Patrick A. Coughlin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Patrick A. Coughlin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Frederick Scarsbrook
Department of Radiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK
2 shared publications - Marc Aaron Bailey
Leeds Institute of Cardiovascular & Metabolic Medicine, School Of Medicine, University Of Leeds, Leeds, United Kingdom
2 shared publications - Russell Frood
Leeds Institute of Clinical Trials Research, University of Leeds , Woodhouse Lane, Leeds
2 shared publications - Alejandro F. Frangi
Centre for Computational Imaging and Modelling in Medicine (CIMIM), The Christabel Pankhurst Institute, The University of Manchester, Oxford Road, Manchester M13 9PL
1 shared publication - Arshpreet Singh Badesha
Department of Radiology, St. James’s University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds LS9 7TF, UK
1 shared publication D. Julian A. Scott
The Leeds Vascular Institute, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Leeds, UK
1 shared publication
Latest Publications
- Open Access
- 5 February 2025
- Published by MDPI AG in Algorithms
- Vol. 18 (2) , 86
Development and External Validation of [18F]FDG PET-CT-Derived Radiomic Models for Prediction of Abdominal Aortic Aneurysm Growth Rate
Objective (1): To develop and validate a machine learning (ML) model using radiomic features (RFs) extracted from [18F]FDG PET-CT to predict abdominal aortic aneurysm (AAA) growth rate. Methods (2): This retrospective study included 98 internal and 55 external AAA patients undergoing [18F]FDG PET-CT. RFs were extracted from manual segmentations of AAAs using PyRadiomics. Recursive feature elimination (RFE) reduced features for model optimisation. A multi-layer perceptron (MLP) was developed for AAA growth prediction and compared against Random Forest (RF), XGBoost, and Support Vector Machine (SVM). Accuracy was evaluated via cross-validation, with uncertainty quantified using dropout (MLP), standard deviation (RF), and 95% prediction intervals (XGBoost). External validation used independent data from two centres. Ground truth growth rates were calculated from serial ultrasound (US) measurements or CT volumes. Results (3): From 93 initial RFs, 29 remained after RFE. The MLP model achieved an MAE ± SEM of 1.35 ± 3.2e−4 mm/year with the full feature set and 1.35 ± 2.5e−4 mm/year with RFE. External validation yielded 1.8 ± 8.9e−8 mm/year. RF, XGBoost, and SVM models produced comparable accuracies internally (1.4–1.5 mm/year) but showed higher errors during external validation (1.9–1.97 mm/year). The MLP model demonstrated reduced uncertainty with the full feature set across all datasets. Conclusions (4): An MLP model leveraging [18F]FDG PET-CT radiomics accurately predicted AAA growth rates and generalised well to external data. In the future, more sophisticated stratification could guide individualised patient care, facilitating risk-tailored management of AAAs.
- 5 February 2025
- Published by MDPI AG in Algorithms
- Vol. 18 (2) , 86
Open AccessDevelopment and External Validation of [18F]FDG PET-CT-Derived Radiomic Models for Prediction of Abdominal Aortic Aneurysm Growth Rate
Objective (1): To develop and validate a machine learning (ML) model using radiomic features (RFs) extracted from [18F]FDG PET-CT to predict abdominal aortic aneurysm (AAA) growth rate. Methods (2): This retrospective study included 98 internal and 55 external AAA patients undergoing [18F]FDG PET-CT. RFs were extracted from manual segmentations of AAAs using PyRadiomics. Recursive feature elimination (RFE) reduced features for model optimisation. A multi-layer perceptron (MLP) was developed for AAA growth prediction and compared against Random Forest (RF), XGBoost, and Support Vector Machine (SVM). Accuracy was evaluated via cross-validation, with uncertainty quantified using dropout (MLP), standard deviation (RF), and 95% prediction intervals (XGBoost). External validation used independent data from two centres. Ground truth growth rates were calculated from serial ultrasound (US) measurements or CT volumes. Results (3): From 93 initial RFs, 29 remained after RFE. The MLP model achieved an MAE ± SEM of 1.35 ± 3.2e−4 mm/year with the full feature set and 1.35 ± 2.5e−4 mm/year with RFE. External validation yielded 1.8 ± 8.9e−8 mm/year. RF, XGBoost, and SVM models produced comparable accuracies internally (1.4–1.5 mm/year) but showed higher errors during external validation (1.9–1.97 mm/year). The MLP model demonstrated reduced uncertainty with the full feature set across all datasets. Conclusions (4): An MLP model leveraging [18F]FDG PET-CT radiomics accurately predicted AAA growth rates and generalised well to external data. In the future, more sophisticated stratification could guide individualised patient care, facilitating risk-tailored management of AAAs.
- 27 January 2025
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 113, 244-253
Benefits of Duplex Ultrasound Surveillance of Infrainguinal Bypass Grafts and Institutional Costs of Graft Failure: A Retrospective Single-Center Study
- 27 January 2025
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 113, 244-253
Benefits of Duplex Ultrasound Surveillance of Infrainguinal Bypass Grafts and Institutional Costs of Graft Failure: A Retrospective Single-Center Study
- Open Access
- 3 September 2024
- Published by MDPI AG in Tomography
- Vol. 10 (9) , 1455-1487
A Scoping Review of Machine-Learning Derived Radiomic Analysis of CT and PET Imaging to Investigate Atherosclerotic Cardiovascular Disease
Background: Cardiovascular disease affects the carotid arteries, coronary arteries, aorta and the peripheral arteries. Radiomics involves the extraction of quantitative data from imaging features that are imperceptible to the eye. Radiomics analysis in cardiovascular disease has largely focused on CT and MRI modalities. This scoping review aims to summarise the existing literature on radiomic analysis techniques in cardiovascular disease. Methods: MEDLINE and Embase databases were searched for eligible studies evaluating radiomic techniques in living human subjects derived from CT, MRI or PET imaging investigating atherosclerotic disease. Data on study population, imaging characteristics and radiomics methodology were extracted. Results: Twenty-nine studies consisting of 5753 patients (3752 males) were identified, and 78.7% of patients were from coronary artery studies. Twenty-seven studies employed CT imaging (19 CT carotid angiography and 6 CT coronary angiography (CTCA)), and two studies studied PET/CT. Manual segmentation was most frequently undertaken. Processing techniques included voxel discretisation, voxel resampling and filtration. Various shape, first-order, second-order and higher-order radiomic features were extracted. Logistic regression was most commonly used for machine learning. Conclusion: Most published evidence was feasibility/proof of concept work. There was significant heterogeneity in image acquisition, segmentation techniques, processing and analysis between studies. There is a need for the implementation of standardised imaging acquisition protocols, adherence to published reporting guidelines and economic evaluation.
- 3 September 2024
- Published by MDPI AG in Tomography
- Vol. 10 (9) , 1455-1487
Open AccessA Scoping Review of Machine-Learning Derived Radiomic Analysis of CT and PET Imaging to Investigate Atherosclerotic Cardiovascular Disease
Background: Cardiovascular disease affects the carotid arteries, coronary arteries, aorta and the peripheral arteries. Radiomics involves the extraction of quantitative data from imaging features that are imperceptible to the eye. Radiomics analysis in cardiovascular disease has largely focused on CT and MRI modalities. This scoping review aims to summarise the existing literature on radiomic analysis techniques in cardiovascular disease. Methods: MEDLINE and Embase databases were searched for eligible studies evaluating radiomic techniques in living human subjects derived from CT, MRI or PET imaging investigating atherosclerotic disease. Data on study population, imaging characteristics and radiomics methodology were extracted. Results: Twenty-nine studies consisting of 5753 patients (3752 males) were identified, and 78.7% of patients were from coronary artery studies. Twenty-seven studies employed CT imaging (19 CT carotid angiography and 6 CT coronary angiography (CTCA)), and two studies studied PET/CT. Manual segmentation was most frequently undertaken. Processing techniques included voxel discretisation, voxel resampling and filtration. Various shape, first-order, second-order and higher-order radiomic features were extracted. Logistic regression was most commonly used for machine learning. Conclusion: Most published evidence was feasibility/proof of concept work. There was significant heterogeneity in image acquisition, segmentation techniques, processing and analysis between studies. There is a need for the implementation of standardised imaging acquisition protocols, adherence to published reporting guidelines and economic evaluation.