Canan Ekinci Dogan
Canan Ekinci Dogan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Nur Cebi
Department of Food Engineering, Faculty of Chemical and Metallurgical Engineering, Yildiz Technical University
3 shared publications Ayten Ekin Mese
İzmir Institute of Technology, Faculty of Science, Chemistry Department, 35430 İzmir, Turkey
1 shared publication- Durmuş Özdemir
İZMİR YÜKSEK TEKNOLOJİ ENSTİTÜSÜ, FEN FAKÜLTESİ
1 shared publication Elmas Oktem Olgun
TUBITAK MRC Food Institute, 41470 Gebze, Kocaeli, Turkey
1 shared publicationMuhammet Arıcı
Yıldız Technical University, Chemical and Metallurgical Engineering Faculty, Food Engineering Department, 34210 İstanbul, Turkey
1 shared publication- Nur Cebi
Yıldız Technical University, Chemical and Metallurgical Engineering Faculty, Food Engineering Department, 34210 İstanbul, Turkey
1 shared publication
Latest Publications
- Open Access
- 3 January 2020
- Published by Codon Publications in Quality Assurance and Safety of Crops & Foods
- Vol. 12 (1) , 1-10
Evaluation of Raman microscopy for the detection of additional monosodium glutamate in dry soup mix
This article presents Raman chemical mapping application for the detection of adulterant monosodium glutamate (MSG) in dry soup mix. MSG may cause various damages to the health of people. Therefore, there are legal regulations for this compound both in Turkish Food Codex and European Union Directives. Most of the times, the main problem is that MSG is added into dry soup products without declaration on the label. Food control mechanisms need effective and real-time monitoring methods to check the reliability of the product labels in order to maintain food safety and alleviate public doubts. In this study, MSG was added into dry soup mix at a concentration (w/w) of 0.1, 0.2, 0.4 and 0.6% and chemical maps were obtained using multivariate data analysis techniques such as direct classical least squares (DCLS) component analysis. MSG was successfully detected and spectral and spatial distribution of the MSG within the commercial and laboratory-prepared dry soup samples was accomplished, with a detection limit of 0.1%. The results obtained were confirmed by a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique.
- 3 January 2020
- Published by Codon Publications in Quality Assurance and Safety of Crops & Foods
- Vol. 12 (1) , 1-10
Open AccessEvaluation of Raman microscopy for the detection of additional monosodium glutamate in dry soup mix
This article presents Raman chemical mapping application for the detection of adulterant monosodium glutamate (MSG) in dry soup mix. MSG may cause various damages to the health of people. Therefore, there are legal regulations for this compound both in Turkish Food Codex and European Union Directives. Most of the times, the main problem is that MSG is added into dry soup products without declaration on the label. Food control mechanisms need effective and real-time monitoring methods to check the reliability of the product labels in order to maintain food safety and alleviate public doubts. In this study, MSG was added into dry soup mix at a concentration (w/w) of 0.1, 0.2, 0.4 and 0.6% and chemical maps were obtained using multivariate data analysis techniques such as direct classical least squares (DCLS) component analysis. MSG was successfully detected and spectral and spatial distribution of the MSG within the commercial and laboratory-prepared dry soup samples was accomplished, with a detection limit of 0.1%. The results obtained were confirmed by a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique.
- 7 March 2019
- Published by Wiley in Packaging Technology and Science
- Vol. 32 (5) , 239-246
Investigation of antimony, cobalt, and acetaldehyde migration into the drinking water in Turkey
Polyethylene terephthalate (PET) is a widely used material for the packaging of drinking water. The development of this research arises from the demand of a popular Turkish drinking water company, which has reported odour problems in their PET bottled products. Acetaldehyde, cobalt, and antimony contents were determined in bottled water of different volumes (0.5, 1.5, and 5 L), PET bottles, plastic blue closures, and preform material by gas chromatography mass spectrometry (GC‐MS) and inductively coupled plasma mass spectrometry (ICP‐MS). Antimony, cobalt, and acetaldehyde migration into the drinking water (PET bottled) was tracked for every 2 months through a year. Migration of these compounds rose with increased storage time at 20°C. The highest amounts of migrated compounds were observed in 0.5 L (smallest) of PET bottles. All migration results were found to be under the migration limit at the end of storage period. In addition to these findings, nonintentionally added substances (NIASs) analyses were performed by headspace (HS)/GC‐MS. Odour‐active compounds were identified using the library database. Off‐odours in the drinking water were due to the migration of various compounds such as acetaldehyde and other NIASs from PET bottle into the drinking water. In addition, acetaldehyde amounts were ranged from 0 to 140 μg/L in all drinking waters, and some acetaldehyde values were above the taste threshold of 15 μg/L.
- 7 March 2019
- Published by Wiley in Packaging Technology and Science
- Vol. 32 (5) , 239-246
Investigation of antimony, cobalt, and acetaldehyde migration into the drinking water in Turkey
Polyethylene terephthalate (PET) is a widely used material for the packaging of drinking water. The development of this research arises from the demand of a popular Turkish drinking water company, which has reported odour problems in their PET bottled products. Acetaldehyde, cobalt, and antimony contents were determined in bottled water of different volumes (0.5, 1.5, and 5 L), PET bottles, plastic blue closures, and preform material by gas chromatography mass spectrometry (GC‐MS) and inductively coupled plasma mass spectrometry (ICP‐MS). Antimony, cobalt, and acetaldehyde migration into the drinking water (PET bottled) was tracked for every 2 months through a year. Migration of these compounds rose with increased storage time at 20°C. The highest amounts of migrated compounds were observed in 0.5 L (smallest) of PET bottles. All migration results were found to be under the migration limit at the end of storage period. In addition to these findings, nonintentionally added substances (NIASs) analyses were performed by headspace (HS)/GC‐MS. Odour‐active compounds were identified using the library database. Off‐odours in the drinking water were due to the migration of various compounds such as acetaldehyde and other NIASs from PET bottle into the drinking water. In addition, acetaldehyde amounts were ranged from 0 to 140 μg/L in all drinking waters, and some acetaldehyde values were above the taste threshold of 15 μg/L.
- 1 March 2019
- Published by Elsevier in Food Chemistry
- Vol. 277, 373-381
A rapid ATR-FTIR spectroscopic method for classification of gelatin gummy candies in relation to the gelatin source
- 1 March 2019
- Published by Elsevier in Food Chemistry
- Vol. 277, 373-381
A rapid ATR-FTIR spectroscopic method for classification of gelatin gummy candies in relation to the gelatin source
- 1 May 2018
- Published by Elsevier in Food Chemistry
- Vol. 248, 8-13
A survey of free glutamic acid in foods using a robust LC–MS/MS method
- 1 May 2018
- Published by Elsevier in Food Chemistry
- Vol. 248, 8-13
A survey of free glutamic acid in foods using a robust LC–MS/MS method
- 10 June 2015
- Published by Taylor & Francis in Food Additives & Contaminants: Part B
- Vol. 8 (3) , 221-226
Formaldehyde migration in aqueous extracts from paper and cardboard food packaging materials in Turkey
Migration of formaldehyde to aqueous extracts from paper and cardboard food packaging materials was determined by an ultraviolet visible-spectrophotometric method at 410 nm. Intraday and interday precision of the method, expressed as coefficient of variation, varied between 1.5 to 4.4% and 7 to 8.8%, respectively. The limit of quantification was 0.28 mg kg−1 for formaldehyde in aqueous extracts. The recovery of the method was over 90% for two different concentration levels in aqueous extracts. The method was applied to the migration of formaldehyde to aqueous extracts from 31 different paper and cardboard materials collected from the packaging sector, intended for food contact, such as tea filters, hot water filters, paper pouches and folding boxes. The results were between limit of detection 0.23 mg/kg and 40 mg kg−1 and were evaluated according to the relevant directives.
- 10 June 2015
- Published by Taylor & Francis in Food Additives & Contaminants: Part B
- Vol. 8 (3) , 221-226
Formaldehyde migration in aqueous extracts from paper and cardboard food packaging materials in Turkey
Migration of formaldehyde to aqueous extracts from paper and cardboard food packaging materials was determined by an ultraviolet visible-spectrophotometric method at 410 nm. Intraday and interday precision of the method, expressed as coefficient of variation, varied between 1.5 to 4.4% and 7 to 8.8%, respectively. The limit of quantification was 0.28 mg kg−1 for formaldehyde in aqueous extracts. The recovery of the method was over 90% for two different concentration levels in aqueous extracts. The method was applied to the migration of formaldehyde to aqueous extracts from 31 different paper and cardboard materials collected from the packaging sector, intended for food contact, such as tea filters, hot water filters, paper pouches and folding boxes. The results were between limit of detection 0.23 mg/kg and 40 mg kg−1 and were evaluated according to the relevant directives.