Casper F Zijderhand
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Casper F Zijderhand has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Ad J. J. C. Bogers
Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands
1 shared publication - Bart Meyns
Department of Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
1 shared publication - Béla Merkely
Heart and Vascular Centre, Semmelweis University, Budapest, Hungary
1 shared publication - Christiaan F J Antonides
Department of Cardio-Thoracic Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
1 shared publication - Felix Schoenrath
Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC) , Berlin
1 shared publication - Francesco Musumeci
Politecnico di Milano
1 shared publication
Latest Publications
- Open Access
- 1 August 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (3)
Shared care for patients with a left ventricular assist device: a scoping review
Left ventricular assist devices (LVADs) are increasingly implanted in patients with advanced heart failure. Currently, LVAD care is predominantly concentrated at specialized tertiary care hospitals. However, the increasing workload and logistical burden for implanting centres pose significant challenges to accessing care for individual patients in remote areas. An emerging approach to LVAD patient management is the use of a shared care model (SCM), which facilitates collaboration between implanting centres and local non-implanting hospitals. This scoping review explores and synthesizes the current scientific evidence on the use of SCMs in LVAD care management. Eligible studies were identified in EMBASE, PubMed MEDLINE, Web of Science, Cochrane and Google Scholar. Findings were synthesized in accordance with PRISMA-ScR guidelines. Of the 950 records screened, five articles met the inclusion criteria. Four review articles focused on the proposed benefits and challenges of using SCMs. Main benefits included improved patient satisfaction and continuity of care. Important challenges were initial education of non-implanting centre staff and maintaining competency. One prospective study showed that absence of LVAD-specific care was associated with impaired survival and higher rates of pump thrombosis and LVAD-related infections. The use of SCMs is a promising approach in the long-term management of LVAD patients. However, sufficient evidence about the impact of SCMs on patients and the healthcare system is not currently available. Standardized protocols based on prospective studies are needed to develop safe and effective shared care for LVAD patients.
- 1 August 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (3)
Open AccessShared care for patients with a left ventricular assist device: a scoping review
Left ventricular assist devices (LVADs) are increasingly implanted in patients with advanced heart failure. Currently, LVAD care is predominantly concentrated at specialized tertiary care hospitals. However, the increasing workload and logistical burden for implanting centres pose significant challenges to accessing care for individual patients in remote areas. An emerging approach to LVAD patient management is the use of a shared care model (SCM), which facilitates collaboration between implanting centres and local non-implanting hospitals. This scoping review explores and synthesizes the current scientific evidence on the use of SCMs in LVAD care management. Eligible studies were identified in EMBASE, PubMed MEDLINE, Web of Science, Cochrane and Google Scholar. Findings were synthesized in accordance with PRISMA-ScR guidelines. Of the 950 records screened, five articles met the inclusion criteria. Four review articles focused on the proposed benefits and challenges of using SCMs. Main benefits included improved patient satisfaction and continuity of care. Important challenges were initial education of non-implanting centre staff and maintaining competency. One prospective study showed that absence of LVAD-specific care was associated with impaired survival and higher rates of pump thrombosis and LVAD-related infections. The use of SCMs is a promising approach in the long-term management of LVAD patients. However, sufficient evidence about the impact of SCMs on patients and the healthcare system is not currently available. Standardized protocols based on prospective studies are needed to develop safe and effective shared care for LVAD patients.
- Open Access
- 1 October 2021
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 42 (Supplement)
VAD related infections and the risk of pump thrombosis and thromboembolic events: a EUROMACS study
Background: In patients supported by a ventricular assist device (VAD) major infections are a frequently reported adverse event with increased morbidity and mortality. Purpose: The purpose of this study was to investigate the possible association between infections and cerebrovascular accidents (CVAs) in VAD patients. Methods: An analysis of the European Registry for Patients Assisted with Mechanical Circulatory Support (EUROMACS) was performed identifying all patients aged ≥18 years with a LVAD or BiVAD implantation. Infections were categorized as VAD-specific infections, VAD-related infections and, non-VAD infections. An extended Kaplan-Meier analysis for the risk of CVA and mortality with infection as a time-dependent covariate was performed. Furthermore, a multivariable Cox proportional hazard model was performed including 24 variables. Results: For this analysis 3784 patients were included, with 45 patients being supported by a BiVAD and 3739 by an LVAD. The majority of patients were male (83.2%) and 60.5% had an INTERMACS patient profile 2 or 3. During follow-up, 3108 major infections were identified in 1385 (36.6%) of the patients, while 673 CVAs were identified in 545 (14.4%) of the patients. Extended Kaplan-Meier analysis with first infection as time-dependent covariate revealed a hazard ratio (HR) for CVA of 1.95 (95% CI: 1.57–2.36; p<0.005) (Figure) and 1.50 (95% CI: 1.33–1.68, p<0.005) for mortality. Multivariable analysis confirmed a significant association for infection and CVAs with a HR of 1.46 (95% CI: 1.29–1.64). With infections subcategorized, VAD-specific (HR: 1.57 (95% CI: 1.18–2.09)) and VAD-related infections (HR: 2.04 (95% CI: 1.44–2.89)) remained significantly associated with CVA but non-VAD infections (HR: 1.22 (95% CI: 0.92–1.64)) were not. Conclusion: Both VAD-related and VAD-specific infections are associated with a significantly increased risk of CVA with increased risk of mortality. Funding Acknowledgement: Type of funding sources: None. KM freedom of CVA and infection
- 1 October 2021
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 42 (Supplement)
Open AccessVAD related infections and the risk of pump thrombosis and thromboembolic events: a EUROMACS study
Background: In patients supported by a ventricular assist device (VAD) major infections are a frequently reported adverse event with increased morbidity and mortality. Purpose: The purpose of this study was to investigate the possible association between infections and cerebrovascular accidents (CVAs) in VAD patients. Methods: An analysis of the European Registry for Patients Assisted with Mechanical Circulatory Support (EUROMACS) was performed identifying all patients aged ≥18 years with a LVAD or BiVAD implantation. Infections were categorized as VAD-specific infections, VAD-related infections and, non-VAD infections. An extended Kaplan-Meier analysis for the risk of CVA and mortality with infection as a time-dependent covariate was performed. Furthermore, a multivariable Cox proportional hazard model was performed including 24 variables. Results: For this analysis 3784 patients were included, with 45 patients being supported by a BiVAD and 3739 by an LVAD. The majority of patients were male (83.2%) and 60.5% had an INTERMACS patient profile 2 or 3. During follow-up, 3108 major infections were identified in 1385 (36.6%) of the patients, while 673 CVAs were identified in 545 (14.4%) of the patients. Extended Kaplan-Meier analysis with first infection as time-dependent covariate revealed a hazard ratio (HR) for CVA of 1.95 (95% CI: 1.57–2.36; p<0.005) (Figure) and 1.50 (95% CI: 1.33–1.68, p<0.005) for mortality. Multivariable analysis confirmed a significant association for infection and CVAs with a HR of 1.46 (95% CI: 1.29–1.64). With infections subcategorized, VAD-specific (HR: 1.57 (95% CI: 1.18–2.09)) and VAD-related infections (HR: 2.04 (95% CI: 1.44–2.89)) remained significantly associated with CVA but non-VAD infections (HR: 1.22 (95% CI: 0.92–1.64)) were not. Conclusion: Both VAD-related and VAD-specific infections are associated with a significantly increased risk of CVA with increased risk of mortality. Funding Acknowledgement: Type of funding sources: None. KM freedom of CVA and infection