Mohsen Romeshkani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohsen Romeshkani has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Jürgen Müller
Institute of Geodesy, Leibniz University Hannover, Hannover, Germany
7 shared publications - Manuel Schilling
Institute for Satellite Geodesy and Inertial Sensing, German Aerospace Center (DLR), Hannover, Germany
5 shared publications - Annike Knabe
Institute of Geodesy, Leibniz University Hannover, Hannover, Germany
4 shared publications Sahar Ebadi
3 shared publications- Alexey Kupriyanov
Institute of Geodesy, Leibniz University Hannover, Hannover, Germany
2 shared publications Annike Knabe
Leibniz Univ Hannover, Inst Geodesy, Schneiderberg 50, D-30167 Hannover, Germany
2 shared publications
Latest Publications
- Open Access
- 13 October 2026
- Published by Copernicus GmbH
Machine Learning-Based Accelerometer Transplantation for GRACE and Future Quantum-Enabled Satellite Gravimetry
Accurate and continuous determination of the Earth’s time-variable gravity field is essential for monitoring mass redistribution related to hydrological, climatic, and geodynamic processes. GRACE and GRACE Follow-On (GRACE-FO) have demonstrated the high capability of low-low satellite-to-satellite tracking (LL-SST) technique for global gravity field recovery; however, the resulting accuracy strongly depends on the quality of the involved sensors, e.g., the accelerometers (ACC) used to account for non-gravitational forces. While conventional electrostatic accelerometers (EA) provide high short-term sensitivity, their performance is affected by drift at low frequencies. Emerging quantum-based sensors, particularly Cold Atom Interferometry (CAI) accelerometers, offer promising characteristics to overcome the later issue for future satellite gravimetry.This study investigates accelerometer observation transplantation to reduce the number of accelerometers required onboard future satellite gravimetry missions. Different configurations involving EA, CAI, and hybrid EA–CAI accelerometers are evaluated using closed-loop LL-SST simulations. Four scenarios are considered, ranging from the conventional EA-only configuration to an ideal configuration in which both satellites carry complete hybrid accelerometers. Particular attention is given to a reduced-sensor configuration in which EA and CAI observations are transplanted between satellites, enabling a virtual hybrid configuration with fewer physical accelerometers.In addition to conventional analytical transplantation, machine-learning (ML) approaches, including Multilayer Perceptron (MLP), Long Short-Term Memory (LSTM), and Bidirectional LSTM (BiLSTM), are investigated to improve the transplanted accelerometer observations. The configurations are evaluated directly at the gravity-field level. The results show that the complete dual-hybrid configuration provides the highest performance, while the ML-based reduced-sensor configuration significantly improves upon analytical transplantation and approaches the performance of the ideal hybrid configuration.The data-driven transplantation concept is further assessed using real GRACE accelerometer observations. During GRACE and GRACE-FO, accelerometer degradation or failure affected the availability and quality of non-gravitational acceleration observations, requiring their reconstruction. An LSTM-based dynamic mapping using GRACE-A accelerometer observations and auxiliary non-gravitational force models is developed to reconstruct GRACE-B accelerations. The reconstructed observations are introduced into monthly gravity field recovery and evaluated through degree variances, equivalent-water-height representations, and RMS variability over the oceans. The results demonstrate successful reconstruction of the missing accelerometer information and improvements in the resulting monthly gravity field solutions. The same framework can also be adapted to degraded accelerometer observations in GRACE-FO.Overall, the results demonstrate the potential of ML for recovering missing or degraded accelerometer observations and enabling reduced-sensor architectures for future satellite gravimetry. Combining quantum sensing, accelerometer transplantation, and ML provides a promising pathway toward high-performance, less complex, and potentially more cost-effective future gravimetry missions.Keywords: Satellite gravimetry; GRACE; GRACE-FO; accelerometer transplantation; Cold Atom Interferometry; hybrid accelerometers; machine learning; time-variable gravity field.Acknowledgement: This work was supported by Germany’s Excellence Strategy – EXC-2123 “QuantumFrontiers” – 390837967.
- 13 October 2026
- Published by Copernicus GmbH
Open AccessMachine Learning-Based Accelerometer Transplantation for GRACE and Future Quantum-Enabled Satellite Gravimetry
Accurate and continuous determination of the Earth’s time-variable gravity field is essential for monitoring mass redistribution related to hydrological, climatic, and geodynamic processes. GRACE and GRACE Follow-On (GRACE-FO) have demonstrated the high capability of low-low satellite-to-satellite tracking (LL-SST) technique for global gravity field recovery; however, the resulting accuracy strongly depends on the quality of the involved sensors, e.g., the accelerometers (ACC) used to account for non-gravitational forces. While conventional electrostatic accelerometers (EA) provide high short-term sensitivity, their performance is affected by drift at low frequencies. Emerging quantum-based sensors, particularly Cold Atom Interferometry (CAI) accelerometers, offer promising characteristics to overcome the later issue for future satellite gravimetry.This study investigates accelerometer observation transplantation to reduce the number of accelerometers required onboard future satellite gravimetry missions. Different configurations involving EA, CAI, and hybrid EA–CAI accelerometers are evaluated using closed-loop LL-SST simulations. Four scenarios are considered, ranging from the conventional EA-only configuration to an ideal configuration in which both satellites carry complete hybrid accelerometers. Particular attention is given to a reduced-sensor configuration in which EA and CAI observations are transplanted between satellites, enabling a virtual hybrid configuration with fewer physical accelerometers.In addition to conventional analytical transplantation, machine-learning (ML) approaches, including Multilayer Perceptron (MLP), Long Short-Term Memory (LSTM), and Bidirectional LSTM (BiLSTM), are investigated to improve the transplanted accelerometer observations. The configurations are evaluated directly at the gravity-field level. The results show that the complete dual-hybrid configuration provides the highest performance, while the ML-based reduced-sensor configuration significantly improves upon analytical transplantation and approaches the performance of the ideal hybrid configuration.The data-driven transplantation concept is further assessed using real GRACE accelerometer observations. During GRACE and GRACE-FO, accelerometer degradation or failure affected the availability and quality of non-gravitational acceleration observations, requiring their reconstruction. An LSTM-based dynamic mapping using GRACE-A accelerometer observations and auxiliary non-gravitational force models is developed to reconstruct GRACE-B accelerations. The reconstructed observations are introduced into monthly gravity field recovery and evaluated through degree variances, equivalent-water-height representations, and RMS variability over the oceans. The results demonstrate successful reconstruction of the missing accelerometer information and improvements in the resulting monthly gravity field solutions. The same framework can also be adapted to degraded accelerometer observations in GRACE-FO.Overall, the results demonstrate the potential of ML for recovering missing or degraded accelerometer observations and enabling reduced-sensor architectures for future satellite gravimetry. Combining quantum sensing, accelerometer transplantation, and ML provides a promising pathway toward high-performance, less complex, and potentially more cost-effective future gravimetry missions.Keywords: Satellite gravimetry; GRACE; GRACE-FO; accelerometer transplantation; Cold Atom Interferometry; hybrid accelerometers; machine learning; time-variable gravity field.Acknowledgement: This work was supported by Germany’s Excellence Strategy – EXC-2123 “QuantumFrontiers” – 390837967.
- Open Access
- 22 September 2026
- Published by Springer Nature in Journal of Geodesy
- Vol. 100 (10) , 83
Machine learning algorithms for transplanting accelerometer observations in future satellite gravimetry missions
Accurate and continuous monitoring of Earth’s gravity field is essential for tracking mass redistribution processes linked to climate variability, hydrological cycles, and geodynamic phenomena. While the GRACE and GRACE Follow-On (GRACE-FO) missions have set the benchmark for satellite gravimetry using low–low satellite-to-satellite tracking (LL-SST), the precision of gravity field recovery still strongly depends on the quality of accelerometer (ACC) performance. Traditional electrostatic accelerometers (EA) face limitations that can hinder mission outcomes, prompting exploration of advanced sensor technologies and data recovery techniques. This study presents a systematic evaluation of accelerometer data transplantation (i.e., the reconstruction and transfer of non-gravitational acceleration measurements between satellites) using novel accelerometer configurations, including Cold Atom Interferometry (CAI) accelerometers and hybrid EA-CAI setups, and applying both analytical and machine learning-based methods. Using comprehensive closed-loop LL-SST simulations, we compare four scenarios ranging from the conventional EA-only setup to ideal dual hybrid configurations, with a particular focus on the performance of transplant-based approaches using different neural network approaches. Our results show that the dual hybrid configuration provides the most accurate gravity field retrieval. However, the transplant-based hybrid setup, particularly when supported by machine learning (ML), emerges as a robust and cost-effective alternative, achieving comparable performance while significantly reducing the need for high-precision accelerometers across the constellation, thereby lowering mission costs and system complexity. These findings highlight the promise of combining quantum sensor technology and data-driven transplantation for future satellite gravimetry missions, paving the way for improved global monitoring of Earth’s dynamic gravity field.
- 22 September 2026
- Published by Springer Nature in Journal of Geodesy
- Vol. 100 (10) , 83
Open AccessMachine learning algorithms for transplanting accelerometer observations in future satellite gravimetry missions
Accurate and continuous monitoring of Earth’s gravity field is essential for tracking mass redistribution processes linked to climate variability, hydrological cycles, and geodynamic phenomena. While the GRACE and GRACE Follow-On (GRACE-FO) missions have set the benchmark for satellite gravimetry using low–low satellite-to-satellite tracking (LL-SST), the precision of gravity field recovery still strongly depends on the quality of accelerometer (ACC) performance. Traditional electrostatic accelerometers (EA) face limitations that can hinder mission outcomes, prompting exploration of advanced sensor technologies and data recovery techniques. This study presents a systematic evaluation of accelerometer data transplantation (i.e., the reconstruction and transfer of non-gravitational acceleration measurements between satellites) using novel accelerometer configurations, including Cold Atom Interferometry (CAI) accelerometers and hybrid EA-CAI setups, and applying both analytical and machine learning-based methods. Using comprehensive closed-loop LL-SST simulations, we compare four scenarios ranging from the conventional EA-only setup to ideal dual hybrid configurations, with a particular focus on the performance of transplant-based approaches using different neural network approaches. Our results show that the dual hybrid configuration provides the most accurate gravity field retrieval. However, the transplant-based hybrid setup, particularly when supported by machine learning (ML), emerges as a robust and cost-effective alternative, achieving comparable performance while significantly reducing the need for high-precision accelerometers across the constellation, thereby lowering mission costs and system complexity. These findings highlight the promise of combining quantum sensor technology and data-driven transplantation for future satellite gravimetry missions, paving the way for improved global monitoring of Earth’s dynamic gravity field.
- Open Access
- 31 December 2025
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 13 (1)
Accelerometer Data Transplant for Future Satellite Gravimetry
Accurate monitoring of the Earth's gravity field is crucial for understanding mass redistribution processes related to climate change, hydrology, and geodynamics. The Gravity Recovery and Climate Experiment (GRACE) and its successor, GRACE Follow‐On (GRACE‐FO), have provided invaluable satellite gravimetry data through low‐low satellite‐to‐satellite tracking (LL‐SST). However, the precision of gravity field recovery is significantly affected not only by data gaps in the accelerometer (ACC) measurements, but also by potential failures or limitations in their performance. To mitigate these issues, accelerometer data transplantation has been employed, leveraging the similarity in non‐gravitational accelerations experienced by both satellites. This study presents an in‐depth assessment of transplant noise and evaluates advanced accelerometer configurations, including Cold Atom Interferometry (CAI) accelerometers and hybrid electrostatic‐quantum accelerometer setups for future satellite gravimetry missions. Through closed‐loop LL‐SST simulations, we compare four different accelerometer configurations, ranging from conventional electrostatic accelerometers (EAs) to fully hybrid CAI‐EA setups. Results indicate that a dual hybrid accelerometer configuration offers the highest accuracy in gravity field recovery, while a transplant‐based hybrid approach significantly enhances the performance of non‐gravitational force modeling without requiring additional instrumentation. The findings underscore the potential of quantum accelerometery and transplant methodologies for future satellite gravimetry missions, offering a cost‐effective solution to improve gravity field recovery, while benefitting from new sensor types.
- 31 December 2025
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 13 (1)
Open AccessAccelerometer Data Transplant for Future Satellite Gravimetry
Accurate monitoring of the Earth's gravity field is crucial for understanding mass redistribution processes related to climate change, hydrology, and geodynamics. The Gravity Recovery and Climate Experiment (GRACE) and its successor, GRACE Follow‐On (GRACE‐FO), have provided invaluable satellite gravimetry data through low‐low satellite‐to‐satellite tracking (LL‐SST). However, the precision of gravity field recovery is significantly affected not only by data gaps in the accelerometer (ACC) measurements, but also by potential failures or limitations in their performance. To mitigate these issues, accelerometer data transplantation has been employed, leveraging the similarity in non‐gravitational accelerations experienced by both satellites. This study presents an in‐depth assessment of transplant noise and evaluates advanced accelerometer configurations, including Cold Atom Interferometry (CAI) accelerometers and hybrid electrostatic‐quantum accelerometer setups for future satellite gravimetry missions. Through closed‐loop LL‐SST simulations, we compare four different accelerometer configurations, ranging from conventional electrostatic accelerometers (EAs) to fully hybrid CAI‐EA setups. Results indicate that a dual hybrid accelerometer configuration offers the highest accuracy in gravity field recovery, while a transplant‐based hybrid approach significantly enhances the performance of non‐gravitational force modeling without requiring additional instrumentation. The findings underscore the potential of quantum accelerometery and transplant methodologies for future satellite gravimetry missions, offering a cost‐effective solution to improve gravity field recovery, while benefitting from new sensor types.
- Open Access
- 28 April 2025
- Published by Wiley
Accelerometer data transplant for future satellite gravimetry
Accurate monitoring of the Earth’s gravity field is crucial for understanding mass redistribution processes related to climate change, hydrology, and geodynamics. The Gravity Recovery and Climate Experiment (GRACE) and its successor, GRACE Follow-On (GRACE-FO), have provided invaluable satellite gravimetry data through low-low satellite-to-satellite tracking (LL-SST). However, the precision of gravity field recovery is significantly affected not only by data gaps in the accelerometer (ACC) measurements, but also by potential failures or limitations in their performance. To mitigate these issues, accelerometer data transplantation has been employed, leveraging the similarity in non-gravitational accelerations experienced by both satellites. This study presents an in-depth assessment of transplant noise and evaluates advanced accelerometer configurations, including Cold Atom Interferometry (CAI) accelerometers and hybrid electrostatic-quantum accelerometer setups for future satellite gravimetry missions. Through closed-loop LL-SST simulations, we compare four different accelerometer configurations, ranging from conventional electrostatic accelerometers (EAs) to fully hybrid CAI-EA setups. Results indicate that a dual hybrid accelerometer configuration offers the highest accuracy in gravity field recovery, while a transplant-based hybrid approach significantly enhances the performance of non-gravitational force modelling without requiring additional instrumentation. The findings underscore the potential of quantum accelerometery and transplant methodologies for future satellite gravimetry missions, offering a cost-effective solution to improve gravity field recovery, while benefitting from new sensor types.
- 28 April 2025
- Published by Wiley
Open AccessAccelerometer data transplant for future satellite gravimetry
Accurate monitoring of the Earth’s gravity field is crucial for understanding mass redistribution processes related to climate change, hydrology, and geodynamics. The Gravity Recovery and Climate Experiment (GRACE) and its successor, GRACE Follow-On (GRACE-FO), have provided invaluable satellite gravimetry data through low-low satellite-to-satellite tracking (LL-SST). However, the precision of gravity field recovery is significantly affected not only by data gaps in the accelerometer (ACC) measurements, but also by potential failures or limitations in their performance. To mitigate these issues, accelerometer data transplantation has been employed, leveraging the similarity in non-gravitational accelerations experienced by both satellites. This study presents an in-depth assessment of transplant noise and evaluates advanced accelerometer configurations, including Cold Atom Interferometry (CAI) accelerometers and hybrid electrostatic-quantum accelerometer setups for future satellite gravimetry missions. Through closed-loop LL-SST simulations, we compare four different accelerometer configurations, ranging from conventional electrostatic accelerometers (EAs) to fully hybrid CAI-EA setups. Results indicate that a dual hybrid accelerometer configuration offers the highest accuracy in gravity field recovery, while a transplant-based hybrid approach significantly enhances the performance of non-gravitational force modelling without requiring additional instrumentation. The findings underscore the potential of quantum accelerometery and transplant methodologies for future satellite gravimetry missions, offering a cost-effective solution to improve gravity field recovery, while benefitting from new sensor types.
- Open Access
- 3 December 2024
- Published by Elsevier in Advances In Space Research
- Vol. 75 (2) , 1653-1664
Quantum gravimetry for future satellite gradiometry
- 3 December 2024
- Published by Elsevier in Advances In Space Research
- Vol. 75 (2) , 1653-1664
Open AccessQuantum gravimetry for future satellite gradiometry
- Open Access
- 31 October 2024
- Published by Springer Nature
- p. 187-197
Analysis of Novel Sensors and Satellite Formation Flights for Future Gravimetry Missions
Accelerometers (ACCs) in low-low satellite-to-satellite gravimetry missions measure the non-gravitational forces acting on the spacecraft that have to be taken into account to derive the gravitational contribution in the distance variations. Multiple ACCs form a so-called gradiometer that measure the gravity gradient. In satellite gravimetry up to now, only electrostatic ACCs were used, which are one of the main instrumental limitations due to their error contribution at low frequencies, known as drift. In this paper, we compare the performance of electrostatic ACCs at low Earth orbits with other sensors, i.e. so-called Optical ACCs based on flight heritage of the LISA-Pathfinder mission, and theoretical ACC concepts, for example Cold Atom Interferometer (CAI) ACCs and hybridized sensors (combination of electrostatic and CAI ACCs) in terms of static gravity field recovery. Under our assumptions, in particular that high-frequency variations of the gravity field can be perfectly modeled and removed during gravity field recovery, the results may be limited in the future by the performance of the LRI. We also discuss the outcomes from the various novel satellite formation flights (SFF) that utilize two orbits that differ either by right ascension of the ascending node (RAAN) or by inclination in order to acquire ranging information in the cross-track direction. The closed-loop simulations from both scenarios showed significantly lower order of magnitude of the residuals w.r.t. reference gravity field than from the anticipated future performance of the solely in-line GRACE-like satellite pair. Moreover, these triple satellite formations provide better multi-directionality of the retrieved data, avoiding the North-South striping behavior. However, it is worth noting that in such formations significant modifications are needed in the satellite bus, ACC test mass readout, LRI beam steering mechanism, etc. in order to be capable of measuring the cross-track range changes at higher range rates w.r.t. in-line GRACE-like configuration. In addition, a substantial reduction of costs in building and launching only three satellites rather than four as in double-pair constellations could be an advantage for such formations.
- 31 October 2024
- Published by Springer Nature
- p. 187-197
Open AccessAnalysis of Novel Sensors and Satellite Formation Flights for Future Gravimetry Missions
Accelerometers (ACCs) in low-low satellite-to-satellite gravimetry missions measure the non-gravitational forces acting on the spacecraft that have to be taken into account to derive the gravitational contribution in the distance variations. Multiple ACCs form a so-called gradiometer that measure the gravity gradient. In satellite gravimetry up to now, only electrostatic ACCs were used, which are one of the main instrumental limitations due to their error contribution at low frequencies, known as drift. In this paper, we compare the performance of electrostatic ACCs at low Earth orbits with other sensors, i.e. so-called Optical ACCs based on flight heritage of the LISA-Pathfinder mission, and theoretical ACC concepts, for example Cold Atom Interferometer (CAI) ACCs and hybridized sensors (combination of electrostatic and CAI ACCs) in terms of static gravity field recovery. Under our assumptions, in particular that high-frequency variations of the gravity field can be perfectly modeled and removed during gravity field recovery, the results may be limited in the future by the performance of the LRI. We also discuss the outcomes from the various novel satellite formation flights (SFF) that utilize two orbits that differ either by right ascension of the ascending node (RAAN) or by inclination in order to acquire ranging information in the cross-track direction. The closed-loop simulations from both scenarios showed significantly lower order of magnitude of the residuals w.r.t. reference gravity field than from the anticipated future performance of the solely in-line GRACE-like satellite pair. Moreover, these triple satellite formations provide better multi-directionality of the retrieved data, avoiding the North-South striping behavior. However, it is worth noting that in such formations significant modifications are needed in the satellite bus, ACC test mass readout, LRI beam steering mechanism, etc. in order to be capable of measuring the cross-track range changes at higher range rates w.r.t. in-line GRACE-like configuration. In addition, a substantial reduction of costs in building and launching only three satellites rather than four as in double-pair constellations could be an advantage for such formations.
- Open Access
- 1 September 2024
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 11 (9)
The Benefits of Future Quantum Accelerometers for Satellite Gravimetry
We investigate the benefits of future quantum accelerometers based on cold atom interferometry (CAI) on current and upcoming satellite gravity mission concepts. These mission concepts include satellite‐to‐satellite tracking (SST) in a single‐pair (GRACE‐like) and double‐pair constellation as well as satellite gravity gradiometry (SGG, single satellite, GOCE‐like). Regarding instruments, four scenarios are considered: current‐generation electrostatic (GRACE‐, GOCE‐like), next‐generation electrostatic, conservative hybrid/CAI and optimistic hybrid/CAI. For SST, it is shown that temporal aliasing poses currently the dominating error source in simulated global gravity field solutions independent of the investigated instrument and constellation. To still quantify the advantages of CAI instruments on the gravity functional itself, additional simulations are performed where the impact of temporal aliasing is synthetically reduced. When neglecting temporal aliasing, future accelerometers in conjunction with future ranging instruments can substantially improve the retrieval performance of the Earth's gravity field (depending on instrument and constellation). These simulation results are further investigated regarding possible benefit for hydrological use cases where these improvements can also be observed (when omitting temporal aliasing). For SGG, it is demonstrated that, with realistic instrument assumptions, one is still mostly insensitive to time‐variable gravity and not competitive with the SST principle. However, due to the improved instrument sensitivity of quantum gradiometers compared to the GOCE mission, static gravity field solutions can be improved significantly.
- 1 September 2024
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 11 (9)
Open AccessThe Benefits of Future Quantum Accelerometers for Satellite Gravimetry
We investigate the benefits of future quantum accelerometers based on cold atom interferometry (CAI) on current and upcoming satellite gravity mission concepts. These mission concepts include satellite‐to‐satellite tracking (SST) in a single‐pair (GRACE‐like) and double‐pair constellation as well as satellite gravity gradiometry (SGG, single satellite, GOCE‐like). Regarding instruments, four scenarios are considered: current‐generation electrostatic (GRACE‐, GOCE‐like), next‐generation electrostatic, conservative hybrid/CAI and optimistic hybrid/CAI. For SST, it is shown that temporal aliasing poses currently the dominating error source in simulated global gravity field solutions independent of the investigated instrument and constellation. To still quantify the advantages of CAI instruments on the gravity functional itself, additional simulations are performed where the impact of temporal aliasing is synthetically reduced. When neglecting temporal aliasing, future accelerometers in conjunction with future ranging instruments can substantially improve the retrieval performance of the Earth's gravity field (depending on instrument and constellation). These simulation results are further investigated regarding possible benefit for hydrological use cases where these improvements can also be observed (when omitting temporal aliasing). For SGG, it is demonstrated that, with realistic instrument assumptions, one is still mostly insensitive to time‐variable gravity and not competitive with the SST principle. However, due to the improved instrument sensitivity of quantum gradiometers compared to the GOCE mission, static gravity field solutions can be improved significantly.
- Open Access
- 15 May 2023
- Published by Copernicus GmbH
Benefit of Quantum technology for future earth observation from space – gradiometry case
A big interest exists in geoscience disciplines to know the mass variations of the Earth with high resolution and accuracy. For monitoring climate change processes at the required level, it is essential to select the appropriate sensor technology and satellite missions. Future satellite missions will strongly depend on the advancement of novel technology and dedicated observation concepts of the Earth's gravitational field.The first objective of this study is to characterize various quantum and hybrid gradiometer concepts and to describe their respective error properties. As a result of their white noise behavior at low frequencies, Cold Atom Interferometry (CAI) accelerometers and gradiometers are perfectly suited as complementary methods to classical electrostatic concepts. Future gravity satellite missions could greatly benefit from accelerometers and gradiometers applying atom interferometry, alone or in some hybrid constellation. The comparison will demonstrate the differences in the spectral behavior as well as the mutual benefit of CAI-based and classical electrostatic gradiometers (as used in GOCE).Using simulated atom-interferometric and hybrid gradient measurements along one or more gradiometer axes in GOCE-like orbits, we determine the gravity field in spherical harmonics coefficients for the various cases and discuss the pros and cons of the selected concepts.We acknowledge the financial support by the DLR project Q-BAGS, ID 50WM2181 and DLR project QUANTGRAV, ID 50EE2220B.
- 15 May 2023
- Published by Copernicus GmbH
Open AccessBenefit of Quantum technology for future earth observation from space – gradiometry case
A big interest exists in geoscience disciplines to know the mass variations of the Earth with high resolution and accuracy. For monitoring climate change processes at the required level, it is essential to select the appropriate sensor technology and satellite missions. Future satellite missions will strongly depend on the advancement of novel technology and dedicated observation concepts of the Earth's gravitational field.The first objective of this study is to characterize various quantum and hybrid gradiometer concepts and to describe their respective error properties. As a result of their white noise behavior at low frequencies, Cold Atom Interferometry (CAI) accelerometers and gradiometers are perfectly suited as complementary methods to classical electrostatic concepts. Future gravity satellite missions could greatly benefit from accelerometers and gradiometers applying atom interferometry, alone or in some hybrid constellation. The comparison will demonstrate the differences in the spectral behavior as well as the mutual benefit of CAI-based and classical electrostatic gradiometers (as used in GOCE).Using simulated atom-interferometric and hybrid gradient measurements along one or more gradiometer axes in GOCE-like orbits, we determine the gravity field in spherical harmonics coefficients for the various cases and discuss the pros and cons of the selected concepts.We acknowledge the financial support by the DLR project Q-BAGS, ID 50WM2181 and DLR project QUANTGRAV, ID 50EE2220B.