg for the instantaneous moment after 100 ms based on the sEMG signal of the healthy leg and the ISSA-CNN-SVR model. The average RMSE of the predicted hip and knee joint angle trajectories of the paretic leg are 4.643° and 6.845°, with average R 2 being 0.855 and 0.857, respectively, demonstrating a high level of fitting. Therefore, this study is of great significance to improve the gait coordination of the healthy and paretic legs of robot-assisted stroke patients in the process of rehabilitation training.


  • Prediction of Continuous Joint Angles of the Lower Limb Based on sEMG by Using the ISSA-HKELM Algorithm

    by Liangjie Tu, Bingfei Fan, Mingyu Du, Guanjun Bao, Bowen Lv, Wenjie Mao, Tao Liu, Shibo Cai

    Continuous prediction of limb joint angles is a vital task in exoskeleton robot motion control. This paper introduces a method for continuous prediction of hip and knee joint angles based on a wearable sEMG signal acquisition system and the ISSA-HKELM prediction model. We first developed a novel wearable 8-channel lower limb sEMG signal collection system and then proposed an ISSA-HKELM prediction model, which is a hybrid kernel extreme learning machine with autonomous hyper-parameter optimization using an improved sparrow search algorithm. Using this model, we established a mapping relationship between sEMG signals and joint angles. The input of the model is the 8-channel sEMG signal at the current moment, and the output is the hip and knee angles at a specified time intervals in the future. We recruited eight healthy participants for the validation experiments. Results indicate that the developed wearable sEMG signal acquisition system and the proposed ISSA-HKELM model can achieve continuous prediction of hip and knee joint angles up to 80 ms in advance. The average RMSE for hip and knee joint angles are 4.61° and 5.95°, with average R2 of 0.902 and 0.848, respectively, demonstrating a high level of fitting. Therefore, this method effectively enables advance prediction of limb movement, and significantly enhancing real-time responsiveness and adaptability in human-robot interaction motion control.