CWCanran Wang

Canran Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Canran Wang has a total of 77 co-authors. Here are the top co-authors by number of shared publications:

  • Wei Gao

    Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA

    5 shared publications
  • Hong Han

    Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, USA

    4 shared publications
  • Jihong Min

    Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA

    4 shared publications
  • Wenzheng Heng

    Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA

    4 shared publications
  • Gwangmook Kim

    Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, USA

    3 shared publications
  • Ehsan Shirzaei Sani

    Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA

    2 shared publications

Latest Publications

  • Top Cited Papers
    Open Access

    A bioinspired microfluidic wearable sensor for multiday sweat sampling, transport, and metabolic analysis

    by Soyoung Shin, Ruixiao Liu, Yiran Yang, José A. Lasalde-Ramírez, Gwangmook Kim, Chihyeong Won, Jihong Min, Canran Wang, Kexin Fan, Hong Han, et al.

    Wearable sweat sensors enable noninvasive real-time biochemical monitoring, holding immense potential for personalized health care applications. However, achieving prolonged and reliable sweat sampling, along with stable biochemical analysis, remains challenging due to inconsistent secretion, rapid evaporation, and the reliance on external stimulation. Here, we present BMS 3 , a bioinspired microfluidic wearable sweat sensor system designed for multiday continuous metabolic monitoring. BMS 3 integrates hierarchically graded microchannels and superhydrophobic-superhydrophilic Janus membranes, inspired by pitcher plant trichomes and lotus leaves to enable efficient low volume sweat collection, transport, and renewal. A miniaturized carbachol gel–based iontophoresis module autonomously induces localized sweat secretion. Furthermore, the microfluidic design sustains sweat sampling for over 2 days from a single iontophoresis session, eliminating the need for physical exertion. In vitro and in vivo studies in healthy participants and patients with gout demonstrate BMS 3 ’s capability for continuous metabolic monitoring. By simultaneously tracking uric acid, xanthine, and alcohol levels, it effectively differentiates normal and pathological states while delivering timely therapeutic feedback.


  • Top Cited Papers
    Open Access

    Stressomic: A wearable microfluidic biosensor for dynamic profiling of multiple stress hormones in sweat

    by Jiaobing Tu, Jeonghee Yeom, Joshua Chaj Ulloa, Samuel A. Solomon, Jihong Min, Wenzheng Heng, Gwangmook Kim, Jadelynn Dao, Rohan Vemu, Marion Pang, et al.

    Managing stress is essential for mental and physical health, yet current methods rely on subjective self-assessments or indirect physiological measurements, often lacking accuracy. Existing wearable sensors primarily target a single stress hormone, cortisol, using single-point measurements that fail to capture real-time changes and distinguish between acute and chronic stress. To address this, we present Stressomic, a wearable multiplexed microfluidic biosensor for noninvasive monitoring of cortisol, epinephrine, and norepinephrine in sweat. Stressomic integrates iontophoresis-driven sweat extraction with bursting valve-regulated microfluidic channels for continuous sampling and analysis. Gold nanodendrite–decorated laser-engraved graphene electrodes achieve picomolar-level sensitivity, enabling simultaneous detection of multiple stress hormones. Electrochemical assays and human studies demonstrate that Stressomic reliably tracks hormone fluctuations in response to physical, psychological, and pharmacological stressors. Distinct temporal patterns reveal the dynamic interplay between the hypothalamic-pituitary-adrenal axis and the sympathetic nervous system. This platform enables continuous, multiplexed stress profiling, offering opportunities for early detection of maladaptive responses, personalized stress management, and deeper insights into stress biology.


  • Top Cited Papers

    A microfluidic wearable device for wound exudate management and analysis in human chronic wounds

    by Canran Wang, Kexin Fan, Ehsan Shirzaei Sani, José A. Lasalde-Ramírez, Wenzheng Heng, Jihong Min, Samuel A. Solomon, Minqiang Wang, Jiahong Li, Hong Han, et al.

    Chronic wounds are a major global health challenge associated with substantial economic burden and a negative impact on patient quality of life. Real-time analysis of biomarkers like reactive oxygen and nitrogen species could guide treatment, but existing systems lack the capacity required for continuous monitoring. Wound exudate is secreted slowly and has a complex composition, making efficient fluid collection and real-time analysis challenging. To address these issues, we introduce iCares, a wearable device for wound exudate management and continuous in situ analysis of wound biomarkers. iCares contains a flexible nanoengineered sensor array that measures reactive species such as NO, H 2 O 2 , and O 2 , along with pH and temperature, providing multiparameter data to inform wound status. The device features pump-free triad microfluidic modules with a superhydrophobic-superhydrophilic Janus membrane, bioinspired wedge channels, and three-dimensional graded micropillars for efficient unidirectional exudate collection, transport, and refreshing. The sensors demonstrated a consistent response and analyte selectivity in vitro and in wound exudate. iCares was designed for rapid scalable manufacturing through advanced printing and laser patterning. Wireless connectivity supported long-term continuous monitoring in wounds. The iCares system real-time monitoring was tested in a murine model of diabetic skin wound during infection and antimicrobial treatment. Clinical wound evaluation was conducted in 20 patients with chronic wounds and in two patients before and after surgery. A machine learning analysis of the multiplexed data successfully classified wounds and healing times, indicating that wound exudate analysis by iCares could offer insight into chronic wound status to aid in treatment decisions.


  • Top Cited Papers

    Imaging-guided bioresorbable acoustic hydrogel microrobots

    by Hong Han, Xiaotian Ma, Weiting Deng, Junhang Zhang, Songsong Tang, On Shun Pak, Lailai Zhu, Ernesto Criado-Hidalgo, Chen Gong, Emil Karshalev, et al.

    Micro- and nanorobots excel in navigating the intricate and often inaccessible areas of the human body, offering immense potential for applications such as disease diagnosis, precision drug delivery, detoxification, and minimally invasive surgery. Despite their promise, practical deployment faces hurdles, including achieving stable propulsion in complex in vivo biological environments, real-time imaging and localization through deep tissue, and precise remote control for targeted therapy and ensuring high therapeutic efficacy. To overcome these obstacles, we introduce a hydrogel-based, imaging-guided, bioresorbable acoustic microrobot (BAM) designed to navigate the human body with high stability. Constructed using two-photon polymerization, a BAM comprises magnetic nanoparticles and therapeutic agents integrated into its hydrogel matrix for precision control and drug delivery. The microrobot features an optimized surface chemistry with a hydrophobic inner layer to substantially enhance microbubble retention in biofluids with multiday functionality and a hydrophilic outer layer to minimize aggregation and promote timely degradation. The dual-opening bubble-trapping cavity design enables a BAM to maintain consistent and efficient acoustic propulsion across a range of biological fluids. Under focused ultrasound stimulation, the entrapped microbubbles oscillate and enhance the contrast for real-time ultrasound imaging, facilitating precise tracking and control of BAM movement through wireless magnetic navigation. Moreover, the hydrolysis-driven biodegradability of BAMs ensures its safe dissolution after treatment, posing no risk of long-term residual harm. Thorough in vitro and in vivo experimental evidence demonstrates the promising capabilities of BAMs in biomedical applications. This approach shows promise for advancing minimally invasive medical interventions and targeted therapeutic delivery.


  • Top Cited Papers

    A smart mask for exhaled breath condensate harvesting and analysis

    by Wenzheng Heng, Shukun Yin, Jihong Min, Canran Wang, Hong Han, Ehsan Shirzaei Sani, Jiahong Li, Yu Song, Harry B. Rossiter, Wei Gao

    Recent respiratory outbreaks have garnered substantial attention, yet most respiratory monitoring remains confined to physical signals. Exhaled breath condensate (EBC) harbors rich molecular information that could unveil diverse insights into an individual’s health. Unfortunately, challenges related to sample collection and the lack of on-site analytical tools impede the widespread adoption of EBC analysis. Here, we introduce EBCare, a mask-based device for real-time in situ monitoring of EBC biomarkers. Using a tandem cooling strategy, automated microfluidics, highly selective electrochemical biosensors, and a wireless reading circuit, EBCare enables continuous multimodal monitoring of EBC analytes across real-life indoor and outdoor activities. We validated EBCare’s usability in assessing metabolic conditions and respiratory airway inflammation in healthy participants, patients with chronic obstructive pulmonary disease or asthma, and patients after COVID-19 infection.


  • Open Access

    Combined Effects of Electric Stimulation and Microgrooves in Cardiac Tissue‐on‐a‐Chip for Drug Screening

    by Li Ren, Xingwu Zhou, Rohollah Nasiri, Jun Fang, Xing Jiang, Canran Wang, Moyuan Qu, Haonan Ling, Yihang Chen, Yumeng Xue, et al.

    Animal models and traditional cell cultures are essential tools for drug development. However, these platforms can show striking discrepancies in efficacy and side effects when compared to human trials. These differences can lengthen the drug development process and even lead to drug withdrawal from the market. The establishment of preclinical drug screening platforms that have higher relevancy to physiological conditions is desirable to facilitate drug development. Here, a heart‐on‐a‐chip platform, incorporating microgrooves and electrical pulse stimulations to recapitulate the well‐aligned structure and synchronous beating of cardiomyocytes (CMs) for drug screening, is reported. Each chip is made with facile lithographic and laser‐cutting processes that can be easily scaled up to high‐throughput format. The maturation and phenotypic changes of CMs cultured on the heart‐on‐a‐chip is validated and it can be treated with various drugs to evaluate cardiotoxicity and cardioprotective efficacy. The heart‐on‐a‐chip can provide a high‐throughput drug screening platform in preclinical drug development.