Gabriele Partesotti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gabriele Partesotti has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Felix Reimold
Max-Planck-Institut für Plasmaphysik
8 shared publications - Daihong Zhang
Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany
7 shared publications - Byron J. Peterson
National Institute for Fusion Science, Toki, Japan
6 shared publications - Kiyofumi Mukai
National Institute for Fusion Science, National Institutes of Natural Sciences
6 shared publications - Anastasios Tsikouras
Max Planck Institute for Plasma Physics
4 shared publications - Glen Anthony Wurden
Los Alamos National Laboratory, Los Alamos, NM, United States of America
4 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 67 (1) , 016035
Effect of NBI on thermal quench dynamics in TCV disruptions
A neutral beam injection (NBI) heat deposition model is implemented in the Disruption Runaway Electron Analysis Model ( Dream ), accounting for the attenuation of the neutral beam particles, the resulting beam shine-through, and the partition of deposited energy between electrons and ions. The NBI model is applied to three TCV disruption discharges (# 86634 , # 86645 , and # 86654 ) with different amounts of injected NBI power, and bayesian inference is used to constrain the heat transport and neon injection parameters. Sets of parameters are found which allow the simulations to reproduce the experimentally measured electron temperature, radiated power, and initial line-integrated density. The final runaway electron density is shown to be only weakly affected by NBI, and further comparisons between fluid and kinetic simulations indicate that a slight reduction in early runaway generation can be followed by enhanced runaway production at later times. Extrapolation to ITER also suggests that unrealistically large NBI powers would be required to produce a comparable effect. These results indicate that NBI can affect disruption dynamics in small and medium-size tokamaks, but is insufficient to affect the thermal quench dynamics in reactor-scale tokamaks.
- 9 November 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 67 (1) , 016035
Open AccessEffect of NBI on thermal quench dynamics in TCV disruptions
A neutral beam injection (NBI) heat deposition model is implemented in the Disruption Runaway Electron Analysis Model ( Dream ), accounting for the attenuation of the neutral beam particles, the resulting beam shine-through, and the partition of deposited energy between electrons and ions. The NBI model is applied to three TCV disruption discharges (# 86634 , # 86645 , and # 86654 ) with different amounts of injected NBI power, and bayesian inference is used to constrain the heat transport and neon injection parameters. Sets of parameters are found which allow the simulations to reproduce the experimentally measured electron temperature, radiated power, and initial line-integrated density. The final runaway electron density is shown to be only weakly affected by NBI, and further comparisons between fluid and kinetic simulations indicate that a slight reduction in early runaway generation can be followed by enhanced runaway production at later times. Extrapolation to ITER also suggests that unrealistically large NBI powers would be required to produce a comparable effect. These results indicate that NBI can affect disruption dynamics in small and medium-size tokamaks, but is insufficient to affect the thermal quench dynamics in reactor-scale tokamaks.
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Upgrade of the RADCAM diagnostic for the TCV tokamak with tangential bolometer sightlines
The plasma radiated power is a crucial component of transport and power balance analysis in modern fusion devices. In the Tokamak à Configuration Variable (TCV), radiated power inferences are currently provided by the RADCAM diagnostic. As part of a recent upgrade, two new bolometer arrays are being added to the system to improve both toroidal coverage and tomographic accuracy. This work details the principal elements of their preliminary design, the selection of views, and the proof of concept. The desired viewing geometry was modeled using ray tracing optimized to improve reconstructions. Synthetic emissivity distributions were used to assess the expected bolometer response and the inversion accuracy of the upgraded system. The technical design of the new bolometers is ongoing. Installation and exploitation is expected to take place by the end of 2026.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessUpgrade of the RADCAM diagnostic for the TCV tokamak with tangential bolometer sightlines
The plasma radiated power is a crucial component of transport and power balance analysis in modern fusion devices. In the Tokamak à Configuration Variable (TCV), radiated power inferences are currently provided by the RADCAM diagnostic. As part of a recent upgrade, two new bolometer arrays are being added to the system to improve both toroidal coverage and tomographic accuracy. This work details the principal elements of their preliminary design, the selection of views, and the proof of concept. The desired viewing geometry was modeled using ray tracing optimized to improve reconstructions. Synthetic emissivity distributions were used to assess the expected bolometer response and the inversion accuracy of the upgraded system. The technical design of the new bolometers is ongoing. Installation and exploitation is expected to take place by the end of 2026.
- Open Access
- 1 August 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (8) , 085004
Improved feedback control of the radiated power in Wendelstein 7-X using system identification
The W7-X stellarator was recently upgraded with a new feedback control system for the radiated power. The radiated power, observed using bolometer cameras, is controlled using injection of impurities from the gas valve system. For designing a controller, system identification techniques were employed. These identify the response of the radiation to impurity seeding for specific plasma parameters. Using the obtained frequency response data, a controller was designed which provided accurate control of the radiated power. The system was able to reach and reliably maintain different setpoints using N 2 and Ne for the injection, both for attached and detached conditions. It enabled stable long pulse detached operation and multiple steady state radiated power levels during discharges. This allowed heat load mitigation during long discharges ( > 300 s), as well as studying the plasma in different radiative regimes efficiently.
- 1 August 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (8) , 085004
Open AccessImproved feedback control of the radiated power in Wendelstein 7-X using system identification
The W7-X stellarator was recently upgraded with a new feedback control system for the radiated power. The radiated power, observed using bolometer cameras, is controlled using injection of impurities from the gas valve system. For designing a controller, system identification techniques were employed. These identify the response of the radiation to impurity seeding for specific plasma parameters. Using the obtained frequency response data, a controller was designed which provided accurate control of the radiated power. The system was able to reach and reliably maintain different setpoints using N 2 and Ne for the injection, both for attached and detached conditions. It enabled stable long pulse detached operation and multiple steady state radiated power levels during discharges. This allowed heat load mitigation during long discharges ( > 300 s), as well as studying the plasma in different radiative regimes efficiently.
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
Gaussian process regression for thermal transport analysis in infrared imaging video bolometry
Accurate characterization of thermal diffusion and blackbody radiation on the detector foil is crucial in infrared imaging video bolometry (IRVB) for reliably inferring the spatial distribution of plasma radiation. This paper presents a new inference framework for modeling blackbody radiation and thermal diffusion power densities using Gaussian process regression. This method is validated with both synthetic and experimental IRVB data, producing reliable results without the need for temporal or spatial averaging. In addition, the effects of noise level and foil material are analyzed, and both the limitations of this framework and strategies for improving its performance are identified.
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
Gaussian process regression for thermal transport analysis in infrared imaging video bolometry
Accurate characterization of thermal diffusion and blackbody radiation on the detector foil is crucial in infrared imaging video bolometry (IRVB) for reliably inferring the spatial distribution of plasma radiation. This paper presents a new inference framework for modeling blackbody radiation and thermal diffusion power densities using Gaussian process regression. This method is validated with both synthetic and experimental IRVB data, producing reliable results without the need for temporal or spatial averaging. In addition, the effects of noise level and foil material are analyzed, and both the limitations of this framework and strategies for improving its performance are identified.
- Open Access
- 6 January 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (2) , 026021
Correlation between radiated power and target heat flux in the island divertor of W7-X
Radiative losses from the plasma represent a key component of global power balance in a magnetic confinement fusion device. Measurements of the plasma radiation and its spatial distribution are essential for physical studies and to ensure safe machine operation. Here, an imaging bolometer diagnostic is employed to characterize the plasma radiated power in the island divertor of the large Wendelstein 7-X (W7-X) stellarator device. In attached plasmas, the divertor radiation pattern exhibits magnetic field-aligned stripes and a toroidally non-uniform character highly correlated with the target power load deposition pattern of the given magnetic field configuration. Toroidal uniformity of the plasma emissivity is partly recovered in detached discharges. Similar results are found in EMC3-EIRENE simulations of carbon impurity radiation, which indicate that the steep toroidal emissivity gradients observed in the experiment (factor ×2 change over 10 cm parallel distance) are supported by toroidally localized particle sources.
- 6 January 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (2) , 026021
Open AccessCorrelation between radiated power and target heat flux in the island divertor of W7-X
Radiative losses from the plasma represent a key component of global power balance in a magnetic confinement fusion device. Measurements of the plasma radiation and its spatial distribution are essential for physical studies and to ensure safe machine operation. Here, an imaging bolometer diagnostic is employed to characterize the plasma radiated power in the island divertor of the large Wendelstein 7-X (W7-X) stellarator device. In attached plasmas, the divertor radiation pattern exhibits magnetic field-aligned stripes and a toroidally non-uniform character highly correlated with the target power load deposition pattern of the given magnetic field configuration. Toroidal uniformity of the plasma emissivity is partly recovered in detached discharges. Similar results are found in EMC3-EIRENE simulations of carbon impurity radiation, which indicate that the steep toroidal emissivity gradients observed in the experiment (factor ×2 change over 10 cm parallel distance) are supported by toroidally localized particle sources.
- Open Access
- 29 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (9) , 096032
Multi-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X
In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (f rad) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as f rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with f rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift (V d) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region (V d < 0) decreases the impurity content, while the upstream drift toward the LCFS (V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d/D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.
- 29 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (9) , 096032
Open AccessMulti-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X
In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (f rad) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as f rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with f rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift (V d) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region (V d < 0) decreases the impurity content, while the upstream drift toward the LCFS (V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d/D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.
- Open Access
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
The infrared imaging video bolometer at Wendelstein 7-X
The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (>500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (>1400), extended coverage, and increased spatial resolution.
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
Open AccessThe infrared imaging video bolometer at Wendelstein 7-X
The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (>500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (>1400), extended coverage, and increased spatial resolution.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Development of a 3-D tomography technique for Large Helical Device bolometry using EMC3-EIRENE grids
A three-dimensional (3-D) tomography technique is developed for the bolometry system in the Large Helical Device using the EMC3-EIRENE-defined mesh coordinates and the relative gradient smoothing extended to 3-D space. We utilize two types of bolometers, resistive bolometers and infra-red imaging video bolometers, to cover areas that are not visible with only one type of bolometer, the total channels of which are 1088. Although the resolution of the reconstructed solution rises to 59 400 voxels, we prove that the physically meaningful solution having little negative power is obtained by calculating geometry matrices with the tetrahedralization method and assessing the phantom emission and the synthetic data. Moreover, comparing solutions generated by conventional minimum Fisher regularization and 3-D extended relative gradient smoothing enables us to find that the latter provides a better solution.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Development of a 3-D tomography technique for Large Helical Device bolometry using EMC3-EIRENE grids
A three-dimensional (3-D) tomography technique is developed for the bolometry system in the Large Helical Device using the EMC3-EIRENE-defined mesh coordinates and the relative gradient smoothing extended to 3-D space. We utilize two types of bolometers, resistive bolometers and infra-red imaging video bolometers, to cover areas that are not visible with only one type of bolometer, the total channels of which are 1088. Although the resolution of the reconstructed solution rises to 59 400 voxels, we prove that the physically meaningful solution having little negative power is obtained by calculating geometry matrices with the tetrahedralization method and assessing the phantom emission and the synthetic data. Moreover, comparing solutions generated by conventional minimum Fisher regularization and 3-D extended relative gradient smoothing enables us to find that the latter provides a better solution.
- Open Access
- 30 November 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 41
Assessing the toroidal radiation distribution at Wendelstein 7-X by combining Gaussian Process Tomography and field line mapping
- 30 November 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 41
Open AccessAssessing the toroidal radiation distribution at Wendelstein 7-X by combining Gaussian Process Tomography and field line mapping
- Open Access
- 29 November 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (1) , 016035
Improved weighted sum estimation of total radiated power at W7-X
As magnetic confinement devices move toward higher fusion powers, moderating the heat load to the plasma-facing components becomes increasingly challenging. Efficient power dissipation can be achieved through control of the plasma radiation. However, defining a reliable proxy for the total radiated power is particularly challenging for non-axisymmetric devices such as stellarators. To address this problem, the radiated power can be estimated through a sum of the individual line-integrated bolometer measurements with weights properly calculated to account for the three-dimensional magnetic geometry. The present contribution aims to apply this weighted sum approach to Wendelstein 7-X (W7-X) and quantitatively validate it. First, we generate synthetic radiated power phantoms with characteristic W7-X radiation features to derive a set of optimized line-of-sight weights. Then, we test the weights on mock-ups and EMC3-EIRENE radiation patterns, including acquisition and analysis errors such as random noise fluctuations, camera misalignments, and field errors. Compared to other methods, the optimized weighted sum technique exhibited the best performance in all the presented synthetic test cases. When applied to experimental bolometer data, the optimized weights provided a proxy that is both reliable and real-time capable. Further validation is foreseen for the next experimental campaign.
- 29 November 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (1) , 016035
Open AccessImproved weighted sum estimation of total radiated power at W7-X
As magnetic confinement devices move toward higher fusion powers, moderating the heat load to the plasma-facing components becomes increasingly challenging. Efficient power dissipation can be achieved through control of the plasma radiation. However, defining a reliable proxy for the total radiated power is particularly challenging for non-axisymmetric devices such as stellarators. To address this problem, the radiated power can be estimated through a sum of the individual line-integrated bolometer measurements with weights properly calculated to account for the three-dimensional magnetic geometry. The present contribution aims to apply this weighted sum approach to Wendelstein 7-X (W7-X) and quantitatively validate it. First, we generate synthetic radiated power phantoms with characteristic W7-X radiation features to derive a set of optimized line-of-sight weights. Then, we test the weights on mock-ups and EMC3-EIRENE radiation patterns, including acquisition and analysis errors such as random noise fluctuations, camera misalignments, and field errors. Compared to other methods, the optimized weighted sum technique exhibited the best performance in all the presented synthetic test cases. When applied to experimental bolometer data, the optimized weights provided a proxy that is both reliable and real-time capable. Further validation is foreseen for the next experimental campaign.