Dalton Berri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dalton Berri has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Adriana Yuriko Koga
Post-Graduate Program of Health Sciences State University of Ponta Grossa Ponta Grossa 84030-900 Brazil
2 shared publications - Conrado Auer Trentini
Department of Medicine, Universidade Estadual de Ponta Grossa, Ponta Grossa, PR, Brazil
2 shared publications - Elcio Machinski
Universidade Estadual de Ponta Grossa
2 shared publications - Leandro Cavalcante Lipinski
Post-Graduate Program of Health Sciences State University of Ponta Grossa Ponta Grossa 84030-900 Brazil
2 shared publications - Paulo Vitor Farago
Universidade Estadual de Ponta Grossa
2 shared publications - Débora Melo Mazzo
Universidade Estadual de Ponta Grossa
1 shared publication
Latest Publications
- Open Access
- 1 April 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (02) , 001-007
A aplicação tópica de nanocápsulas de estrogênio na incisão cutânea melhora a Consolidação de fraturas em ratas osteoporóticas
Resumo: Objetivo O desafio de consolidação de fraturas osteoporóticas, particularmente exacerbadas pela deficiência de estrogênio pós-menopausa, ressalta a necessidade urgente de intervenções eficazes. Este estudo tem como objetivo avaliar o impacto do estrogênio administrado localmente via nanocápsulas na consolidação de fraturas osteoporóticas em ratas ovariectomizadas e analisar os efeitos sistêmicos deste hormônio usando o útero como órgão sentinela. Métodos Quarenta e cinco animais foram submetidos a fraturas femorais padronizadas e divididos em três grupos: G1 (controle), G2 (estrogênio convencional) e G3 (nanocápsulas de estrogênio). O estrogênio foi aplicado topicamente na região da incisão da pele (área tricotomizada). A cicatrização da fratura foi avaliada 15 e 30 dias após a fratura por meio de análises radiográficas e histológicas. A histologia uterina analisou os efeitos sistêmicos. Resultados Na análise radiográfica dos calos ósseos, G3 (8,75 ± 0,77 mm) exibiu formação de calo significativamente maior do que o grupo controle (7,18 ± 0,4 mm) no dia 15 e a análise histológica revelou aumento da formação de calo em G3 no dia 30, indicando um processo de cicatrização acelerado. Além disso, a análise histológica uterina no dia 30 mostrou uma redução na espessura endometrial em G3 (510.073 ± 54.705,11 μm) em comparação a G2 (623.729 ± 101.592 μm). Conclusão Estes achados sugerem que nanocápsulas tópicas de estrogênio podem aumentar a formação de calos no tratamento de fraturas femorais osteoporóticas em ratas, potencialmente com menos efeitos sistêmicos.
- 1 April 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (02) , 001-007
Open AccessA aplicação tópica de nanocápsulas de estrogênio na incisão cutânea melhora a Consolidação de fraturas em ratas osteoporóticas
Resumo: Objetivo O desafio de consolidação de fraturas osteoporóticas, particularmente exacerbadas pela deficiência de estrogênio pós-menopausa, ressalta a necessidade urgente de intervenções eficazes. Este estudo tem como objetivo avaliar o impacto do estrogênio administrado localmente via nanocápsulas na consolidação de fraturas osteoporóticas em ratas ovariectomizadas e analisar os efeitos sistêmicos deste hormônio usando o útero como órgão sentinela. Métodos Quarenta e cinco animais foram submetidos a fraturas femorais padronizadas e divididos em três grupos: G1 (controle), G2 (estrogênio convencional) e G3 (nanocápsulas de estrogênio). O estrogênio foi aplicado topicamente na região da incisão da pele (área tricotomizada). A cicatrização da fratura foi avaliada 15 e 30 dias após a fratura por meio de análises radiográficas e histológicas. A histologia uterina analisou os efeitos sistêmicos. Resultados Na análise radiográfica dos calos ósseos, G3 (8,75 ± 0,77 mm) exibiu formação de calo significativamente maior do que o grupo controle (7,18 ± 0,4 mm) no dia 15 e a análise histológica revelou aumento da formação de calo em G3 no dia 30, indicando um processo de cicatrização acelerado. Além disso, a análise histológica uterina no dia 30 mostrou uma redução na espessura endometrial em G3 (510.073 ± 54.705,11 μm) em comparação a G2 (623.729 ± 101.592 μm). Conclusão Estes achados sugerem que nanocápsulas tópicas de estrogênio podem aumentar a formação de calos no tratamento de fraturas femorais osteoporóticas em ratas, potencialmente com menos efeitos sistêmicos.
- Open Access
- 1 April 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (02) , 001-007
Topical Application of Estrogen Nanocapsules on Skin Incision Improves Fracture Healing in Osteoporotic Rats
Objective The challenge of consolidating osteoporotic fractures, particularly exacerbated by postmenopausal estrogen deficiency, underscores the urgent need for effective interventions. This study aims to evaluate the impact of locally administered estrogen via nanocapsules on the consolidation of osteoporotic fractures in ovariectomized rats, while also assessing the systemic effects of this hormone, using the uterus as a sentinel organ. Methods Forty-five animals underwent standardized femoral fractures and were divided into three groups: G1 (control), G2 (conventional estrogen), and G3 (estrogen nanocapsules). The estrogen was applied topically to the skin incision region (trichotomized area). Fracture healing was assessed at 15- and 30-days postfracture through radiographic and histological analyses, with uterine histology conducted to evaluate systemic effects. Results In terms of radiographic analysis of callus formation, G3 (8.75 ± 0.77 mm) exhibited significantly higher callus formation than the control group (7.18 ± 0.4 mm) at day 15, with histological analysis revealing increased callus formation in G3 at day 30, indicating an accelerated healing process. Furthermore, uterine histological analysis at day 30 showed a reduction in endometrial thickness in G3 (510,073 ± 54,705.11 μm) compared with G2 (623,729 ± 101,592 μm). Conclusion These findings suggest that topical estrogen nanocapsules may enhance callus formation in the treatment of osteoporotic femoral fractures in rats, potentially with fewer systemic effects.
- 1 April 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (02) , 001-007
Open AccessTopical Application of Estrogen Nanocapsules on Skin Incision Improves Fracture Healing in Osteoporotic Rats
Objective The challenge of consolidating osteoporotic fractures, particularly exacerbated by postmenopausal estrogen deficiency, underscores the urgent need for effective interventions. This study aims to evaluate the impact of locally administered estrogen via nanocapsules on the consolidation of osteoporotic fractures in ovariectomized rats, while also assessing the systemic effects of this hormone, using the uterus as a sentinel organ. Methods Forty-five animals underwent standardized femoral fractures and were divided into three groups: G1 (control), G2 (conventional estrogen), and G3 (estrogen nanocapsules). The estrogen was applied topically to the skin incision region (trichotomized area). Fracture healing was assessed at 15- and 30-days postfracture through radiographic and histological analyses, with uterine histology conducted to evaluate systemic effects. Results In terms of radiographic analysis of callus formation, G3 (8.75 ± 0.77 mm) exhibited significantly higher callus formation than the control group (7.18 ± 0.4 mm) at day 15, with histological analysis revealing increased callus formation in G3 at day 30, indicating an accelerated healing process. Furthermore, uterine histological analysis at day 30 showed a reduction in endometrial thickness in G3 (510,073 ± 54,705.11 μm) compared with G2 (623,729 ± 101,592 μm). Conclusion These findings suggest that topical estrogen nanocapsules may enhance callus formation in the treatment of osteoporotic femoral fractures in rats, potentially with fewer systemic effects.
- Open Access
- 15 October 2024
- Published by NEPAS in ABCS Health Sciences
- Vol. 49, e024217
Effect of kinesio tape application on the lymphatic system during knee arthroscopy surgery
Introduction: To control edema, physical therapy employs several techniques, such as elastic bandages application - Kinesio tape (KT) - to block or drain subcutaneous body fluids, due to the secondary effects of its elastic properties. Objective: To evaluate the effect kinesio tape application on the lymphatic system during knee arthroscopy surgery. Methods: Controlled clinical trial, with 28 patients, alternately divided into two groups (intervention and control) referred to arthroscopic surgical treatment of anterior cruciate ligament and meniscus injuries. Patients were evaluated in the preoperative and, on the 1st postoperative day, while the intervention group received KT application for the lymphatic system in the intraoperative period. Results: The intervention group showed statistically significant results in the non-formation of edema, according to perimetric (Point 2: p=0.010, Point 3: p≤0.001 and Point 4: p≤0.001) and ultrasound (p=0.007) analyses when compared to the control group. On the other hand, pain (p=0.056) did not present a significant difference, but in the intragroup comparison pre and postoperative, a considerable reduction (p=0.002) was observed. Conclusion: KT application for the lymphatic system in the intraoperative period of knee arthroscopy effectively minimized edema formation and reduced pain.
- 15 October 2024
- Published by NEPAS in ABCS Health Sciences
- Vol. 49, e024217
Open AccessEffect of kinesio tape application on the lymphatic system during knee arthroscopy surgery
Introduction: To control edema, physical therapy employs several techniques, such as elastic bandages application - Kinesio tape (KT) - to block or drain subcutaneous body fluids, due to the secondary effects of its elastic properties. Objective: To evaluate the effect kinesio tape application on the lymphatic system during knee arthroscopy surgery. Methods: Controlled clinical trial, with 28 patients, alternately divided into two groups (intervention and control) referred to arthroscopic surgical treatment of anterior cruciate ligament and meniscus injuries. Patients were evaluated in the preoperative and, on the 1st postoperative day, while the intervention group received KT application for the lymphatic system in the intraoperative period. Results: The intervention group showed statistically significant results in the non-formation of edema, according to perimetric (Point 2: p=0.010, Point 3: p≤0.001 and Point 4: p≤0.001) and ultrasound (p=0.007) analyses when compared to the control group. On the other hand, pain (p=0.056) did not present a significant difference, but in the intragroup comparison pre and postoperative, a considerable reduction (p=0.002) was observed. Conclusion: KT application for the lymphatic system in the intraoperative period of knee arthroscopy effectively minimized edema formation and reduced pain.