Ming Hao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ming Hao has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Lihai Zhang
China Department of Orthopedics, Chinese PLA General Hospital, Beijing 100141, China
2 shared publications - Peifu Tang
Senior Department of Orthopedics The Fourth Medical Center of Chinese PLA General Hospital Beijing China
2 shared publications Gang Zhang
National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
1 shared publication- Houchen Lyu
Department of Orthopedics Chinese PLA General Hospital Beijing China
1 shared publication - Hua Chen
Senior Department of Orthopedics, The Fourth Medical Center of PLA general hospital, Beijing, China
1 shared publication Hui Guo
Department of Orthopedics, the First Medical Center, Chinese PLA General Hospital, Beijing, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 12 November 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
Biomechanical study of a novel external fixation frame controlling postoperative loss of reduction in thoracolumbar fractures: Finite element analysis
Objective: This study aims to investigate the biomechanical characteristics of percutaneous pedicle screw fixation combined with a novel external fixation device (Micro-Adjustable External Fixation - MAEF) for minimally invasive spinal fracture treatment using finite element analysis, providing theoretical support for clinical application. Methods: We simulated an L1 vertebral fracture and constructed two finite element models: CASE 1: Micro-Adjustable External Fixation (MAEF), CASE 2: Percutaneous Short-Segment Intermediate Screw Fixation (PSISF). Under load control, we recorded the percentage change in ROM values before and after fixation for both models, along with maximum stress values at the fixation system, fractured vertebra (L1), T12 inferior endplate, and L2 superior endplate. Results: Under all loading conditions, the ROM of the MAEF model was normalized to the ROM of the intact T11–L3 model, ranging from 8.4% to 15.5%. The ROM of the PSISF model was normalized to the intact T12–L2 model, ranging from 48.0% to 70.9%. Compared with the PSISF model, the MAEF model exhibited lower maximum stress values in the fixation system, fractured vertebra (L1), inferior endplate of T12, and superior endplate of L2. Furthermore, the maximum stress values for the fixation systems in both models occurred under lateral rotation conditions: the MAEF model’s fixation system peaked at 77.025 MPa during right rotation, while the PSISF model’s fixation system peaked at 170.97 MPa during left rotation. Significantly, contrary to the PSISF model results, the fractured vertebral body (L1) in the MAEF model exhibited markedly higher maximum stress values during flexion and extension compared to lateral bending, left rotation, and right rotation. These values were comparable to the maximum stresses observed in the PSISF model during flexion and extension, a phenomenon attributed to the MAEF model’s micro-adjustable system. Additionally, under all loading conditions, the maximum stress values at the adjacent vertebral endplates in the MAEF model were lower than those in the PSISF model. Conclusion: Theoretically, these biomechanical features of MAEF may lower the risk of implant failure and post-traumatic kyphosis and facilitate fracture healing, supporting its potential for minimally invasive treatment of thoracolumbar burst fractures.
- 12 November 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
Open AccessBiomechanical study of a novel external fixation frame controlling postoperative loss of reduction in thoracolumbar fractures: Finite element analysis
Objective: This study aims to investigate the biomechanical characteristics of percutaneous pedicle screw fixation combined with a novel external fixation device (Micro-Adjustable External Fixation - MAEF) for minimally invasive spinal fracture treatment using finite element analysis, providing theoretical support for clinical application. Methods: We simulated an L1 vertebral fracture and constructed two finite element models: CASE 1: Micro-Adjustable External Fixation (MAEF), CASE 2: Percutaneous Short-Segment Intermediate Screw Fixation (PSISF). Under load control, we recorded the percentage change in ROM values before and after fixation for both models, along with maximum stress values at the fixation system, fractured vertebra (L1), T12 inferior endplate, and L2 superior endplate. Results: Under all loading conditions, the ROM of the MAEF model was normalized to the ROM of the intact T11–L3 model, ranging from 8.4% to 15.5%. The ROM of the PSISF model was normalized to the intact T12–L2 model, ranging from 48.0% to 70.9%. Compared with the PSISF model, the MAEF model exhibited lower maximum stress values in the fixation system, fractured vertebra (L1), inferior endplate of T12, and superior endplate of L2. Furthermore, the maximum stress values for the fixation systems in both models occurred under lateral rotation conditions: the MAEF model’s fixation system peaked at 77.025 MPa during right rotation, while the PSISF model’s fixation system peaked at 170.97 MPa during left rotation. Significantly, contrary to the PSISF model results, the fractured vertebral body (L1) in the MAEF model exhibited markedly higher maximum stress values during flexion and extension compared to lateral bending, left rotation, and right rotation. These values were comparable to the maximum stresses observed in the PSISF model during flexion and extension, a phenomenon attributed to the MAEF model’s micro-adjustable system. Additionally, under all loading conditions, the maximum stress values at the adjacent vertebral endplates in the MAEF model were lower than those in the PSISF model. Conclusion: Theoretically, these biomechanical features of MAEF may lower the risk of implant failure and post-traumatic kyphosis and facilitate fracture healing, supporting its potential for minimally invasive treatment of thoracolumbar burst fractures.
- Open Access
- 21 October 2026
- Published by Springer Nature in Scientific Data
A CT-based 3D pelvic anatomy dataset of 99 healthy Chinese subjects for anatomical landmark detection
- 21 October 2026
- Published by Springer Nature in Scientific Data
Open AccessA CT-based 3D pelvic anatomy dataset of 99 healthy Chinese subjects for anatomical landmark detection
- 15 February 2025
- Vol. 39 (2) , 129-133
智能骨科机器人辅助股骨髓内钉远端锁定实验研究
探讨自主研发的智能骨科机器人辅助股骨髓内钉远端锁定的优势与效果。 将32个成人尸体股骨标本随机分为两组,每组 16 个。实验组采用智能骨科机器人辅助股骨髓内钉远端锁孔锁定,对照组采用传统X线透视下手工锁定方法。记录并比较两组锁定时间、透视次数及首次锁定成功率。 实验组锁定时间为(273.94±38.67)s,明显短于对照组的(378.38±152.72)s;透视次数为(4.56±0.81)次,明显少于对照组的(8.00±3.98)次;差异均有统计学意义 [MD=73.054(−37.187,85.813),P=0.049;MD=1.969(−1.437,2.563),P=0.002]。实验组首次锁定成功率为100%(16/16),明显高于对照组68.75%(11/16),差异有统计学意义(P=0.043)。 与传统透视下手工锁定相比,智能骨科机器人辅助股骨髓内钉远端锁定可以明显减少锁定时间及术中辐射,提高锁定成功率。
- 15 February 2025
- Vol. 39 (2) , 129-133
智能骨科机器人辅助股骨髓内钉远端锁定实验研究
探讨自主研发的智能骨科机器人辅助股骨髓内钉远端锁定的优势与效果。 将32个成人尸体股骨标本随机分为两组,每组 16 个。实验组采用智能骨科机器人辅助股骨髓内钉远端锁孔锁定,对照组采用传统X线透视下手工锁定方法。记录并比较两组锁定时间、透视次数及首次锁定成功率。 实验组锁定时间为(273.94±38.67)s,明显短于对照组的(378.38±152.72)s;透视次数为(4.56±0.81)次,明显少于对照组的(8.00±3.98)次;差异均有统计学意义 [MD=73.054(−37.187,85.813),P=0.049;MD=1.969(−1.437,2.563),P=0.002]。实验组首次锁定成功率为100%(16/16),明显高于对照组68.75%(11/16),差异有统计学意义(P=0.043)。 与传统透视下手工锁定相比,智能骨科机器人辅助股骨髓内钉远端锁定可以明显减少锁定时间及术中辐射,提高锁定成功率。
- Open Access
- 25 November 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 183
Femoral nonunion with segmental bone defect treated by distraction osteogenesis with monolateral external fixation
Currently, the common treatment for femoral nonunion with large segmental bone defect is difficult and complex. The effective surgical methods are rare, include vascularized bone grafting, Masquelet technique and Ilizarov distraction osteogenesis. The objective of this study is to investigate the outcomes of segmental femoral defects treated with monolateral external fixation using the distraction osteogenesis. We retrospectively analyzed patients with femoral nonunion with segmental bone defects (> 6 cm) between January 2010 and January 2014 in our single trauma center. All patients were treated by distraction osteogenesis with monolateral external fixation. All surgeries were performed by the same surgeon. Bone union, duration of distraction osteogenesis in days, time to consolidation in months, external fixation index (EFI), complications, and additional surgical interventions were recorded postoperatively. The modified Application of Methods of Illizarov (ASAMI) criteria were used to evaluate the operative effectiveness. Forty-one patients were enrolled in this study for analysis. The length of the bone defect ranged from 6 to 17 cm. All patients eventually achieved healing, and no patient experienced recurrence of infection or newly developed infection. The average time needed for healing was 13 months. In terms of the incidence of complications, 3 cases axial deviations, 5 cases docking site nonunion, 23 cases pin-tract infection, 14 cases knee joint stiffness or their joint mobility declined, 2 cases osteogenesis insufficient in the distraction area,1 case refracture, and 2 cases loose external fixation pins. In terms of the evaluations of fracture healing and function, 30 patients excellent, 6 patients good, 5 patients fair, and 0 patient poor. In terms of postoperative function evaluations, 21 patients excellent, 9 patients good, 7 patients fair, and 4 patients poor. For patients with femoral nonunion with large segmental bone defects, the monolateral external fixation can provide effective stability, improve compliance, and reduce complications.
- 25 November 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 183
Open AccessFemoral nonunion with segmental bone defect treated by distraction osteogenesis with monolateral external fixation
Currently, the common treatment for femoral nonunion with large segmental bone defect is difficult and complex. The effective surgical methods are rare, include vascularized bone grafting, Masquelet technique and Ilizarov distraction osteogenesis. The objective of this study is to investigate the outcomes of segmental femoral defects treated with monolateral external fixation using the distraction osteogenesis. We retrospectively analyzed patients with femoral nonunion with segmental bone defects (> 6 cm) between January 2010 and January 2014 in our single trauma center. All patients were treated by distraction osteogenesis with monolateral external fixation. All surgeries were performed by the same surgeon. Bone union, duration of distraction osteogenesis in days, time to consolidation in months, external fixation index (EFI), complications, and additional surgical interventions were recorded postoperatively. The modified Application of Methods of Illizarov (ASAMI) criteria were used to evaluate the operative effectiveness. Forty-one patients were enrolled in this study for analysis. The length of the bone defect ranged from 6 to 17 cm. All patients eventually achieved healing, and no patient experienced recurrence of infection or newly developed infection. The average time needed for healing was 13 months. In terms of the incidence of complications, 3 cases axial deviations, 5 cases docking site nonunion, 23 cases pin-tract infection, 14 cases knee joint stiffness or their joint mobility declined, 2 cases osteogenesis insufficient in the distraction area,1 case refracture, and 2 cases loose external fixation pins. In terms of the evaluations of fracture healing and function, 30 patients excellent, 6 patients good, 5 patients fair, and 0 patient poor. In terms of postoperative function evaluations, 21 patients excellent, 9 patients good, 7 patients fair, and 4 patients poor. For patients with femoral nonunion with large segmental bone defects, the monolateral external fixation can provide effective stability, improve compliance, and reduce complications.