David Ou-Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Ou-Yang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Aaron B. Epperson
Orthopedics Department, University of Colorado Anschutz Medical Campus, Aurora, Colorado
1 shared publication- Brian P. Gorman
Colorado School of Mines
1 shared publication - Cheryl L. Ackert-Bicknell
Colorado Program for Musculoskeletal Research, Department of Orthopedics, University of Colorado School of Medicine, Aurora, CO
1 shared publication - Christopher J. Kleck
Department of Orthopedic Surgery, University of Colorado School of Medicine, Aurora, CO, USA
1 shared publication - Evalina L. Burger
University of Colorado, Anschutz. School of Medicine, Orthopedics, 13001 East 17th Avenue, Aurora, CO, United States of America, 80045
1 shared publication Evan Amnidown
Colorado School of Mines, Department of Metallugical and Materials Engineering, 1500 Illinois St., Golden, CO 80401
1 shared publication
Latest Publications
- Open Access
Microbial Influenced Corrosion: A Novel Initiator of In Vivo Spine Rod Fracture
Spine rod catastrophic failure/rod fracture after implantation is estimated to occur in ∼10% of all cases worldwide with this rate remaining consistent for more than 20 years. To accommodate the spine mechanical environment, metal alloys such as austenitic stainless steels, cobalt–chromium–molybdenum alloys, and α/β type titanium alloys such are used as they have a high resistance to fatigue failure. The work presented herein addresses the gap in understanding about what happens in a laboratory environment versus what is happening in human patients that results in metal leaching into tissues as well as a shortened lifespan of a spine rod in a patient population that is not capable of breaking these spine rods from purely mechanical means. Eighty-five (N=85) patients (51 female – 62.9 ± 13.5 years old, 34 male - 62.7 ± 10.9 years old) who had spine revision surgery due to patient mechanical issues, such as loss of sagittal or coronal balance, pain, pedicle screw loosening, hardware associated infection were included in this study. All explanted rods had optical indications of surface modification that were not the result of mechanical damage, e.g. gouges, scratches, notches. The presence of Ti6Al4V rods increases the presence of local tissue concentrations of elemental Ti (190.98 ± 207.84 μg/g (ppm)) in all patients over the amount that would normally be present in patients who never had any titanium based orthopedic device implants (spinous muscle, 13.12 ± 11.43 μg/g). PQS, HHQ, and NHQ ToF-SIMS molecular signals were found co-located to corrosion pits as well with AHLs and palmitic acids indicating microbial presence and metabolism in all patients. This suggests that MIC can cause in vivo pitting corrosion resulting on rod failure.
Open AccessMicrobial Influenced Corrosion: A Novel Initiator of In Vivo Spine Rod Fracture
Spine rod catastrophic failure/rod fracture after implantation is estimated to occur in ∼10% of all cases worldwide with this rate remaining consistent for more than 20 years. To accommodate the spine mechanical environment, metal alloys such as austenitic stainless steels, cobalt–chromium–molybdenum alloys, and α/β type titanium alloys such are used as they have a high resistance to fatigue failure. The work presented herein addresses the gap in understanding about what happens in a laboratory environment versus what is happening in human patients that results in metal leaching into tissues as well as a shortened lifespan of a spine rod in a patient population that is not capable of breaking these spine rods from purely mechanical means. Eighty-five (N=85) patients (51 female – 62.9 ± 13.5 years old, 34 male - 62.7 ± 10.9 years old) who had spine revision surgery due to patient mechanical issues, such as loss of sagittal or coronal balance, pain, pedicle screw loosening, hardware associated infection were included in this study. All explanted rods had optical indications of surface modification that were not the result of mechanical damage, e.g. gouges, scratches, notches. The presence of Ti6Al4V rods increases the presence of local tissue concentrations of elemental Ti (190.98 ± 207.84 μg/g (ppm)) in all patients over the amount that would normally be present in patients who never had any titanium based orthopedic device implants (spinous muscle, 13.12 ± 11.43 μg/g). PQS, HHQ, and NHQ ToF-SIMS molecular signals were found co-located to corrosion pits as well with AHLs and palmitic acids indicating microbial presence and metabolism in all patients. This suggests that MIC can cause in vivo pitting corrosion resulting on rod failure.
- 1 September 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (9)
Extended Postoperative Antibiotic Prophylaxis Is Associated with No Clinical Value and Higher Projected Cost Following Adult Spinal Surgery
» We aimed to determine the cost-effectiveness of different protocols of extended postoperative antibiotic prophylaxis (E-PAP) following adult spinal surgery. » Both stratified (randomized controlled trials only) and nonstratified (all studies) analyses demonstrated that E-PAP has no significant value in reducing the rate of surgical site infection (SSI), deep SSI, or superficial SSI. » Notably, the E-PAP protocols were associated with a significant increase in the length of hospital stay, resulting in an additional expenditure of $244.4 per episode for the E-PAP 72 hours protocol compared with PAP 24 hours and $309.8 per episode for the E-PAP >48 hours protocol compared with PAP <48 hours. » E-PAP does not demonstrate any significant reduction in the rate of SSIs following spine surgery. However, these extended protocols were significantly associated with an increase in the length of hospital stay and higher overall projected costs. Level of Evidence: Level I. See Instructions for Authors for a complete description of levels of evidence.
- 1 September 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (9)
Extended Postoperative Antibiotic Prophylaxis Is Associated with No Clinical Value and Higher Projected Cost Following Adult Spinal Surgery
» We aimed to determine the cost-effectiveness of different protocols of extended postoperative antibiotic prophylaxis (E-PAP) following adult spinal surgery. » Both stratified (randomized controlled trials only) and nonstratified (all studies) analyses demonstrated that E-PAP has no significant value in reducing the rate of surgical site infection (SSI), deep SSI, or superficial SSI. » Notably, the E-PAP protocols were associated with a significant increase in the length of hospital stay, resulting in an additional expenditure of $244.4 per episode for the E-PAP 72 hours protocol compared with PAP 24 hours and $309.8 per episode for the E-PAP >48 hours protocol compared with PAP <48 hours. » E-PAP does not demonstrate any significant reduction in the rate of SSIs following spine surgery. However, these extended protocols were significantly associated with an increase in the length of hospital stay and higher overall projected costs. Level of Evidence: Level I. See Instructions for Authors for a complete description of levels of evidence.