DMDahyr Olivas Medina

Dahyr Olivas Medina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dahyr Olivas Medina has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Andrés Íñiguez-Romo

    Cardiology Department, Complexo Hospitalario Universitario de Vigo (SERGAS), Álvaro Cunqueiro Hospital, 36213 Vigo, Spain

    2 shared publications
  • Pablo Juan-Salvadores

    University Hospital of Vigo, Espanha; Galicia Sur Health Research Institute, Espanha

    2 shared publications
  • Victor Alfonso Jimenez Diaz

    Department of Cardiology, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain

    2 shared publications
  • Alfonso Reyes Mitre

    Hemodynamic & Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Estrada Clara Campoamor 341, 36312 Vigo, Spain

    1 shared publication
  • Andrés Iñiguez Romo

    Grupo de Pesquisa Cardiovascular, Instituto de Investigación Sanitaria Galicia Sur (IIS Galicia Sur). SERGAS-UVIGO, Spain; Departamento de Cardiologia, Hospital Álvaro Cunqueiro, Área Sanitária de Vigo, Spain; Consórcio de Investigação Biomédica em Cardiologia (CIBERCV), Vigo, Espanha

    1 shared publication
  • C Veiga-Garcia

    University Hospital Alvaro Cunqueiro , Vigo , Spain

    1 shared publication

Latest Publications

  • Open Access

    Minimizing Permanent Pacemaker Implantation After TAVR: Current Strategies, Monitoring Pathways, and Future Directions

    by Alfonso Reyes Mitre, Hector Lopez de la Garza, Claudio Espada Guerreiro, Dahyr Olivas Medina, Erick Marlon Avila Gil, Pablo Juan Salvadores, José Antonio Baz Alonso, Andres Iñiguez Romo, Victor Alfonso Jimenez Diaz

    Transcatheter aortic valve replacement (TAVR) has evolved over the last two decades into a cornerstone therapy for patients with severe symptomatic aortic stenosis. This therapy was initially reserved for those at high or prohibitive surgical risk but is now firmly established across all surgical risk categories. Its non-inferiority to surgical aortic valve replacement has been demonstrated even in low-risk populations, supporting the rapid worldwide expansion of its use. Nevertheless, despite procedural refinements and the advent of newer-generation prostheses, conduction disturbances leading to permanent pacemaker implantation (PPI) remain one of the most frequent and clinically relevant complications. Reported incidence ranges between 8% and 20% depending on prosthesis type, implantation technique, and baseline patient characteristics. Multiple clinical, anatomical, and procedural factors have been identified as strong predictors of post-TAVR conduction disturbances. Taken together, the integration of anatomical and clinical risk assessment, precise procedural planning, careful device selection, structured monitoring, and emerging therapeutic strategies constitutes a comprehensive, evidence-based approach to reduce the burden of conduction disturbances following TAVR. Such a multimodal framework has the potential not only to lower the incidence of permanent pacemaker implantation but also to improve safety, optimize healthcare resource utilization, and support the broader adoption of TAVR in increasingly younger and lower-risk patient populations.


  • Open Access

    Clinical features and long-term outcomes in patients under 35 years with coronary artery disease: Nested case–control study

    by Pablo Juan-Salvadores, Dahyr Olivas-Medina, Luis Mariano de la Torre Fonseca, Cesar Veiga, Silvia Campanioni, Francisco Caamaño Isorna, Andrés Iñiguez Romo, Víctor Alfonso Jiménez Díaz


  • Open Access

    Value of basal HV Interval prior TAVR as predictor of permanent pacemaker implantation

    by D Olivas Medina, P Juan-Salvadores, E Teijeira-Fernandez, M P Cabanas-Grandio, M Pardo-Fresno, E Fernadez-Obanza, A Salgado-Barreira, H Lopez-De La Garza, C Veiga-Garcia, J A Baz-Alonso, et al.

    Background/Introduction: Transfemoral aortic valve replacement (TAVR) is an effective and safe treatment for severe aortic stenosis (SAoS) even in low risk patients (1,2). As population ages, the volume of TAVR procedure increases and although improvements in technology and technique, new onset persistent disturbances in the electrocardiogram (ECG) are present up to 34,8% of patients at hospital discharge(3) and the secondary need of permanent pacemaker implantation (PPM) remains high, being of 4-24% with balloon-expanding valves (BEV) and 14.7-26.7% with self-expanding valves (SEV)(3). According to ESC guidelines, an electrophyisiologic study (EPS) centered in HV interval measure with a cutoff of ≥70ms is a useful tool to assess the risk of progression to high auriculoventricular block (HAVB) in specific groups with persistent ECG abnormalities to consider PPM(4-5), but this only applies in post TAVR scenario. Measuring HV interval at the intervention day prior procedure could help optimize and assess risk for PPM post TAVR. Purpose: To measure basal HV interval prior TAVR and correlate it to risk of PPM implantation before discharge and 30 days after discharge. Methods: Single-center prospective cohort study, patients with SAoS scheduled for TAVR, sinus rhythm at intervention day, without PPM or history of PPM indication were included. At time of TAVR, a tetrapolar catheter was placed at the septal aspect of tricuspid valve. A mobile polygraph was used to measure ECG parameters and HV interval before TAVR. Then, tetrapolar catheter was advanced to ventricle to perform rapid stimulation as part of habitual valve implantation protocol. After procedure, a rhythm monitorization for >48-72 hrs, was made to decide, PPM, HV interval measure or clinical daily ECG vigilance with posterior discharge was performed. A 30-day post discharge follow up was expected. Results: 38 patients were enrolled, median age 83.5 ± 5.5 years, 23 females (60,5%). 37 patients had SEV implanted and 1 patient had BEV implanted. Median HV interval was 54.4ms. 18 patients (47.4%) had a mild abnormal HV interval, of whom 11 had a narrow QRS. Post TAVR procedure, 15 patients (39.5%) persisted with "de novo" LBB at discharge. 5 women and 7 men, had PPM implanted before discharge. 1 woman was implanted 6 days after discharge due to HAVB (66ms HV interval prior TAVR). In a multivariate analysis including sex, age, PR, QRS and HV interval >55ms, the RR (IC 95% 1.9-70.3) risk of PPM was 13.42 folds higher (p=0.008). At a bivariate quantitative HV analysis, a higher HV period persisted significantly related to PPM outcome (p=0.001). Conclusions: In our study population, a pre-existing mild to moderate prolongation of HV interval prior TAVR substantially elevates the risk of requiring PPM before discharge. 61.1% of these basal mild prolongation HV interval patients had a narrow QRS prior TAVR.HV measure prior TAVR in narrow QRSTable 1