Gabriela Gavilan Hadid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gabriela Gavilan Hadid has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Christiano Oliveira-Santos
Department of Diagnosis and Oral Health, University of Louisville School of Dentistry, Louisville, USA
2 shared publications - Deborah Queiroz Freitas
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
2 shared publications - Gustavo Machado Santaella
Assistant Professor, Radiology and Imaging Sciences, Department of Diagnosis and Oral Health, University of Louisville, Louisville, KY, USA
2 shared publications - Débora Costa Ruiz
Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Espírito Santo, Brazil
1 shared publication - Fabiane Carneiro Lopes-Olhê
Department of Restorative Dentistry, Dental School of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Brazil
1 shared publication - Francisco Carlos Groppo
Department of Biosciences, Faculdade de Odontologia de Piracicaba (FOP), Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP, Brazil
1 shared publication
Latest Publications
- 21 May 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (7) , 743-750
Diagnostic performance of a novel wireless direct-conversion intraoral sensor versus complementary metal-oxide semiconductor and photostimulable storage phosphor systems for proximal caries detection: an ex vivo study
Objectives: To compare the diagnostic accuracy of a new wireless direct-conversion digital intraoral sensor to current indirect-conversion complementary metal-oxide semiconductor (CMOS) and photostimulable storage phosphor (PSP) sensors for detecting proximal caries. Methods: The sample in this ex vivo study were 28 human premolars with 21 micro-CT verified non-cavitated proximal dental carious lesions. Images were obtained using 3 digital intraoral systems: a wireless direct-conversion sensor, a wired indirect-conversion CMOS sensor, and a PSP sensor. A custom phantom was constructed providing a limited dental arch segment comprising a molar, first premolar, and canine. The premolar was substituted and the phantom imaged using each intraoral system with (filtered) and without (raw) the application of a manufacturer-recommended enhancements, providing 168 images. Eight oral radiologists assessed the images using a 5-point scale. Receiver operating characteristic analysis was performed to calculate sensitivity, specificity, and the area under the curve (AUC) and compared across modalities using 2-way analysis of variance (ANOVA) with post hoc Tukey’s test at an a priori level of significance of 0.05. Results: The AUC ranged from 0.58 to 0.73 (sensitivity range: 0.21-0.68, specificity range: 0.69-0.92). The wireless direct-conversion sensor (0.72 ± 0.06) showed diagnostic performance comparable to CMOS (0.72 ± 0.06) and superior to PSP (0.58 ± 0.07) for raw images (P < .001). The direct-conversion sensor without image enhancement (0.68 ± 0.18) demonstrated the highest sensitivity, whereas the PSP without image enhancement (0.21 ± 0.09) had the lowest sensitivity. Application of image enhancement improved PSP performance (0.48 ± 0.16), approximating that of the other systems. Conclusions: Based on this ex vivo study, the wireless direct-conversion and CMOS sensors demonstrated similar diagnostic performance, superior to PSP in unfiltered conditions. These findings should be interpreted in light of the ex vivo design and modest sample size.
- 21 May 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (7) , 743-750
Diagnostic performance of a novel wireless direct-conversion intraoral sensor versus complementary metal-oxide semiconductor and photostimulable storage phosphor systems for proximal caries detection: an ex vivo study
Objectives: To compare the diagnostic accuracy of a new wireless direct-conversion digital intraoral sensor to current indirect-conversion complementary metal-oxide semiconductor (CMOS) and photostimulable storage phosphor (PSP) sensors for detecting proximal caries. Methods: The sample in this ex vivo study were 28 human premolars with 21 micro-CT verified non-cavitated proximal dental carious lesions. Images were obtained using 3 digital intraoral systems: a wireless direct-conversion sensor, a wired indirect-conversion CMOS sensor, and a PSP sensor. A custom phantom was constructed providing a limited dental arch segment comprising a molar, first premolar, and canine. The premolar was substituted and the phantom imaged using each intraoral system with (filtered) and without (raw) the application of a manufacturer-recommended enhancements, providing 168 images. Eight oral radiologists assessed the images using a 5-point scale. Receiver operating characteristic analysis was performed to calculate sensitivity, specificity, and the area under the curve (AUC) and compared across modalities using 2-way analysis of variance (ANOVA) with post hoc Tukey’s test at an a priori level of significance of 0.05. Results: The AUC ranged from 0.58 to 0.73 (sensitivity range: 0.21-0.68, specificity range: 0.69-0.92). The wireless direct-conversion sensor (0.72 ± 0.06) showed diagnostic performance comparable to CMOS (0.72 ± 0.06) and superior to PSP (0.58 ± 0.07) for raw images (P < .001). The direct-conversion sensor without image enhancement (0.68 ± 0.18) demonstrated the highest sensitivity, whereas the PSP without image enhancement (0.21 ± 0.09) had the lowest sensitivity. Application of image enhancement improved PSP performance (0.48 ± 0.16), approximating that of the other systems. Conclusions: Based on this ex vivo study, the wireless direct-conversion and CMOS sensors demonstrated similar diagnostic performance, superior to PSP in unfiltered conditions. These findings should be interpreted in light of the ex vivo design and modest sample size.
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 273
Evaluation of image quality in conventional intraoral radiographs acquired with a stationary intraoral tomosynthesis system
Ruiz DC, et al. Imaging Sci Dent. 2026 ;56:e21. https://doi.org/10.5624/isd.20260080
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 273
Open AccessEvaluation of image quality in conventional intraoral radiographs acquired with a stationary intraoral tomosynthesis system
Ruiz DC, et al. Imaging Sci Dent. 2026 ;56:e21. https://doi.org/10.5624/isd.20260080
- 31 July 2024
- Published by Elsevier in Journal of Endodontics
- Vol. 50 (10) , 1495-1504
Influence of Initial Root Canal Treatment on Intratubular Penetrability and Bond Strength of Nonsurgical Retreatment: An In Vitro Study
- 31 July 2024
- Published by Elsevier in Journal of Endodontics
- Vol. 50 (10) , 1495-1504
Influence of Initial Root Canal Treatment on Intratubular Penetrability and Bond Strength of Nonsurgical Retreatment: An In Vitro Study