Augusto Rossa Inda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Augusto Rossa Inda has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Bilal Mohamad Ibrahim
LaBiodin Biodynamics Laboratory, Department of Human Movement Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
2 shared publications - Edilson Fernando de Borba
Physical Education Department, Federal University of Paraná, Curitiba 80060-000, PR, Brazil
2 shared publications - Leonardo Alexandre Peyré-Tartaruga
Human Locomotion Laboratory (LOCOLAB), Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Pavia, Italy
2 shared publications - Lucas de Liz Alves
LaBiodin Biodynamics Laboratory, Universidade Federal do Rio Grande do Sul, Porto Alegre 90690-200, Brazil
2 shared publications - Marcus Peikriszwili Tartaruga
Universidade Federal do Paraná, Brasil; Universidade Estadual do Centro-Oeste, Brasil
2 shared publications - Adão Ribeiro Da Silva Neto
LaBiodin Biodynamics Laboratory, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil
1 shared publication
Latest Publications
- 1 January 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. -1 (aop) , 1-10
Agreement and Repeatability of a Smartphone-Based Markerless System (OpenCap) Versus Marker-Based Motion Capture During Treadmill Walking and Running
Marker-based motion capture is the gold standard for 3-dimensional gait analysis but is expensive and largely confined to specialized laboratories. Smartphone-based markerless tools such as OpenCap could scale gait assessment, yet their validity and repeatability during treadmill walking and running remain unclear. We evaluated agreement and within-session repeatability between OpenCap and motion capture during treadmill walking (4 km·h −1 ) and running (8 and 14 km·h −1 ) in 10 healthy adults, recorded simultaneously with both systems. We computed spatiotemporal variables, sagittal hip/knee/ankle angle waveforms and range of motion, and center-of-mass displacement waveforms and range of motion. Agreement was assessed with Bland–Altman, intraclass correlation coefficients, Pearson r , and root mean square error; repeatability with trial-to-trial SD, coefficient of variation, and waveform variability index (GaitSD). Spatiotemporal metrics showed bias close to 0 and very strong associations ( r ≥ .96), with small minimum detectable changes (eg, ≤0.01 m for stride length and ≤0.03 s for temporal variables). Sagittal range of motion showed good-to-excellent reliability (bias: ≈−4.5° to 2.9°, intraclass correlation coefficients = .76–.93). Waveform root mean square error was ≈1° to 4° for joint angles and ≈0.1 to 0.5 cm for center of mass, and statistical parametric mapping indicated only localized differences. Repeatability and GaitSD were comparable between systems across variables and speeds. Under controlled treadmill conditions, OpenCap showed comparable performance and repeatability metrics to motion capture.
- 1 January 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. -1 (aop) , 1-10
Agreement and Repeatability of a Smartphone-Based Markerless System (OpenCap) Versus Marker-Based Motion Capture During Treadmill Walking and Running
Marker-based motion capture is the gold standard for 3-dimensional gait analysis but is expensive and largely confined to specialized laboratories. Smartphone-based markerless tools such as OpenCap could scale gait assessment, yet their validity and repeatability during treadmill walking and running remain unclear. We evaluated agreement and within-session repeatability between OpenCap and motion capture during treadmill walking (4 km·h −1 ) and running (8 and 14 km·h −1 ) in 10 healthy adults, recorded simultaneously with both systems. We computed spatiotemporal variables, sagittal hip/knee/ankle angle waveforms and range of motion, and center-of-mass displacement waveforms and range of motion. Agreement was assessed with Bland–Altman, intraclass correlation coefficients, Pearson r , and root mean square error; repeatability with trial-to-trial SD, coefficient of variation, and waveform variability index (GaitSD). Spatiotemporal metrics showed bias close to 0 and very strong associations ( r ≥ .96), with small minimum detectable changes (eg, ≤0.01 m for stride length and ≤0.03 s for temporal variables). Sagittal range of motion showed good-to-excellent reliability (bias: ≈−4.5° to 2.9°, intraclass correlation coefficients = .76–.93). Waveform root mean square error was ≈1° to 4° for joint angles and ≈0.1 to 0.5 cm for center of mass, and statistical parametric mapping indicated only localized differences. Repeatability and GaitSD were comparable between systems across variables and speeds. Under controlled treadmill conditions, OpenCap showed comparable performance and repeatability metrics to motion capture.
- 1 October 2024
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 40 (5) , 424-431
Fatigue-Related Changes in Running Technique and Mechanical Variables After a Maximal Incremental Test in Recreational Runners
Understanding the changes in running mechanics caused by fatigue is essential to assess its impact on athletic performance. Changes in running biomechanics after constant speed conditions are well documented, but the adaptive responses after a maximal incremental test are unknown. We compared the spatiotemporal, joint kinematics, elastic mechanism, and external work parameters before and after a maximal incremental treadmill test. Eighteen recreational runners performed 2-minute runs at 8 km·h−1 before and after a maximal incremental test on a treadmill. Kinematics, elastic parameters, and external work were determined using the OpenCap and OpenSim software. We did not find differences in spatiotemporal parameters and elastic parameters (mechanical work, ankle, and knee motion range) between premaximal and postmaximal test conditions. After the maximal test, the runners flexed their hips more at contact time (19.4°–20.6°, P = .013) and presented a larger range of pelvis rotation at the frontal plane (10.3°–11.4°, P = .002). The fatigue applied in the test directly affects pelvic movements; however, it does not change the lower limb motion or the spatiotemporal and mechanical work parameters in recreational runners. A larger frontal plane motion of the pelvis deserves attention due to biomechanical risk factors associated with injuries.
- 1 October 2024
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 40 (5) , 424-431
Fatigue-Related Changes in Running Technique and Mechanical Variables After a Maximal Incremental Test in Recreational Runners
Understanding the changes in running mechanics caused by fatigue is essential to assess its impact on athletic performance. Changes in running biomechanics after constant speed conditions are well documented, but the adaptive responses after a maximal incremental test are unknown. We compared the spatiotemporal, joint kinematics, elastic mechanism, and external work parameters before and after a maximal incremental treadmill test. Eighteen recreational runners performed 2-minute runs at 8 km·h−1 before and after a maximal incremental test on a treadmill. Kinematics, elastic parameters, and external work were determined using the OpenCap and OpenSim software. We did not find differences in spatiotemporal parameters and elastic parameters (mechanical work, ankle, and knee motion range) between premaximal and postmaximal test conditions. After the maximal test, the runners flexed their hips more at contact time (19.4°–20.6°, P = .013) and presented a larger range of pelvis rotation at the frontal plane (10.3°–11.4°, P = .002). The fatigue applied in the test directly affects pelvic movements; however, it does not change the lower limb motion or the spatiotemporal and mechanical work parameters in recreational runners. A larger frontal plane motion of the pelvis deserves attention due to biomechanical risk factors associated with injuries.