Jie Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jie Yu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Yicheng Ni
National Platform for Medical Engineering & Education Integration (NMEE) Zhongda Hospital Southeast University Nanjing China
2 shared publications - Feng Chen
Department of Thoracic Surgery, Tianjin Chest Hospital & Tianjin University Affiliated Chest Hospital , No. 261 Taierzhuang South Road, Jinnan District, Tianjin 300222
1 shared publication - Gang Huang
Shanghai Key Laboratory of Molecular Imaging, Pudong Gongli Hospital, Shanghai University of Medicine and Health Sciences, Shanghai, China
1 shared publication Guy Marchal
University Hospitals, K.U. Leuven
1 shared publication- Hao Zhang
Xi’an Jiaotong University
1 shared publication Marlein Miranda Cona
Theragnostic Laboratory Department of Imaging and Pathology, Biomedical Sciences Group, KU Leuven Herestraat 49 3000 Leuven Belgium
1 shared publication
Latest Publications
- RetractedOpen Access
- 6 September 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (9) , e0303613
RETRACTED: Evaluation of influencing factors of China university teaching quality based on fuzzy logic and deep learning technology
Nowadays, colleges and universities focus on the assessment model for considering educational offers, suitable environments, and circumstances for students’ growth, as well as the influence of Teaching Quality (TQ) and the applicability of the skills promoted by teaching to life. Teaching excellence is an important evaluation metric at the university level, but it is challenging to determine it accurately due to its wide range of influencing factors. Fuzzy and Deep Learning (DL) approaches must be could to build an assessment model that can precisely measure the teaching qualities to enhance accuracy. Combining fuzzy logic and DL can provide a powerful approach for assessing the influencing factors of college and university teaching effects by implementing the Sequential Intuitionistic Fuzzy (SIF) assisted Long Short-Term Memory (LSTM) model proposed. Sequential Intuitionistic Fuzzy (SIF) can be used sets to assess factors that affect teaching quality to enhance teaching methods and raise the standard of education. LSTM model to create a predictive model that can pinpoint the primary factors that influence teaching quality and forecast outcomes in the future using those influencing factors for academic growth. The enhancement of the SIF-LSTM model for assessing the influencing factors of teaching quality is proved by the accuracy of 98.4%, Mean Square Error (MSE) of 0.028%, Tucker Lewis Index (TLI) measure for all influencing factors and entropy measure of non-membership and membership degree correlation of factors related to quality in teaching by various dimensional measures. The effectiveness of the proposed model is validated by implementing data sources with a set of 60+ teachers’ and students’ open-ended questionnaire surveys from a university.
- 6 September 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (9) , e0303613
RetractedOpen AccessRETRACTED: Evaluation of influencing factors of China university teaching quality based on fuzzy logic and deep learning technology
Nowadays, colleges and universities focus on the assessment model for considering educational offers, suitable environments, and circumstances for students’ growth, as well as the influence of Teaching Quality (TQ) and the applicability of the skills promoted by teaching to life. Teaching excellence is an important evaluation metric at the university level, but it is challenging to determine it accurately due to its wide range of influencing factors. Fuzzy and Deep Learning (DL) approaches must be could to build an assessment model that can precisely measure the teaching qualities to enhance accuracy. Combining fuzzy logic and DL can provide a powerful approach for assessing the influencing factors of college and university teaching effects by implementing the Sequential Intuitionistic Fuzzy (SIF) assisted Long Short-Term Memory (LSTM) model proposed. Sequential Intuitionistic Fuzzy (SIF) can be used sets to assess factors that affect teaching quality to enhance teaching methods and raise the standard of education. LSTM model to create a predictive model that can pinpoint the primary factors that influence teaching quality and forecast outcomes in the future using those influencing factors for academic growth. The enhancement of the SIF-LSTM model for assessing the influencing factors of teaching quality is proved by the accuracy of 98.4%, Mean Square Error (MSE) of 0.028%, Tucker Lewis Index (TLI) measure for all influencing factors and entropy measure of non-membership and membership degree correlation of factors related to quality in teaching by various dimensional measures. The effectiveness of the proposed model is validated by implementing data sources with a set of 60+ teachers’ and students’ open-ended questionnaire surveys from a university.
- Open Access
- 15 April 2015
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 10 (5) , 379-387
Three‐dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners
The purpose of this work was to visualize the pancreas in post‐mortem rats with local contrast medium infusion by three‐dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo‐EB containing optimized concentrations of Gd‐DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post‐contrast imaging with 3.0 T MRI and 128‐slice CT scanners. Images were post‐processed with the MeVisLab software package. MRI findings were co‐registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo‐EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm3 after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.
- 15 April 2015
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 10 (5) , 379-387
Open AccessThree‐dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners
The purpose of this work was to visualize the pancreas in post‐mortem rats with local contrast medium infusion by three‐dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo‐EB containing optimized concentrations of Gd‐DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post‐contrast imaging with 3.0 T MRI and 128‐slice CT scanners. Images were post‐processed with the MeVisLab software package. MRI findings were co‐registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo‐EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm3 after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.
- 1 January 2002
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 56 (2) , 119-126
Evaluation of Radiofrequency Ablation as an Alternative for the Treatment of Brain Tumor in Rabbits
Radiofrequency ablation (RFA) has emerged recently as a promising therapy for extracranial malignancies. This experiment was conducted to explore the potential of RFA for the treatment of brain tumor...
- 1 January 2002
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 56 (2) , 119-126
Evaluation of Radiofrequency Ablation as an Alternative for the Treatment of Brain Tumor in Rabbits
Radiofrequency ablation (RFA) has emerged recently as a promising therapy for extracranial malignancies. This experiment was conducted to explore the potential of RFA for the treatment of brain tumor...