CMCristian Morente-Lorenzo

Cristian Morente-Lorenzo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cristian Morente-Lorenzo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Two Handheld Retinograph Devices Evaluated by Ophthalmologists and an Artificial Intelligence Algorithm

    by Pedro Romero-Aroca, Benilde Fontoba-Poveda, Eugeni Garcia-Curto, Aida Valls, Julián Cristiano, Monica Llagostera-Serra, Cristian Morente-Lorenzo, Isabel Mendez-Marín, Marc Baget-Bernaldiz

    Background/Objectives: Telemedicine in diabetic retinopathy (RD) screening is effective but does not reach the entire diabetes population. The use of portable cameras and artificial intelligence (AI) can help in screening diabetes. Methods: We evaluated the ability of two handheld cameras, one based on a smartphone and the other on a smartscope, to obtain images for comparison with OCT. Evaluation was carried out in two stages: the first by two retina specialists and the second using an artificial intelligence algorithm that we developed. Results: The retina specialists reported that the smartphone images required mydriasis in all cases, compared to 73.05% of the smartscope images and 71.11% of the OCT images. Images were ungradable in 27.98% of the retinographs with the smartphone and in 7.98% with the smartscope. The detection of any DR using the AI algorithm showed that the smartphone obtained lower recall values (0.89) and F1 scores (0.89) than the smartscope, with 0.99. Low results were also obtained using the smartphone to detect mild DR (146 retinographs), compared to using the smartscope (218 retinographs). Conclusions: we consider that the use of handheld devices together with AI algorithms for reading retinographs can be useful for DR screening, although the ease of image acquisition through small pupils with these devices needs to be improved.


  • Open Access

    Artificial Intelligence-Based Screening System for Diabetic Retinopathy in Primary Care

    by Marc Baget-Bernaldiz, Benilde Fontoba-Poveda, Pedro Romero-Aroca, Raul Navarro-Gil, Adriana Hernando-Comerma, Angel Bautista-Perez, Monica Llagostera-Serra, Cristian Morente-Lorenzo, Montse Vizcarro, Alejandra Mira-Puerto

    Background: This study aimed to test an artificial intelligence-based reading system (AIRS) capable of reading retinographies of type 2 diabetic (T2DM) patients and a predictive algorithm (DRPA) that predicts the risk of each patient with T2DM of developing diabetic retinopathy (DR). Methods: We tested the ability of the AIRS to read and classify 15,297 retinal photographs from our database of diabetics and 1200 retinal images taken with Messidor-2 into the different DR categories. We tested the DRPA in a sample of 40,129 T2DM patients. The results obtained by the AIRS and the DRPA were then compared with those provided by four retina specialists regarding sensitivity (S), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), accuracy (ACC), and area under the curve (AUC). Results: The results of testing the AIRS for identifying referral DR (RDR) in our database were ACC = 98.6, S = 96.7, SP = 99.8, PPV = 99.0, NPV = 98.0, and AUC = 0.958, and in Messidor-2 were ACC = 96.78%, S = 94.64%, SP = 99.14%, PPV = 90.54%, NPV = 99.53%, and AUC = 0.918. The results of our DRPA when predicting the presence of any type of DR were ACC = 0.97, S = 0.89, SP = 0.98, PPV = 0.79, NPV = 0.98, and AUC = 0.92. Conclusions: The AIRS performed well when reading and classifying the retinographies of T2DM patients with RDR. The DRPA performed well in predicting the absence of DR based on some clinical variables.