Armando Perez-Silva
Research Subjects
Armando Perez-Silva has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Alex Pacheco-Bouthillier
Inst Cardiovasc Minima Invas, Guadalajara, Mexico
1 shared publication - Alicia Sale
Medtronic, Minneapolis, MN USA
1 shared publication Andrea Natale
Texas Cardiac Arrhythmia Institute, St David’s Medical Center , Austin
1 shared publication- Andrea Sarkozy
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, European Reference Networks Guard-Heart , Brussels
1 shared publication - Ante Anic
Department for Cardiovascular Diseases, University Hospital Center Split , Split
1 shared publication - Antonio Dello Russo
Arrhythmology Clinic Department, Azienda Ospedaliera Universitaria delle Marche , Ancona
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 12 April 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (6)
Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society
Pulsed field ablation has emerged as a novel non-thermal treatment modality with a distinct safety profile for the interventional treatment of atrial fibrillation. By inducing irreversible electroporation, pulsed field ablation achieves myocardial ablation while preserving surrounding structures such as nerves, vasculature, and the oesophagus. This European Heart Rhythm Association of the European Society of Cardiology scientific statement, endorsed by major international societies, reviews the biophysics, technology, clinical evidence, workflow, safety, and training aspects of pulsed field ablation. Randomized trials demonstrate comparable efficacy to radiofrequency and cryoballoon ablation, with advantages in safety and efficiency. The statement provides practical advice for clinical implementation and operator training and identifies key gaps in evidence and priorities for future research and innovation.
- 12 April 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (6)
Top Cited PapersOpen AccessPulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society
Pulsed field ablation has emerged as a novel non-thermal treatment modality with a distinct safety profile for the interventional treatment of atrial fibrillation. By inducing irreversible electroporation, pulsed field ablation achieves myocardial ablation while preserving surrounding structures such as nerves, vasculature, and the oesophagus. This European Heart Rhythm Association of the European Society of Cardiology scientific statement, endorsed by major international societies, reviews the biophysics, technology, clinical evidence, workflow, safety, and training aspects of pulsed field ablation. Randomized trials demonstrate comparable efficacy to radiofrequency and cryoballoon ablation, with advantages in safety and efficiency. The statement provides practical advice for clinical implementation and operator training and identifies key gaps in evidence and priorities for future research and innovation.
- 2 September 2024
- Published by Medwave Estudios Limitada in Medwave
- Vol. 24 (08) , e2918
Electrophysiology lab efficiency using cryoballoon for pulmonary vein isolation in Latin America: A sub-analysis of the Cryo Global Registry Study
Objective Cryoballoon ablation for pulmonary vein isolation is a time-efficient procedure that can alleviate stress on electrophysiology lab resources. This analysis modeled the impact of cryoballoon ablation on electrophysiology lab operation using data from Latin America. Methods Data from centers in Argentina, Mexico, Colombia, and Chile of the were used as inputs for an electrophysiology lab efficiency simulation model. The model used the assumption that either two (today’s electrophysiology lab operations) or three (including electrophysiology lab operational changes) cryoballoon ablation procedures could be performed per day. The endpoints were the percentage of days that resulted in 1) overtime and 2) time left for an extra non-ablation electrophysiology procedure. Results Data from a total of 232 procedures from six Latin American centers were included in the analysis. The average electrophysiology lab occupancy time for all procedures in Latin America was 132 ± 62 minutes. In the Current Scenario (two procedures per day), 7.4% of simulated days resulted in overtime, and 81.4% had enough time for an extra electrophysiology procedure. In the Enhanced Productivity Scenario (three procedures per day), 16.4% of days used overtime, while 67.4% allowed time for an extra non-ablation electrophysiology procedure. Conclusions Using real-world, Latin American-specific data, we found that with operational changes, three ablation procedures could feasibly be performed daily, leaving time for an extra electrophysiology procedure on more than half of days. Thus, use of cryoballoon ablation is an effective tool to enhance electrophysiology lab efficiency in resource-constrained regions such as Latin America.
- 2 September 2024
- Published by Medwave Estudios Limitada in Medwave
- Vol. 24 (08) , e2918
Electrophysiology lab efficiency using cryoballoon for pulmonary vein isolation in Latin America: A sub-analysis of the Cryo Global Registry Study
Objective Cryoballoon ablation for pulmonary vein isolation is a time-efficient procedure that can alleviate stress on electrophysiology lab resources. This analysis modeled the impact of cryoballoon ablation on electrophysiology lab operation using data from Latin America. Methods Data from centers in Argentina, Mexico, Colombia, and Chile of the were used as inputs for an electrophysiology lab efficiency simulation model. The model used the assumption that either two (today’s electrophysiology lab operations) or three (including electrophysiology lab operational changes) cryoballoon ablation procedures could be performed per day. The endpoints were the percentage of days that resulted in 1) overtime and 2) time left for an extra non-ablation electrophysiology procedure. Results Data from a total of 232 procedures from six Latin American centers were included in the analysis. The average electrophysiology lab occupancy time for all procedures in Latin America was 132 ± 62 minutes. In the Current Scenario (two procedures per day), 7.4% of simulated days resulted in overtime, and 81.4% had enough time for an extra electrophysiology procedure. In the Enhanced Productivity Scenario (three procedures per day), 16.4% of days used overtime, while 67.4% allowed time for an extra non-ablation electrophysiology procedure. Conclusions Using real-world, Latin American-specific data, we found that with operational changes, three ablation procedures could feasibly be performed daily, leaving time for an extra electrophysiology procedure on more than half of days. Thus, use of cryoballoon ablation is an effective tool to enhance electrophysiology lab efficiency in resource-constrained regions such as Latin America.