HMHide Matsumoto

Hide Matsumoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hide Matsumoto has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Relationship Between Anterior–Posterior Plantar Reaction Force Distribution and Gait Speed in Post-Stroke Patients

    by Daiki Naito, Yusuke Sekiguchi, Keita Honda, Midori Miyagi, Takeshi Yamaguchi, Toshiaki Nishi, Yoshihiro Sasaki, Jun-Ichi Hayasaka, Hide Matsumoto, Yuzuki Nakai, et al.

    Background: Gait speed is an important indicator of walking ability in post-stroke patients. Although gait speed is associated with anterior–posterior reaction force (AP RF), how AP RF is distributed across the plantar surface and whether this distribution is associated with gait speed remain unclear. Methods: Fifteen post-stroke patients and 18 healthy controls were included. AP RF was measured during walking using a sensor shoe system equipped with four triaxial force sensors located at the heel, first metatarsal (MT1), fifth metatarsal (MT5), and toe regions. AP RF distribution was quantified as the relative contribution of each plantar region and compared among the paretic, non-paretic, and control sides across the stance phase using linear mixed-effects models. Associations between AP RF distribution and gait speed were examined using Spearman’s rank correlation coefficients, with p-values adjusted for multiple testing using the Benjamini–Hochberg false discovery rate procedure. Results: Significant group × stance phase interactions were observed for the relative contributions of MT1 and MT5. After correction for multiple comparisons, the MT1 contribution at 81–90% of the stance phase was lower on both the paretic and non-paretic sides than on the control side, whereas the MT5 contribution at 1–10% was higher on both sides than on the control side. Total AP RF was also lower on the paretic and/or non-paretic sides than on the control side during several stance phases. On the non-paretic side, the MT5 contribution at 1–10% was negatively correlated with gait speed (rs = −0.66, BH-FDR adjusted p = 0.04). Conclusions: Post-stroke patients showed altered AP RF distribution during the early and late stance phases compared with healthy controls. Greater MT5 contribution on the non-paretic side during early stance was associated with slower gait speed, suggesting that AP RF distribution may provide additional information for characterizing gait impairment after stroke beyond total AP RF.

  • Open Access

    Characteristics of Ground Reaction Force Variability During Walking in Post-Stroke Patients

    by Daiki Naito, Yusuke Sekiguchi, Keita Honda, Midori Miyagi, Takeshi Yamaguchi, Toshiaki Nishi, Hide Matsumoto, Yuzuki Nakai, Yoshihiro Sasaki, Jun-Ichi Hayasaka, et al.

    Gait impairment in post-stroke patients increases the risk of falls, but the role of ground reaction force variability (GRF variability) in controlling gait stability remains unclear. The objectives of this study were (1) to clarify the differences in GRF variability during walking between post-stroke patients and age-matched controls and (2) to identify the differences in GRF variability between post-stroke patient fallers and non-fallers. Sixteen post-stroke patients (age: 72.19 ± 8.54, six female, four fallers: age: 71.75 ± 11.32, twelve non-fallers: age: 72.33 ± 8.03) and nineteen age-matched controls (age: 68.63 ± 5.73, nine female) participated. GRF variability was measured using shoe sensors during walking. After adjusting for walking speed, the anterior–posterior (AP) GRF variability on the paretic side in the 91–100% stance phase was significantly lower in the post-stroke patients (F = 3.721, p = 0.038). This phase’s AP GRF variability was not correlated with Berg Balance Scale scores. Furthermore, the faller group in stroke patients showed the AP GRF variability on the paretic side was lower in the 41–50% (W = 17, p = 0.045), 51–60% (W = 16, p = 0.045), 61–70% (W = 16, p = 0.045), and 91–100% (W = 23, p = 0.045) sub-stance phases. After adjusting for sex and orthosis, the sensitivity analysis showed no significant intergroup difference. This suggested an adaptive control mechanism for maintaining gait and avoiding falls in post-stroke patients.


  • Open Access

    Characteristics of Ground Reaction Force During Walking in Post-Stroke Patients

    by Daiki Naito, Yusuke Sekiguchi, Keita Honda, Midori Miyagi, Takeshi Yamaguchi, Toshiaki Nishi, Hide Matsumoto, Yzuki Nakai, Yoshihiro Sasaki, Jun-Ici Hayasaka, et al.

    Gait impairment in post-stroke patients increases the risk of falls, but the role of g round r eaction f orce variability (GRF variability) in controlling gait stability remains unclear. This study aimed to characterize GRF variability during walking in post-stroke patients. 16 post-stroke patients (age: 72.19 ± 8.54, 6 female, 4 fallers: age: 71.75 ± 11.32, 12 non-fallers: age: 72.33 ± 8.03) and 19 age-matched healthy controls (age: 68.63 ± 5.73, 9 female) participated. GRF variability was measured using shoe sensors during walking. After adjusting for walking speed, the a nterior- p osterior (AP) GRF variability on the paretic side in the 91 – 100% stance phase was significantly lower in the post-stroke patients (p = 0.038). This phase’s AP GRF variability was not correlated with Berg Balance Scale scores. Furthermore, the faller group in stroke patients showed the AP GRF variability on the paretic side was lower in the 11 – 20% (p = 0.045), 41 – 50% to 61 – 70% stance phases (p = 0.045, p = 0.034, p = 0.034) after adjusting for sex and orthosis. This suggests that AP GRF variability on the paretic side is involved in the maintenance of walking stability in post-stroke patients.


  • Open Access

    Comparing the Ground Reaction Forces, Toe Clearances, and Stride Lengths of Young and Older Adults Using a Novel Shoe Sensor System

    by Hide Matsumoto, Masaki Tomosada, Toshiaki Nishi, Yoshihiro Sasaki, Ryota Sakurai, Takeshi Yamaguchi

    In this study, we developed a lightweight shoe sensor system equipped with four high-capacity, compact triaxial force sensors and an inertial measurement unit. Remarkably, this system enabled measurements of localized three-directional ground reaction forces (GRFs) at each sensor position (heel, first and fifth metatarsal heads, and toe) and estimations of stride length and toe clearance during walking. Compared to conventional optical motion analysis systems, the developed sensor system provided relatively accurate results for stride length and minimum toe clearance. To test the performance of the system, 15 older and 8 young adults were instructed to walk along a straight line while wearing the system. The results reveal that compared to the young adults, older adults exhibited lower localized GRF contributions from the heel and greater localized GRF contribution from the toe and fifth metatarsal locations. Furthermore, the older adults exhibited greater variability in their stride length and smaller toe clearance with greater variability compared to the young adults. These results underscore the effectiveness of the proposed gait analysis system in distinguishing the gait characteristics of young and older adults, potentially replacing traditional motion capture systems and force plates in gait analysis.


  • Open Access

    Comparing the Ground Reaction Forces, Toe Clearances, and Stride Lengths of Young and Older Adults Using a Novel Shoe Sensor System

    by Hide Matsumoto, Masaki Tomosada, Toshiaki Nishi, Yoshinori Sasaki, Ryota Sakurai, Takeshi Yamaguchi

    In this study, we developed a lightweight shoe sensor system equipped with four high-capacity, compact triaxial force sensors and an inertial measurement unit. Remarkably, this system enabled measurements of localized three-directional ground reaction forces (GRFs) at each sensor position (heel, first and fifth metatarsal heads, and toe) and estimations of stride length and toe clearance during walking. Compared to conventional optical motion analysis systems, the developed sensor system provided relatively accurate results for stride length and minimum toe clearance. To test the performance of the system, 15 older and eight young adults were instructed to walk along a straight-line while wearing the system. The results revealed that compared to the young adults, older adults exhibited lower localized GRF contributions from the heel and greater localized GRF contribution from the toe and fifth metatarsal locations. Furthermore, the older adults exhibited greater variability in their stride length and smaller toe clearance with greater variability compared to the young adults. These results underscore the effectiveness of the proposed gait analysis system in distinguishing the gait characteristics of young and older adults, potentially replacing traditional motion capture systems and force plates in gait analysis.