Mohammad Reza Aflatoonian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammad Reza Aflatoonian has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Fariba Garkani Nejad
Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
1 shared publication - Hadi Beitollahi
Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
1 shared publication - Peyman Mohammadzadeh Jahani
School of Medicine, Bam University of Medical Sciences, Bam, Iran
1 shared publication - Reza Zaimbashi
Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
1 shared publication Somayeh Tajik
Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran
1 shared publication
Latest Publications
- Open Access
- 4 September 2024
- Published by International Association of Physical Chemists (IAPC) in ADMET and DMPK
- Vol. 12 (4) , 637-648
Determination of methotrexate using carbon paste electrode modified with ionic liquid/Ni-Co layered double hydroxide nanosheets as a voltammetric sensor
Background and purpose: Methotrexate (MTX) is a widely used anti-cancer drug, but its overuse can lead to significant side effects. Therefore, it is very vital to design simple and sensitive analytical methods for its determination. Experimental approach: In this work, an electrochemical sensor was prepared based on an ionic liquid (IL)/Ni-Co layered double hydroxide nanosheets (Ni-Co-LDH)-modified carbon paste electrode IL/Ni-Co-LDH/CPE. Cyclic voltammetry, differential pulse voltammetry, and chronoamperometry methods were applied to evaluate the performance of the designed sensor for MTX determination. Key results: The IL/Ni-Co-LDH/CPE sensor exhibits a linear relationship between the peak current of the differential pulse voltammetry and MTX concentrations in the linear dynamic range of 0.02 to 140.0 µM, with a detection limit of 0.006 µM. The IL/Ni-Co-LDH/CPE sensor exhibited relative standard deviation values between 1.7 to 3.7 % for recovery tests on real samples, indicating the precision of the method. Conclusion: The designed sensor with cost-effective and good performance could be valuable for therapeutic drug monitoring and clinical diagnostics.
- 4 September 2024
- Published by International Association of Physical Chemists (IAPC) in ADMET and DMPK
- Vol. 12 (4) , 637-648
Open AccessDetermination of methotrexate using carbon paste electrode modified with ionic liquid/Ni-Co layered double hydroxide nanosheets as a voltammetric sensor
Background and purpose: Methotrexate (MTX) is a widely used anti-cancer drug, but its overuse can lead to significant side effects. Therefore, it is very vital to design simple and sensitive analytical methods for its determination. Experimental approach: In this work, an electrochemical sensor was prepared based on an ionic liquid (IL)/Ni-Co layered double hydroxide nanosheets (Ni-Co-LDH)-modified carbon paste electrode IL/Ni-Co-LDH/CPE. Cyclic voltammetry, differential pulse voltammetry, and chronoamperometry methods were applied to evaluate the performance of the designed sensor for MTX determination. Key results: The IL/Ni-Co-LDH/CPE sensor exhibits a linear relationship between the peak current of the differential pulse voltammetry and MTX concentrations in the linear dynamic range of 0.02 to 140.0 µM, with a detection limit of 0.006 µM. The IL/Ni-Co-LDH/CPE sensor exhibited relative standard deviation values between 1.7 to 3.7 % for recovery tests on real samples, indicating the precision of the method. Conclusion: The designed sensor with cost-effective and good performance could be valuable for therapeutic drug monitoring and clinical diagnostics.