LRLiz Robinson

Liz Robinson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liz Robinson has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Variation in IRT in Different Ethnic Groups in England—Implications for a Newborn Screening Programme for CF in Diverse Multiethnic Populations

    by Toby Greenfield, Lesley Tetlow, James R. Bonham, Catherine Collingwood, Laura Wainwright, Liz Robinson, Dave Wright, Beverly Hird, Tejswurree Ramgoolam, Caroline Griffith, et al.

    Increasing ethnic diversity raises potential inequalities within screening programmes. In the UK, newborns are screened for CF by initially measuring IRT. Dried blood spot IRT levels above a set cut-off require follow-up testing to establish a screening result. Variation exists in IRT levels between different ethnicities and therefore impacts the number of potentially false positive results obtained from ethnic groups. Over a 4-year period, IRT data was collected, and the 99.5th centile was calculated for different ethnic groups. Significant differences were noticed between ethnic groups, and the CF outcome data over a 10-year period were then analysed to establish the effect this had on positive predictive values. The largest difference in IRT 99.5th centile values was seen between the White British and Black African groups. Positive predictive values for Black African and Indian ethnic groups were much lower than the other groups. Rather than try to incorporate ethnicity into the UK CF screening algorithm, we suggest making CF clinicians aware of the differences between different ethnic groups to inform counselling families who receive screen-positive results.


  • Open Access

    Consistency in the Assessment of Dried Blood Spot Specimen Size and Quality in U.K. Newborn Screening Laboratories

    by Stuart J. Moat, James R. Bonham, Christine Cavanagh, Margaret Birch, Caroline Griffith, Lynette Shakespeare, Clare Le Masurier, Claire Manfredonia, Beverly Hird, Philippa Goddard, et al.

    In 2015, U.K. newborn screening (NBS) laboratory guidelines were introduced to standardize dried blood spot (DBS) specimen quality acceptance and specify a minimum acceptable DBS diameter of ≥7 mm. The UK ‘acceptable’ avoidable repeat rate (AVRR) is ≤2%. To assess inter-laboratory variability in specimen acceptance/rejection, two sets of colored scanned images (n = 40/set) of both good and poor-quality DBS specimens were distributed to all 16 U.K. NBS laboratories for evaluation as part of an external quality assurance (EQA) assessment. The mean (range) number of specimens rejected in the first EQA distribution was 7 (1–16) and in the second EQA distribution was 7 (0–16), demonstrating that adherence to the 2015 guidelines was highly variable. A new minimum standard for DBS size of ≥8 mm (to enable a minimum of six sub-punches from two DBS) was discussed. NBS laboratories undertook a prospective audit and demonstrated that using ≥8 mm as the minimum acceptable DBS diameter would increase the AVRR from 2.1% (range 0.55% to 5.5%) to 7.8% (range 0.55% to 22.7%). A significant inverse association between the number of specimens rejected in the DBS EQA distributions and the predicted AVVR (using ≥8 mm minimum standard) was observed (r = −0.734, p = 0.003). Before implementing more stringent standards, the impact of a standard operating procedure (SOP) designed to enable a standardized approach of visual assessment and using the existing ≥7 mm diameter (to enable a minimum of four sub-punches from two DBS) as the minimum standard was assessed in a retrospective audit. Implementation of the SOP and using the ≥7 mm DBS diameter would increase the AVRR from 2.3% (range 0.63% to 5.3%) to 6.5% (range 4.3% to 20.9%). The results demonstrate that there is inconsistency in applying the acceptance/rejection criteria, and that a low AVVR is not an indication of good-quality specimens being received into laboratories. Further work is underway to introduce and maintain standards without increasing the AVRR to unacceptable levels.