Di Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Di Sun has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jin Liu
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
2 shared publications - Kexin Xu
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
2 shared publications - Qing Ge
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
2 shared publications - Tongshuai Han
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
2 shared publications - Jiayu Chen
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publication - Rong Liu
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
1 shared publication
Latest Publications
- Open Access
Design Key Points of High-Performance Diffuse Reflectance Optical Sensors for Non-Invasive Blood Glucose Measurement
Optical sensors serve as pivotal components in the realm of non-invasive blood glucose measurement (NBGM) devices, where their efficacy directly influences the detection of weak glucose signals. This research introduces three fundamental design key points tailored for diffuse reflectance optical sensors employed for NBGM: depth resolution, detection signal-to-noise ratio, and human–sensor interface coupling. Guided by these design key points, we presented feasible design proposals for near-infrared diffuse reflectance sensors operating in the range of 1000–1700 nm. As an example, a sensor composed of five-ring detectors with a ring-shaped mask were made and tested on human skin. The innovative sensor developed herein holds promising potential for NBGM.
Open AccessDesign Key Points of High-Performance Diffuse Reflectance Optical Sensors for Non-Invasive Blood Glucose Measurement
Optical sensors serve as pivotal components in the realm of non-invasive blood glucose measurement (NBGM) devices, where their efficacy directly influences the detection of weak glucose signals. This research introduces three fundamental design key points tailored for diffuse reflectance optical sensors employed for NBGM: depth resolution, detection signal-to-noise ratio, and human–sensor interface coupling. Guided by these design key points, we presented feasible design proposals for near-infrared diffuse reflectance sensors operating in the range of 1000–1700 nm. As an example, a sensor composed of five-ring detectors with a ring-shaped mask were made and tested on human skin. The innovative sensor developed herein holds promising potential for NBGM.
- Open Access
Evaluation and Validation on Sensitivity of Near-Infrared Diffuse Reflectance in Non-Invasive Human Blood Glucose Measurement
In non-invasive blood glucose measurement, the sensitivity of glucose-induced optical signals within human tissue is a crucial reference point. This study evaluates the sensitivity of glucose-induced diffuse reflectance in the 1000–1700 nm range. A key factor in understanding this sensitivity is the rate at which the scattering coefficient changes due to glucose, as it is significantly higher than in non-living media and predominantly influences the diffuse light signal level when blood glucose levels change. The study measured and calculated the changes in the scattering coefficient at 1314 nm, a wavelength chosen for its minimal interference from glucose absorption and other bodily constituents. Based on the Mie scattering theory and the results at 1314 nm, the changes in the scattering coefficient within the 1000–1700 nm range were estimated. Subsequently, the sensitivity of the glucose signal across this range was determined through Monte Carlo (MC) simulations. The findings from 25 human trials indicate that the measured sensitivities at five other typical wavelengths within this band generally align with the sensitivities calculated using the aforementioned method. This research can guide the identification of blood glucose signals and the selection of wavelengths for non-invasive blood glucose measurements.
Open AccessEvaluation and Validation on Sensitivity of Near-Infrared Diffuse Reflectance in Non-Invasive Human Blood Glucose Measurement
In non-invasive blood glucose measurement, the sensitivity of glucose-induced optical signals within human tissue is a crucial reference point. This study evaluates the sensitivity of glucose-induced diffuse reflectance in the 1000–1700 nm range. A key factor in understanding this sensitivity is the rate at which the scattering coefficient changes due to glucose, as it is significantly higher than in non-living media and predominantly influences the diffuse light signal level when blood glucose levels change. The study measured and calculated the changes in the scattering coefficient at 1314 nm, a wavelength chosen for its minimal interference from glucose absorption and other bodily constituents. Based on the Mie scattering theory and the results at 1314 nm, the changes in the scattering coefficient within the 1000–1700 nm range were estimated. Subsequently, the sensitivity of the glucose signal across this range was determined through Monte Carlo (MC) simulations. The findings from 25 human trials indicate that the measured sensitivities at five other typical wavelengths within this band generally align with the sensitivities calculated using the aforementioned method. This research can guide the identification of blood glucose signals and the selection of wavelengths for non-invasive blood glucose measurements.