FFFabrizio Fasano

Fabrizio Fasano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabrizio Fasano has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Human brain cortical oxygen consumption is positively related to soma surface area density

    by Manuela Carriero, Alessandra Caporale, Davide Di Censo, Ian Driver, Elizabeth J. Fear, Hannah Chandler, Fabrizio Fasano, Domenico Zacà, Emma Biondetti, Carolyn McNabb, et al.

    Evidence from in-silico, ex vivo and invasive animal studies suggested the function of neural tissue to be inextricably linked to its structural and microstructural organization. However, this link has never been assessed non-invasively in humans. Here, we established a simple quantitative framework linking cerebral oxygen metabolism to gray matter microstructural features in healthy humans using advanced non-invasive MRI methods. The cerebral metabolic rate of oxygen consumption (CMRO₂) was quantified with calibrated fMRI, whereas microstructural properties were estimated from diffusion MRI data fitted to the Soma and Neurite Density Imaging (SANDI) model, yielding soma radius ( R soma ) and soma volume fraction ( f soma ) metrics, from which we derived maps of soma surface area density (SAD) and soma numerical density (ND) under the assumption of a spherical soma. CMRO₂ was positively associated with SAD (r = 0.29, p < 0.01), f soma (r = 0.28, p < 0.05) and ND (r = 0.25, p < 0.05), and negatively associated with R soma (r = −0.23, p < 0.05) across cortical brain regions. These relationships are consistent with predictions from experimental and theoretical studies, providing the first quantitative evidence that cerebral metabolic demand is coupled to microstructure in humans. The positive association of energy consumption with SAD is consistent with the notion that both the number of synapses (energy-demanding structures), and the energy required to maintain a membrane potential, scale with soma surface area. Our findings establish a non-invasive MRI framework for investigating the microstructural determinants of brain energy metabolism in health and potentially in disease.

  • Open Access

    Open-Source Framework for Measurement of the Gradient Impulse Response Function

    by James B. Bacon, Rudy Rizzo, Simon M. Finney, C. John Evans, Fabrizio Fasano, Peter Jezzard, William T. Clarke

    The Gradient Impulse Response Function (GIRF) is widely used to model and correct gradient system imperfections in MRI, but scanner-specific GIRF measurement remains inaccessible to many research groups because existing approaches rely on specialised field monitoring hardware or fragmented and non-reproducible software workflows. To address this limitation, an open-source, end-to-end framework for phantom-based GIRF measurement is presented, providing a reproducible workflow requiring only standard MRI hardware and a spherical water phantom. The framework integrates vendor-independent pulse sequence generation, phantom-based data acquisition, automated data processing, and GIRF estimation. The framework was validated by comparing GIRF-predicted non-Cartesian k-space trajectories with independent measurements acquired using NMR field probes, which served as the gold-standard for trajectory characterization. Accurate prediction of rosette and spiral trajectories was demonstrated across multiple imaging orientations, with substantially lower trajectory error than the corresponding nominal trajectories. By providing the first openly available end-to-end implementation for phantom-based GIRF measurement, the barrier to routine scanner-specific GIRF characterisation is reduced, facilitating broader adoption of GIRF-based methods across the MRI community.

  • Open Access

    Giving the prostate the boost it needs: Spiral diffusion MRI using a high‐performance whole‐body gradient system for high b‐values at short echo times

    by Malwina Molendowska, Lars Mueller, Fabrizio Fasano, Derek K. Jones, Chantal M. W. Tax, Maria Engel

    Purpose: To address key issues of low SNR and image distortions in prostate diffusion MRI (dMRI) by means of using strong gradients, single‐shot spiral readouts and an expanded encoding model for image reconstruction.Methods: Diffusion‐weighted spin echo imaging with EPI and spiral readouts is performed on a whole‐body system equipped with strong gradients (up to 250 mT/m). An expanded encoding model including static off‐resonance, coil sensitivities, and magnetic field dynamics is employed for image reconstruction. The acquisitions are performed on a phantom and in vivo (one healthy volunteer and one patient with prostate cancer). The resulting images are compared to conventional dMRI EPI with navigator‐based image reconstruction and assessed in terms of their congruence, SNR, tissue contrast, and quantitative parameters.Results: Using the expanded encoding model, high‐quality images of the prostate gland are obtained across all b‐values (up to 3 ms/μm2), clearly outperforming the results obtained with conventional image reconstruction. Compared to EPI, spiral imaging provides an SNR gain up to 45% within the gland and even higher in the lesion. In addition, prostate dMRI with single‐shot spirals at submillimeter in‐plane resolution (0.85 mm) is accomplished.Conclusion: The combination of strong gradients and an expanded encoding model enables imaging of the prostate with unprecedented image quality. Replacing the commonly used EPI with spirals provides the inherent benefit of shorter echo times and superior readout efficiency and results in higher SNR, which is in particular relevant for considered applications.


  • Open Access

    Diffusion MRI in prostate cancer with ultra‐strong whole‐body gradients

    by Malwina Molendowska, Marco Palombo, Kieran G. Foley, Krishna Narahari, Fabrizio Fasano, Derek K. Jones, Daniel C. Alexander, Eleftheria Panagiotaki, Chantal M. W. Tax

    Diffusion‐weighted MRI (dMRI) is universally recommended for the detection and classification of prostate cancer (PCa), with PI‐RADS recommendations to acquire b‐values of ≥1.4 ms/μm2. However, clinical dMRI suffers from a low signal‐to‐noise ratio (SNR) as the consequence of prolonged echo times (TEs) attributable to the limited gradient power in the range of 40–80 mT/m. To overcome this, MRI systems with strong gradients have been designed but so far have mainly been applied in the brain. The aim of this work was to assess the feasibility, data quality, SNR and contrast‐to‐noise ratio (CNR) of measurements in PCa with a 300 mT/m whole‐body system. A cohort of men without and with diagnosed PCa were imaged on a research‐only 3T Connectom Siemens MRI system equipped with a gradient amplitude of 300 mT/m. dMRI at high b‐values were acquired using high gradient amplitudes and compared with gradient capabilities mimicking clinical systems. Data artefacts typically amplified with stronger gradients were assessed and their correction evaluated. The SNR gains and lesion‐to‐healthy tissue CNR were statistically tested investigating the effect of protocol and b‐value. The diagnostic quality of the images for different dMRI protocols was assessed by an experienced radiologist using a 5‐point Likert scale and an adapted PI‐QUAL scoring system. The strong gradients for prostate dMRI allowed a significant gain in SNR per unit time compared with clinical gradients. Furthermore, a 1.6–2.1‐fold increase in CNR was observed. Despite the more pronounced artefacts typically associated with strong gradients, a satisfactory correction could be achieved. Smoother and less biased parameter maps were obtained with protocols at shorter TEs. The results of this study show that dMRI in PCa with a whole‐body 300‐mT/m scanner is feasible without a report of physiological effects, SNR and CNR can be improved compared with lower gradient strengths, and artefacts do not negate the benefits of strong gradients and can be ameliorated. This assessment provides the first essential step towards unveiling the full potential of cutting‐edge scanners, now increasingly becoming available, to advance early detection and diagnostic precision.