Chee Yin Lam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chee Yin Lam has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Igor A. Chaves
Critical Infrastructure Performance and Reliability Group, The University of Newcastle, Newcastle, Australia
3 shared publications - Mark John Masia
Univ. of Newcastle
3 shared publications Akhtar Hossain
The University of Newcastle, University Dr
1 shared publication- Akhtar Hossain
The University of Newcastle
1 shared publication I. A. Chaves
The University of Newcastle
1 shared publicationIgor Chaves
The University of Newcastle, University Dr
1 shared publication
Latest Publications
- Open Access
- 2 January 2026
- Published by Elsevier in Engineering Structures
- Vol. 351
Experimental and probabilistic analysis of masonry cavity wall ties under out-of-plane loading with application of stochastic numerical analyses
- 2 January 2026
- Published by Elsevier in Engineering Structures
- Vol. 351
Open AccessExperimental and probabilistic analysis of masonry cavity wall ties under out-of-plane loading with application of stochastic numerical analyses
- Open Access
- 25 September 2025
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 27 (1) , 59-69
The impact of corrosion on the behaviour and strength of wall ties in cavity brick walls
- 25 September 2025
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 27 (1) , 59-69
Open AccessThe impact of corrosion on the behaviour and strength of wall ties in cavity brick walls
- Open Access
- 19 September 2025
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 27 (1) , 70-81
Condition assessment of wall ties in masonry cavity wall using vibration-based methods
- 19 September 2025
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 27 (1) , 70-81
Open AccessCondition assessment of wall ties in masonry cavity wall using vibration-based methods
- Open Access
Assessing Wall Tie Deterioration in Masonry Veneer Wall Through Vibration-Based Damage Identification Methods
Experimental modal analysis has proven effective in damage identification of civil structures but has not been extensively applied to multi-leaf masonry structures, particularly in the context of wall tie inspection. This paper investigates the applicability of non-destructive, vibration-based damage identification methods to a one-storey masonry veneer wall to detect wall tie deterioration based on changes in modal parameters. An impact hammer was used to collect vibration data from eight different wall tie deterioration test cases by disconnecting the wall ties at various locations. The downshift of natural frequencies was recorded for all deterioration test cases, and a reduction of up to 38% was observed when the top row of wall ties was disconnected, highlighting the importance of wall ties to the overall stiffness of the masonry veneer wall system. In terms of damage localisation accuracy, the parameter-based method performed the best by successfully identifying seven out of eight damaged scenarios without additional noise. The findings show that the detection of wall tie deterioration using non-destructive, vibration-based damage identification methods is viable, providing an alternative wall tie inspection method with significant benefits to infrastructure management, thereby enhancing safety, efficiency, and sustainability in maintaining and preserving masonry veneer walls.
Open AccessAssessing Wall Tie Deterioration in Masonry Veneer Wall Through Vibration-Based Damage Identification Methods
Experimental modal analysis has proven effective in damage identification of civil structures but has not been extensively applied to multi-leaf masonry structures, particularly in the context of wall tie inspection. This paper investigates the applicability of non-destructive, vibration-based damage identification methods to a one-storey masonry veneer wall to detect wall tie deterioration based on changes in modal parameters. An impact hammer was used to collect vibration data from eight different wall tie deterioration test cases by disconnecting the wall ties at various locations. The downshift of natural frequencies was recorded for all deterioration test cases, and a reduction of up to 38% was observed when the top row of wall ties was disconnected, highlighting the importance of wall ties to the overall stiffness of the masonry veneer wall system. In terms of damage localisation accuracy, the parameter-based method performed the best by successfully identifying seven out of eight damaged scenarios without additional noise. The findings show that the detection of wall tie deterioration using non-destructive, vibration-based damage identification methods is viable, providing an alternative wall tie inspection method with significant benefits to infrastructure management, thereby enhancing safety, efficiency, and sustainability in maintaining and preserving masonry veneer walls.
- 3 September 2024
- Published by Springer Nature
- p. 165-174
Application of Non-destructive Testing Techniques for Condition Assessment of Wall Ties in Masonry Construction
- 3 September 2024
- Published by Springer Nature
- p. 165-174
Application of Non-destructive Testing Techniques for Condition Assessment of Wall Ties in Masonry Construction