YTYu-Chong Tai

Yu-Chong Tai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yu-Chong Tai has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility and Structural Transformation of Electrodeposited Copper Foils for Graphene Synthesis by Plasma‐Enhanced Chemical Vapor Deposition: Implications for High‐Frequency Applications

    by Chen‐Hsuan Lu, Kuang‐Ming Shang, Shi‐Ri Lee, Jheng‐Ying Li, Patricia T.C. Lee, Chyi‐Ming Leu, Yu‐Chong Tai, Nai‐Chang Yeh

    Large‐area graphene is typically synthesized on rolled‐annealed copper foils, which require transferring to other substrates for applications. This study examines large‐area graphene growth on electrodeposited (ED) copper foils—used in lithium‐ion batteries and printed circuit boards—via plasma‐enhanced chemical vapor deposition (PECVD). It reveals that, for a set plasma power, a minimum growth time ensures full graphene coverage, leading to monolayer and then multilayer graphene, showing PECVD growth on ED copper is not self‐limited. The process also beneficially modifies the ED copper substrate, like removing the surface zinc layer and changing copper grain size and orientation, thus improving graphene growth. Additionally, the study includes high‐frequency scattering parameter (S‐parameter) measurements in a coplanar waveguide (CPW) system. This involves graphene on a sapphire substrate with a silver electrode. The S‐parameter data indicate that the CPW with graphene shows reduced insertion losses in high‐frequency circuits compared to those without graphene. This underscores graphene's role in reducing insertion losses between metallic and dielectric layers in high‐frequency settings, offering valuable insights for industrial and technological applications.


  • Open Access

    Highly controllable and reliable ultra-thin Parylene deposition

    by Yaoping Liu, Dongyang Kang, Wangzhi Dai, Haida Li, Wei Wang, Yu-Chong Tai


  • Parylene-oil-encapsulated low-drift implantable pressure sensors

    by Aubrey Shapero, Yu-Chong Tai

    This paper demonstrates a parylene-oil-encapsulated packaging technology that applies to commercial pressure sensors to enable intraocular pressure sensing with minimal drift. Commercial digital-output barometers are chosen to be packaged first with 100,000 cSt silicone oil and then sub-micron thick parylene within the volume of the original housing. It is newly found that parylene type and oil viscosity can decide the sign and magnitude of the intrinsic stress in parylene. Additionally, the effect of deposited thickness and temperature on film stress is studied through induced pressure offset. When properly designed, parylene-oil-encapsulated pressure sensors maintain <;0.3% sensitivity drift and <;1 to 2 mmHg offset drift for over 50 to 106+ days in 77 °C saline, equivalent to 25 to 53+ months at 37 °C [1]. This new compact packaging method is promising for converting air-operated commercial sensors to be “implantable” with nearly original sensitivity and minimal offset and drift.


  • Reliable deposition of ultra-thin parylene

    by Wei Wang, Dongyang Kang, Wangzhi Dai, Yu-Chong Tai

    This paper reports a novel and reliable process to prepare ultra-thin parylene film based on a principle combining both molecular effusion and diffusion. For the first time, a technique for the deposition of parylene film thinner than 20 nm in a highly controllable and repeatable way is developed. Parylene films with various thicknesses could also be prepared in a single deposition run by using this method. This technique holds promising potentials in extensive applications, such as protection/dielectric layer for needle electrodes and flexible electronics, semi-permeable membrane, and other polymer engineering.


  • A fully intraocular 0.0169mm2/pixel 512-channel self-calibrating epiretinal prosthesis in 65nm CMOS

    by Manuel Monge, Mayank Raj, Meisam Honarvar-Nazari, Han-Chieh Chang, Yu Zhao, James Weiland, Mark Humayun, Yu-Chong Tai, Azita Emami-Neyestanak

    Since their conception and success in human trials, the flexibility and spatial resolution of retinal prostheses have been of major interest. Clinical studies have revealed that hundreds of channels are needed to restore functional visual perception, and more sophisticated waveforms present advantages over biphasic pulses. Initial designs targeted stimulation current levels up to 1mA to ensure functionality. For such designs, an output compliance of >10V was required, and HV technologies were used at the expense of area and power consumption. Human clinical trials have recently shown that implanted electrodes present a stimulus threshold as low as 50μA. In addition, advances in implant technology promise close placement of electrode array and retinal tissue, which can further decrease the required current. Thus, highly scaled LV technologies can provide alternative means to reduce area and power, and to support hundreds of flexible independent channels for fully intraocular implants. In this paper, a self-calibrating 512-channel epiretinal prosthesis in 65nm CMOS is presented. It features dual-band telemetry for power and data, clock recovery, a 2-step calibration technique to match biphasic stimulation currents, and an independent arbitrary output waveform per channel. The implant integrates coils (power and data), IC, external capacitors and electrode array using a biocompatible parylene substrate, providing a fully intraocular solution.


  • High yield packaging for high-density multi-channel chip integration on flexible parylene substrate

    by Jay Han-Chieh Chang, Dongyang Kang, Yu-Chong Tai

    This paper reports a new chip packaging technique for the assembly of retinal prosthesis device. Here, a photoresist is used as glue to attach a chip to the targeted parylene-C substrate so that 94% of the chip area is used as attachment to prevent delamination. As a validation, chips with 268 connections were used to assess the connection yield. The results show that this new technique, combined with an additional parylene-C coating, provide a high connection yield (>;90%) and is a promising method for high-lead-count implant devices.


  • Open Access

    Mass flowmeter using a multi-sensor chip

    by Yong Xu, Chen-Wei Chiu, Fukang Jiang, Qiao Lin, Yu-Chong Tai

    We report here a novel mass flowmeter using a multisensor chip that includes a 1-D array of pressure, temperature and shear stress sensors. This shear stress sensor based flowmeter is capable of high sensitivity and wide measurement range. Our study also shows that the mass flowmeter using shear-stress sensors produces better resolution than that from pressure sensors in the laminar flow regime. Extensive tests have been carried out to evaluate the effects of overheat ratio, channel height and gas properties. We also find the V/sup 2//spl prop//spl tau//sup 1/3/ law for conventional hot film sensors does not hold for our micromachined shear stress sensor.


  • Open Access

    A practical thermopneumatic valve

    by C. Grosjean, Xing Yang, Yu-Chong Tai

    Previously, we reported a thermopneumatic silicone rubber membrane valve [1997]. This valve combined thermopneumatic actuation with a low modulus silicone rubber membrane. However, the leakage of the working fluid through the membrane rendered the valve unusable in a day or two. Here, we present extensive optimization and characterization of a redesigned valve structure. This new design has a suspended membrane heater optimized for low power consumption, a composite silicone rubber on Parylene membrane that exhibits low permeability and modulus, and a novel valve seat designed to improve sealing in the presence of particles. The valve has been extensively characterized with respect to power consumption vs. flow rate and transient response. Very low power consumption has been demonstrated. For example, less than 40 mW is required to switch a one slpm nitrogen flow at 33 psi. Water requires close to 100 mW due to the cooling effect of the liquid. The previously reported valve required more than 280 mW to switch a similar air flow.