Joshua Eger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joshua Eger has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Jennifer Blain Christen
3 shared publicationsAkshansh Kaushik
2 shared publications- Jennifer Blain Christen
Arizona State University
2 shared publications Karen S. Anderson
2 shared publications- Karen. S. Anderson
Arizona State University
2 shared publications - Pankaj Kumar
All India Institute of Medical Sciences, New Delhi, India
2 shared publications
Latest Publications
- 1 October 2025
- Published by American Society of Clinical Oncology (ASCO) in JCO Global Oncology
- Vol. 11 (11) , e2500117
Diagnostic Translational Considerations for Global Health Settings: Portable Detection of Human Papillomavirus for Cervical Cancer Screening in India
PURPOSE: Translation of diagnostic technology developed at the laboratory bench involves iterations of user feedback and design modifications. Learning about translational requirements early in the design process facilitates the development of feasible prototypes that have a better likelihood of implementation in global health settings. During our development of a portable system to detect human papillomavirus (HPV) for cervical cancer screening in India, we encountered and solved issues related to research translation. We report our findings to help others deploying diagnostic technology for global health. MATERIALS AND METHODS: We designed a point-of-care system to process patient samples and diagnose HPV infection in the cervix. We continually shipped components of the system from the United States to our collaborating team in India to assess component condition and usability at the local site. We simultaneously developed HPV isothermal amplification assays that were fit for purpose. Cervical brush samples were used in our portable system for functional validation. RESULTS: We found ideal transport methods to ensure component quality and reagent stability through the international shipment chain. Portable systems should be designed as simple as possible for correct usage at the local testing site. Usability tests drove our design improvements from 28% to 93% success rates. We demonstrated proof-of-concept functionality of our portable system for 13 cervical brush samples on-site, with a sensitivity of 100% and specificity of 88.9%. CONCLUSION: Issues related to technology transfer for global health settings manifest during distribution and deployment of prototypes. We identified several issues during our synergistic design process and report recommendations on the basis of our experience.
- 1 October 2025
- Published by American Society of Clinical Oncology (ASCO) in JCO Global Oncology
- Vol. 11 (11) , e2500117
Diagnostic Translational Considerations for Global Health Settings: Portable Detection of Human Papillomavirus for Cervical Cancer Screening in India
PURPOSE: Translation of diagnostic technology developed at the laboratory bench involves iterations of user feedback and design modifications. Learning about translational requirements early in the design process facilitates the development of feasible prototypes that have a better likelihood of implementation in global health settings. During our development of a portable system to detect human papillomavirus (HPV) for cervical cancer screening in India, we encountered and solved issues related to research translation. We report our findings to help others deploying diagnostic technology for global health. MATERIALS AND METHODS: We designed a point-of-care system to process patient samples and diagnose HPV infection in the cervix. We continually shipped components of the system from the United States to our collaborating team in India to assess component condition and usability at the local site. We simultaneously developed HPV isothermal amplification assays that were fit for purpose. Cervical brush samples were used in our portable system for functional validation. RESULTS: We found ideal transport methods to ensure component quality and reagent stability through the international shipment chain. Portable systems should be designed as simple as possible for correct usage at the local testing site. Usability tests drove our design improvements from 28% to 93% success rates. We demonstrated proof-of-concept functionality of our portable system for 13 cervical brush samples on-site, with a sensitivity of 100% and specificity of 88.9%. CONCLUSION: Issues related to technology transfer for global health settings manifest during distribution and deployment of prototypes. We identified several issues during our synergistic design process and report recommendations on the basis of our experience.
- Open Access
- 3 February 2025
- Published by Open Engineering Inc in engrXiv
Low-Cost, Open-Source Colorimetric Platform for Point-of-Care (POC) anti-Human Papillomavirus Type 16 (HPV16) Antibody Detection
Human papillomavirus (HPV) is a leading cause of anogenital and head and neck cancers. HPV type 16 (HPV16) is a significant high-risk strain due to its strong association with these malignancies. The burden of HPV-related cancers is particularly severe in low and middle-income countries (LMICs), where access to diagnostic tools is limited. This work introduces a low-cost, point-of-care (POC) colorimetric platform for detection of antibodies against HPV16. The lateral flow immunoassay (LFIA) developed uses immobilized HPV16 CE2 and E7 proteins for antibody capture and colloidal gold-conjugated secondary for colorimetric labeling. Quantitative readout is achieved via an imaging device that incorporates open-source electronics and 3D-printed components. Analytical sensitivity experiments determined a limit of detection (LOD) at 46 ng/mL. Clinical evaluation of plasma samples (n = 20) from head and neck cancer patients (n = 15) and healthy individuals (n = 5) yielded 94.7% sensitivity, 90.5% specificity, and 92.5% overall accuracy. This study identified a moderate-to-high prevalence of anti-HPV16 antibodies in head and neck cancer patients, with 66.7% testing positive. These results suggest that our platform is a viable tool for detection of anti-HPV16 antibodies, particularly in resource-limited settings where cost-effectiveness and accessibility are crucial.
- 3 February 2025
- Published by Open Engineering Inc in engrXiv
Open AccessLow-Cost, Open-Source Colorimetric Platform for Point-of-Care (POC) anti-Human Papillomavirus Type 16 (HPV16) Antibody Detection
Human papillomavirus (HPV) is a leading cause of anogenital and head and neck cancers. HPV type 16 (HPV16) is a significant high-risk strain due to its strong association with these malignancies. The burden of HPV-related cancers is particularly severe in low and middle-income countries (LMICs), where access to diagnostic tools is limited. This work introduces a low-cost, point-of-care (POC) colorimetric platform for detection of antibodies against HPV16. The lateral flow immunoassay (LFIA) developed uses immobilized HPV16 CE2 and E7 proteins for antibody capture and colloidal gold-conjugated secondary for colorimetric labeling. Quantitative readout is achieved via an imaging device that incorporates open-source electronics and 3D-printed components. Analytical sensitivity experiments determined a limit of detection (LOD) at 46 ng/mL. Clinical evaluation of plasma samples (n = 20) from head and neck cancer patients (n = 15) and healthy individuals (n = 5) yielded 94.7% sensitivity, 90.5% specificity, and 92.5% overall accuracy. This study identified a moderate-to-high prevalence of anti-HPV16 antibodies in head and neck cancer patients, with 66.7% testing positive. These results suggest that our platform is a viable tool for detection of anti-HPV16 antibodies, particularly in resource-limited settings where cost-effectiveness and accessibility are crucial.
- Open Access
- 1 February 2025
- Published by SAGE Publications in Cancer Biomarkers
- Vol. 42 (2)
Development of a multiplexed lateral flow assay for the serologic detection of HPV-associated head and neck cancer
Background: Among head and neck squamous cell carcinomas (HNSCCs), the incidence of oropharyngeal cancer (OPC) has been increasing in recent decades. Human papillomavirus (HPV) type 16 is associated with the majority of OPC. Circulating antibodies (Abs) to multiple HPV16 early antigens, including E2, E6, and E7, have been detected in patient sera, and are strongly associated with risk for OPC. However, HPV serology currently requires laboratory-based tests that are difficult to implement for large-scale cancer screening. Objective: The goal of this study was to develop and validate a point-of-care assay for rapid detection of circulating IgG to HPV16 early antigens. Methods: We measured Abs to HPV16 E2, E6, and E7 proteins using a lateral flow assay (LFA) in sera from 119 newly diagnosed OPC cases, 41 partners, and 81 healthy volunteers. The 119 patients with HPV-OPC were classified as HPV-positive based on in situ hybridization (ISH) or institutional p16 immunohistochemistry. The sensitivity and specificity of the LFA were determined by comparing to clinical diagnosis. Results: The specificity for each individual HPV16 E2, E6, and E7 antibodies was 95.1% (77/81), 96.3% (78/81), and 98.7% (80/81), respectively. The sensitivities of the individual HPV16 antibodies were as follows: E2, 47.9% (57/119), E6, 31.9% (38/119), and E7, 57.1% (68/119). The 3-biomarker panel (at least one positive for E2, E6, and E7 Abs) demonstrated a sensitivity of 76.5% (91/119) and a specificity of 92.6% (75/81). Conclusions: We developed a multiplexed lateral flow assay for the rapid detection of serologic responses to HPV16. Further research is required to determine the utility of these tests for HPV + HNSCC cancer screening, as higher specificity, and an assessment of the benefits of positive test results have yet to be evaluated in this context.
- 1 February 2025
- Published by SAGE Publications in Cancer Biomarkers
- Vol. 42 (2)
Open AccessDevelopment of a multiplexed lateral flow assay for the serologic detection of HPV-associated head and neck cancer
Background: Among head and neck squamous cell carcinomas (HNSCCs), the incidence of oropharyngeal cancer (OPC) has been increasing in recent decades. Human papillomavirus (HPV) type 16 is associated with the majority of OPC. Circulating antibodies (Abs) to multiple HPV16 early antigens, including E2, E6, and E7, have been detected in patient sera, and are strongly associated with risk for OPC. However, HPV serology currently requires laboratory-based tests that are difficult to implement for large-scale cancer screening. Objective: The goal of this study was to develop and validate a point-of-care assay for rapid detection of circulating IgG to HPV16 early antigens. Methods: We measured Abs to HPV16 E2, E6, and E7 proteins using a lateral flow assay (LFA) in sera from 119 newly diagnosed OPC cases, 41 partners, and 81 healthy volunteers. The 119 patients with HPV-OPC were classified as HPV-positive based on in situ hybridization (ISH) or institutional p16 immunohistochemistry. The sensitivity and specificity of the LFA were determined by comparing to clinical diagnosis. Results: The specificity for each individual HPV16 E2, E6, and E7 antibodies was 95.1% (77/81), 96.3% (78/81), and 98.7% (80/81), respectively. The sensitivities of the individual HPV16 antibodies were as follows: E2, 47.9% (57/119), E6, 31.9% (38/119), and E7, 57.1% (68/119). The 3-biomarker panel (at least one positive for E2, E6, and E7 Abs) demonstrated a sensitivity of 76.5% (91/119) and a specificity of 92.6% (75/81). Conclusions: We developed a multiplexed lateral flow assay for the rapid detection of serologic responses to HPV16. Further research is required to determine the utility of these tests for HPV + HNSCC cancer screening, as higher specificity, and an assessment of the benefits of positive test results have yet to be evaluated in this context.
- 31 October 2024
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (11) , 2060-2077
Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings
The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination. Remarkably, there was no measurable degradation over a 3-year study. Precise photoluminescence intensity modulation was accomplished with neutral density gel filters (R2 > 0.9982) and optical apertures (R2 > 0.9970). A model for photoluminescence intensity as a function of neutral-density filter and optical aperture parameters yielded a mean percentage error (MPE) of 2.79%, indicating high precision. Inter-sample variability was low, with a mean coefficient of variation (CV) of 1.32%. Mean CV across 24 channels decreased from 11.88% to 1.51% following multi-point calibration of multichannel point-of-care (POC) fluorometers. Cost analysis revealed a per-unit cost between $0.49 to $1.80. This work suggests that the proposed calibration standards provide a cost-effective, highly stable solution for reliable fluorometer calibration in low-resource settings.
- 31 October 2024
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (11) , 2060-2077
Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings
The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination. Remarkably, there was no measurable degradation over a 3-year study. Precise photoluminescence intensity modulation was accomplished with neutral density gel filters (R2 > 0.9982) and optical apertures (R2 > 0.9970). A model for photoluminescence intensity as a function of neutral-density filter and optical aperture parameters yielded a mean percentage error (MPE) of 2.79%, indicating high precision. Inter-sample variability was low, with a mean coefficient of variation (CV) of 1.32%. Mean CV across 24 channels decreased from 11.88% to 1.51% following multi-point calibration of multichannel point-of-care (POC) fluorometers. Cost analysis revealed a per-unit cost between $0.49 to $1.80. This work suggests that the proposed calibration standards provide a cost-effective, highly stable solution for reliable fluorometer calibration in low-resource settings.
- Open Access
- 6 September 2024
- Published by Open Engineering Inc in engrXiv
Analysis of Nitrocellulose-Based Solid-State Calibration Standards for Point-of-Care (POC) Fluorometers
This study presents an analysis of nitrocellulose-based solid-state calibration standards for point-of-care (POC) fluorometers. Our findings show that the manual assembly process introduces significant variations in the alignment/offset of printed lines with respect to the optical aperture. A Claremont BioSolutions and BioDot automated dispenser were compared to determine efficacy in producing high-quality calibration standards. Qualitative analysis of line morphology shows less pronounced irregularities in lines printed by the BioDot. The BioDot also demonstrated significantly lower variation in the width of printed lines, with a CV of 6.4% compared to the Claremont’s 27.0%. However, fluorescence intensity measurements using a POC fluorometer revealed a mean inter-sample CV of 15.0% and 14.2% for the Claremont and BioDot, respectively. Direct and indirect fluorophore immobilization methods were compared. The results indicated that the direct method is a viable approach, but the indirect method presents challenges with increased background and fluorophore depletion, rendering it unsuitable for calibration standard production.
- 6 September 2024
- Published by Open Engineering Inc in engrXiv
Open AccessAnalysis of Nitrocellulose-Based Solid-State Calibration Standards for Point-of-Care (POC) Fluorometers
This study presents an analysis of nitrocellulose-based solid-state calibration standards for point-of-care (POC) fluorometers. Our findings show that the manual assembly process introduces significant variations in the alignment/offset of printed lines with respect to the optical aperture. A Claremont BioSolutions and BioDot automated dispenser were compared to determine efficacy in producing high-quality calibration standards. Qualitative analysis of line morphology shows less pronounced irregularities in lines printed by the BioDot. The BioDot also demonstrated significantly lower variation in the width of printed lines, with a CV of 6.4% compared to the Claremont’s 27.0%. However, fluorescence intensity measurements using a POC fluorometer revealed a mean inter-sample CV of 15.0% and 14.2% for the Claremont and BioDot, respectively. Direct and indirect fluorophore immobilization methods were compared. The results indicated that the direct method is a viable approach, but the indirect method presents challenges with increased background and fluorophore depletion, rendering it unsuitable for calibration standard production.