Dide Tekinarslan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dide Tekinarslan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Damla Erkal
Department of Endodontics, Faculty of Dentistry Burdur Mehmet Akif Ersoy University Burdur Turkiye
4 shared publications - Kürşat Er
Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
4 shared publications - Simay Koç
Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
4 shared publications Ali Osman Kiliç
Department of Medical Microbiology, Faculty of Medicine Karadeniz Technical University Trabzon Türkiye
1 shared publication- Atadeniz Toros
Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
1 shared publication - Esen Ercan
Akdeniz University, Faculty of Dentistry
1 shared publication
Latest Publications
- Open Access
- 30 June 2025
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 62 (3) , 521-526
Accuracy of electronic apex locators in the determination of the working length in teeth with natural apical root resorption in the presence of different irrigation solutions
Root resorption (RR) is usually a consequence of dental trauma, pulpal infection, primary occlusal pressure, or orthodontic tooth movement, leading to the loss of anatomical root formation. As a result of apical RR, the apical constriction is destroyed, and the determination of the working length (WL) may become difficult. The purpose of the present study was to evaluate the accuracy of 4 different electronic apex locators (EALs) - ProPex® II, Propex Pixi®, DentaPort ZX, and DTE DPEX V - in the determination of WL in teeth with natural apical RR in the presence of different irrigation solutions (ISs). A total of 36 teeth with natural apical RR were included in the study. The actual length (AL) was determined under a stereomicroscope at ×15 magnification. Afterward, the electronic length (EL) was established by using 4 different EALs in the presence of different ISs. The ISs used in the measurements were freshly prepared, and 6 groups were organized based on the solution used. The control group was marked as group 1. For groups 2-6, 1% sodium hypochlorite (NaOCl), 2.5% NaOCl, saline, 2% chlorhexidine (CHX), and 17% ethylenediaminetetraacetic acid (EDTA) were used, respectively. After each measurement, the roots were washed with 5 mL of distilled water and dried with paper points before the same teeth were used in the subsequent group. The absolute length was subtracted from EL for each tooth to calculate the difference. The data was analyzed statistically. For each device, there were no significant differences in the success rates between the ISs used. In group 1, there were no significant differences among the 4 EALs. In group 2, DentaPort ZX was significantly more successful than DTE DPEX V (p = 0.037). There were no significant differences among EALs in groups 3-6. The difference between DentaPort ZX and DTE DPEX V was statistically significant in group 2 (1% NaOCl).
- 30 June 2025
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 62 (3) , 521-526
Open AccessAccuracy of electronic apex locators in the determination of the working length in teeth with natural apical root resorption in the presence of different irrigation solutions
Root resorption (RR) is usually a consequence of dental trauma, pulpal infection, primary occlusal pressure, or orthodontic tooth movement, leading to the loss of anatomical root formation. As a result of apical RR, the apical constriction is destroyed, and the determination of the working length (WL) may become difficult. The purpose of the present study was to evaluate the accuracy of 4 different electronic apex locators (EALs) - ProPex® II, Propex Pixi®, DentaPort ZX, and DTE DPEX V - in the determination of WL in teeth with natural apical RR in the presence of different irrigation solutions (ISs). A total of 36 teeth with natural apical RR were included in the study. The actual length (AL) was determined under a stereomicroscope at ×15 magnification. Afterward, the electronic length (EL) was established by using 4 different EALs in the presence of different ISs. The ISs used in the measurements were freshly prepared, and 6 groups were organized based on the solution used. The control group was marked as group 1. For groups 2-6, 1% sodium hypochlorite (NaOCl), 2.5% NaOCl, saline, 2% chlorhexidine (CHX), and 17% ethylenediaminetetraacetic acid (EDTA) were used, respectively. After each measurement, the roots were washed with 5 mL of distilled water and dried with paper points before the same teeth were used in the subsequent group. The absolute length was subtracted from EL for each tooth to calculate the difference. The data was analyzed statistically. For each device, there were no significant differences in the success rates between the ISs used. In group 1, there were no significant differences among the 4 EALs. In group 2, DentaPort ZX was significantly more successful than DTE DPEX V (p = 0.037). There were no significant differences among EALs in groups 3-6. The difference between DentaPort ZX and DTE DPEX V was statistically significant in group 2 (1% NaOCl).
- Open Access
- 23 April 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 88 (9) , 2586-2593
The Effect of Various Irrigants on Mixed Biofilms in Dentinal Tubules: A Confocal Laser Scanning Microscopy Study
This study evaluated the bacterial disinfection efficacy of three different irrigation solutions and their combined usage in dentin tubules contaminated with mixed biofilms. A total of 60 single‐rooted mandibular premolars were prepared with ProTaper Next X4, sterilized, and then inoculated with mixed biofilm for 7 days. After biofilm formation, the teeth were randomly divided into six groups (n = 10) based on the irrigation solution used: Group 1: sodium hypochlorite (NaOCl), Group 2: chlorhexidine gluconate (CHX), Group 3: polyhexamethylene biguanide (PHMB), Group 4: NaOCl + CHX, Group 5: NaOCl + PHMB, Group 6: distilled water (control group). The teeth were sectioned at the coronal, middle, and apical thirds and stained with LIVE/DEAD BackLight and examined under a confocal laser scanning microscope (CLSM) to determine the depth of dead bacterial penetration into the dentinal tubules. Additionally, one tooth from each group was subjected to bacterial viable counting before and after irrigation. The CLSM analysis revealed that the greatest penetration of dead bacteria occurred in the coronal third, followed by the apical and middle third (p < 0.05). Combined solutions demonstrated significantly higher disinfection efficacy compared with PHMB alone (p < 0.001). Viable count analysis revealed that Group 4 and Group 5 exhibited the greatest reduction in bacterial proliferation, respectively. The combined use of solutions was found to be more effective than the sole use of solutions. Therefore, it is recommended to combine irrigation solutions during final irrigation in clinical settings.
- 23 April 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 88 (9) , 2586-2593
Open AccessThe Effect of Various Irrigants on Mixed Biofilms in Dentinal Tubules: A Confocal Laser Scanning Microscopy Study
This study evaluated the bacterial disinfection efficacy of three different irrigation solutions and their combined usage in dentin tubules contaminated with mixed biofilms. A total of 60 single‐rooted mandibular premolars were prepared with ProTaper Next X4, sterilized, and then inoculated with mixed biofilm for 7 days. After biofilm formation, the teeth were randomly divided into six groups (n = 10) based on the irrigation solution used: Group 1: sodium hypochlorite (NaOCl), Group 2: chlorhexidine gluconate (CHX), Group 3: polyhexamethylene biguanide (PHMB), Group 4: NaOCl + CHX, Group 5: NaOCl + PHMB, Group 6: distilled water (control group). The teeth were sectioned at the coronal, middle, and apical thirds and stained with LIVE/DEAD BackLight and examined under a confocal laser scanning microscope (CLSM) to determine the depth of dead bacterial penetration into the dentinal tubules. Additionally, one tooth from each group was subjected to bacterial viable counting before and after irrigation. The CLSM analysis revealed that the greatest penetration of dead bacteria occurred in the coronal third, followed by the apical and middle third (p < 0.05). Combined solutions demonstrated significantly higher disinfection efficacy compared with PHMB alone (p < 0.001). Viable count analysis revealed that Group 4 and Group 5 exhibited the greatest reduction in bacterial proliferation, respectively. The combined use of solutions was found to be more effective than the sole use of solutions. Therefore, it is recommended to combine irrigation solutions during final irrigation in clinical settings.
- 1 January 2025
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 67 (4) , 161-166
Effect of precipitate formation in the root canal on the accuracy of electronic apex locators
This study evaluated how the formation of various types of precipitates affects the accuracy of electronic apex locators in determining the working length. Two hundred and forty extracted human maxillary incisors were selected. A total of eight groups were used: four groups (n = 30) for the application of different irrigants; saline, sodium hypochlorite (5.25% NaOCl), chlorhexidine (2% CHX) and ethylenediaminetetraacetic acid (EDTA) (17% EDTA), and four groups (n = 30) for the formation of precipitates; orange-brown (2% CHX + 5.25% NaOCl), orange-white (2%CHX + 0.16% NaOCl), white milky (2% CHX + 17% EDTA), salt (2% CHX + saline). Electronic working length was determined by two different electronic apex locators. The success rate of the 5.25% NaOCl group was significantly higher than that of the white milky precipitate group. The electronic apex locators were highly effective in identifying working length, but the success rate of both devices declined due to the production of a white milky precipitate. The study emphasizes the importance of selecting appropriate irrigation protocols for optimal treatment outcomes, as the chemical interactions between solutions and precipitates significantly influence electronic apex locator measurements, highlighting the need for careful consideration of irrigant compatibility.
- 1 January 2025
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 67 (4) , 161-166
Effect of precipitate formation in the root canal on the accuracy of electronic apex locators
This study evaluated how the formation of various types of precipitates affects the accuracy of electronic apex locators in determining the working length. Two hundred and forty extracted human maxillary incisors were selected. A total of eight groups were used: four groups (n = 30) for the application of different irrigants; saline, sodium hypochlorite (5.25% NaOCl), chlorhexidine (2% CHX) and ethylenediaminetetraacetic acid (EDTA) (17% EDTA), and four groups (n = 30) for the formation of precipitates; orange-brown (2% CHX + 5.25% NaOCl), orange-white (2%CHX + 0.16% NaOCl), white milky (2% CHX + 17% EDTA), salt (2% CHX + saline). Electronic working length was determined by two different electronic apex locators. The success rate of the 5.25% NaOCl group was significantly higher than that of the white milky precipitate group. The electronic apex locators were highly effective in identifying working length, but the success rate of both devices declined due to the production of a white milky precipitate. The study emphasizes the importance of selecting appropriate irrigation protocols for optimal treatment outcomes, as the chemical interactions between solutions and precipitates significantly influence electronic apex locator measurements, highlighting the need for careful consideration of irrigant compatibility.
- Open Access
- 30 September 2024
- Published by Sociedade Portuguesa de Estomatologia e Medicina Dentaria (SPEMD) in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
- Vol. 65 (3) , 121-128
Effects of irrigation activation techniques on root canal walls after post-space preparation: A scanning electron microscopy study
Objectives: To evaluate the effect of different irrigation activation techniques (IATs) on smear layer removal after post-space preparation. Methods: Forty single-rooted mandibular premolars with no root canal treatment were selected. Teeth were decoronated at 15 mm, and apical patency was confirmed using a #10 K-file. The ProTaper Next NiTi file system was used to shape the root canal. Afterward, the root canals were filled with gutta-percha and a root canal sealer. A week later, 10-mm postspace preparation was done. Teeth were randomly divided into 4 groups based on the IATs used to activate 3 mL of 17% EDTA for 1 min: 1) control group with a conventional needle; 2) sonic irrigation (SI); 3) passive ultrasonic irrigation (PUI); and 4) laser-activated irrigation (LAI). Teeth were split longitudinally, and specimens were observed under a scanning electron microscope. Images were taken at the teeth’ coronal, middle, and apical thirds at ×2000 magnification and were scored based on the presence of the smear layer. Data were analyzed statistically. Results: No statistically significant difference was observed between the IATs regarding smear layer removal (p>0.05). However, PUI was more successful at the coronal and apical third, and SI was more successful in the middle third. Conclusions: All the used IATs were effective in removing the smear layer. However, none of them removed it completely.
- 30 September 2024
- Published by Sociedade Portuguesa de Estomatologia e Medicina Dentaria (SPEMD) in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
- Vol. 65 (3) , 121-128
Open AccessEffects of irrigation activation techniques on root canal walls after post-space preparation: A scanning electron microscopy study
Objectives: To evaluate the effect of different irrigation activation techniques (IATs) on smear layer removal after post-space preparation. Methods: Forty single-rooted mandibular premolars with no root canal treatment were selected. Teeth were decoronated at 15 mm, and apical patency was confirmed using a #10 K-file. The ProTaper Next NiTi file system was used to shape the root canal. Afterward, the root canals were filled with gutta-percha and a root canal sealer. A week later, 10-mm postspace preparation was done. Teeth were randomly divided into 4 groups based on the IATs used to activate 3 mL of 17% EDTA for 1 min: 1) control group with a conventional needle; 2) sonic irrigation (SI); 3) passive ultrasonic irrigation (PUI); and 4) laser-activated irrigation (LAI). Teeth were split longitudinally, and specimens were observed under a scanning electron microscope. Images were taken at the teeth’ coronal, middle, and apical thirds at ×2000 magnification and were scored based on the presence of the smear layer. Data were analyzed statistically. Results: No statistically significant difference was observed between the IATs regarding smear layer removal (p>0.05). However, PUI was more successful at the coronal and apical third, and SI was more successful in the middle third. Conclusions: All the used IATs were effective in removing the smear layer. However, none of them removed it completely.
- 30 September 2024
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 14 (3) , 727-732
Does Root Canal Shaping Effect the Accuracy of Electronic Apex Locators in Curved and Straight Root Canals?
Objective: To assess the influence of root canal preparation (RCP) on the precision of electronic apex locators (EALs) in both straight and curved root canals. Methods: The experimental setup included forty-two extracted human mandibular molars featuring both straight distal canals (0-10 degrees) and curved mesial root canals (30-50 degrees). Initial working length (AWL1) measurements were conducted under a stereomicroscope at X15 magnification prior to root canal preparation (RCP). Subsequently, electronic working length (EWL1) was determined using two different electronic apex locators (EALs) – Propex-Pixi and EndoRadar. RCP was carried out with ProTaper Ultimate F1, F2 files in mesial canals, and F1, F2, F3 files in distal straight root canals. The RCP procedure involved the implementation of a standard irrigation protocol along with the use of a sonic device for activation. Following RCP, measurements were repeated under a stereomicroscope and documented as AWL2. EWL measurements were also repeated and recorded as EWL2 after the preparation. The variation was calculated by subtracting AWL from EWL for each tooth (EWL1-AWL1 and EWL2-AWL2). Statistical analysis employed Paired Sample t-test and Wilcoxon tests. Results: There was no statistically significant difference observed in the accuracy of Propex-Pixi and EndoRadar Pro before and after root canal preparation for both straight and curved canals. Conclusion: Root canal preparation did not alter the accuracy of the electronic apex locators (EALs) used in this study, whether applied to curved or straight root canals.
- 30 September 2024
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 14 (3) , 727-732
Does Root Canal Shaping Effect the Accuracy of Electronic Apex Locators in Curved and Straight Root Canals?
Objective: To assess the influence of root canal preparation (RCP) on the precision of electronic apex locators (EALs) in both straight and curved root canals. Methods: The experimental setup included forty-two extracted human mandibular molars featuring both straight distal canals (0-10 degrees) and curved mesial root canals (30-50 degrees). Initial working length (AWL1) measurements were conducted under a stereomicroscope at X15 magnification prior to root canal preparation (RCP). Subsequently, electronic working length (EWL1) was determined using two different electronic apex locators (EALs) – Propex-Pixi and EndoRadar. RCP was carried out with ProTaper Ultimate F1, F2 files in mesial canals, and F1, F2, F3 files in distal straight root canals. The RCP procedure involved the implementation of a standard irrigation protocol along with the use of a sonic device for activation. Following RCP, measurements were repeated under a stereomicroscope and documented as AWL2. EWL measurements were also repeated and recorded as EWL2 after the preparation. The variation was calculated by subtracting AWL from EWL for each tooth (EWL1-AWL1 and EWL2-AWL2). Statistical analysis employed Paired Sample t-test and Wilcoxon tests. Results: There was no statistically significant difference observed in the accuracy of Propex-Pixi and EndoRadar Pro before and after root canal preparation for both straight and curved canals. Conclusion: Root canal preparation did not alter the accuracy of the electronic apex locators (EALs) used in this study, whether applied to curved or straight root canals.