CXChi Xu

Chi Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chi Xu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Swift : Turning Your Hand into a Writing Pad with Unmodified Smartwatches

    by Wentao Xie, Yankai Zhao, Chi Xu, Zhengyan Lambo Qin, Yixuan Liu, Jin Zhang, Qian Zhang

    Smartwatches remain constrained by small touchscreens. To enable expressive text input without extra hardware, we introduce Swift , an on-skin writing technique that treats the back of the hand as a passive handwriting pad to capture handwritten English letters and gestures with an unmodified commercial smartwatch. The core design rationale is that Swift measures high-frequency finger-on-skin friction acoustics and complements them with active ultrasonic probing to better recognize characters with similar stroke trajectories. A lightweight cross-attention fusion model is designed to reliably integrate the two modalities, while robustness is ensured via various augmentation techniques. Across an offline technical evaluation in lab and everyday environments (N=22), Swift achieves a macro F1-score of 0.91 after leave-one-subject-out training and few-shot personalization. A real-time deployment study (N=8) demonstrates phrase composition on the watch with users reporting the system as learnable and engaging. A Wizard-of-Oz comparison study (N=8) further indicates users generally prefer Swift over touchscreen handwriting, with preference increasing for more demanding scenarios such as heads-up text entry.

  • Open Access

    CaReFit: Cost-Effective Cardiorespiratory Fitness Assessment Using Multimodal Sensors

    by Chi Xu, Wentao Xie, Huaning Tan, Zirui Huang, Yanbin Gong, Jin Zhang, Shifang Yang, Qian Zhang

    Cardiorespiratory fitness (CRF) is crucial for maintaining overall health, with VO 2 max (maximal oxygen consumption) and VO 2 AT (oxygen consumption at anaerobic threshold) serving as key physiological indicators. The current gold standard for assessing these metrics is Cardiopulmonary Exercise Testing (CPET), which requires bulky equipment, trained personnel, and significant time, putting it out of reach for most people. In this study, we introduce CaReFit, an innovative and low-cost system that utilizes a single-lead electrocardiogram (ECG) and muscle oxygenation (SmO 2 ) sensors to estimate VO 2 max and VO 2 AT. Our method leverages the coupled behavior of ECG and SmO 2 signals during exercise to predict these critical performance metrics. To mitigate exercise-induced noise in ECG signals, we implement a diffusion-based ECG denoising model trained with a tailored ECG-guided loss function on combined public datasets. Then, our multimodal neural network is specifically designed to leverage physiological insights for accurate CRF predictions. We conducted a deployment of CaReFit with 50 patients in a clinical setting, and evaluated CaReFit under a strict subject-disjoint protocol. Under this leakage-free evaluation, CaReFit achieves a mean absolute percentage error (MAPE) of 9.30% (95% CI: 7.06-11.80) for VO 2 max and 9.49% (95% CI: 7.02-12.12) for VO 2 AT. We further conduct a head-to-head comparison with a commercial portable device, and our system demonstrates similar VO 2 max performance trends under the same session protocol while additionally supporting VO 2 AT estimation. Furthermore, we make our dataset and evaluation code publicly available to facilitate further research and development in this domain.

  • Open Access

    ACLGuard: Physics-Aware Knee Loading Monitoring System for Anterior Cruciate Ligament Injury Prevention Training

    by Baichen Yang, Xinyi Zhang, Xin He, Chi Xu, Wentao Xie, Zuru Liang, Patrick Yung Shu-Hang, Qian Zhang

    Anterior cruciate ligament (ACL) injuries are common in sports and significantly affect athletes' health and performance. Integrating knee adduction moment (KAM) biofeedback into ACL injury prevention training has been shown to effectively reduce injury risk and enable athletes to safely engage in high-risk activities. However, current motion capture-based monitoring methods are impractical for on-field use due to their bulky setups and limited coverage. While Inertial Motion Unit (IMU)-based methods address some of these issues, their poor performance during high-risk tasks limits their applicability in real-world scenarios. This paper presents ACLGuard, a novel physics-aware KAM monitoring system designed for out-of-lab ACL injury prevention training. ACLGuard utilizes a combination of continuous monitoring with a set of IMUs and a one-time body capture with RGB-D camera. We identify key limitations in existing approaches, including insufficient body information and inadequate encoding of biomechanical principles. To overcome these challenges, we introduce a one-time RGB-D registration scheme to capture comprehensive body information and develop an inverse dynamics (ID)-guided modeling algorithm to incorporate biomechanical principles into the system. However, extracting kinematic features under high-risk conditions and obtaining representative body features with respect to ID principle are challenging. Even worse, these extracted imperfect features increase the ID-guided modeling difficulty for KAM estimation. To derive meaningful physical features, we propose a hybrid deep learning model referring to motion patterns and physical priors. For ID-guided modeling, we introduce an attention-enhanced multi-task learning framework to establish hidden physical mappings from imperfect features to KAM. We collect a dataset from 10 athletes and 9 non-athlete subjects, containing four main high-risk tasks in real-world ACL injury prevention. Evaluations show that ACLGuard achieves an average root mean square error of 0.176 Nm/kg and a normalized root mean square error of 11.5% in KAM estimation, comparable to existing markerless motion capture solutions but offers an on-field monitoring potential with a significantly simpler setup.

  • Open Access

    EasySpiro: Assessing Lung Function via Arbitrary Exhalations on Commodity Earphones

    by Chi Xu, Wentao Xie, Baichen Yang, Yizhen Zhang, Yanbin Gong, Jin Zhang, Wei Li, Shifang Yang, Qian Zhang


  • Open Access

    AI-Driven Smartphone Screening for Acute COPD Exacerbations: A Non-Self-Report Approach to Improve Health Equity in Developing Regions

    by Yanbin Gong, Chi Xu, Caixia Mo, Jianhui Wu, Huiyong Lin, Huaan Su, Qingpeng Zhang, Qian Zhang, Shifang Yang

    Acute exacerbations of chronic obstructive pulmonary disease (AECOPD) are critical clinical events that necessitate prompt intervention. However, their detection remains challenging in primary care settings, especially in resource-limited regions. A lack of disease awareness among both patients and healthcare providers often leads to delayed diagnoses and suboptimal management. To address this issue, we developed an AI-based AECOPD detection system that leverages standard mobile phone microphones for auscultation, specifically designed for novice users and eliminating the need for subjective symptom assessments or patientreported scales. Our system demonstrated robust performance in automatically detecting exacerbations, achieving an area under the curve (AUC) of 0.955 (95% CI: 0.929-0.976). This research highlights the potential of AI-driven solutions to enhance COPD management in underserved populations with limited access to specialist medical resources, thereby promoting health equity. The digital health system shows promise for improved long-term management of COPD and is projected to save 41.81 billion CNY (Median: 24.25 billion, 95% CI: -7.75-198.33 billion), particularly benefiting primary care settings where access to pulmonary specialists is constrained.

  • Open Access

    SputumLocator: Enhancing Airway Clearance with Auscultation-based Sputum Localization

    by Yanbin Gong, Wentao Xie, Chi Xu, Qian Zhang, Shifang Yang

    Airway clearance is essential for managing Muco-Obstructive Lung Diseases (MOLDs). Percussion, a widely used airway clearance technique (ACT) in community and home care settings, is favored for its ease of implementation compared to other complex techniques. However, percussion is time-consuming and physically demanding for both caregivers and patients, as caregivers typically perform percussion on the entire back to avoid missing accumulated sputum when its exact location is unknown. Therefore, accurate sputum localization can significantly enhance the percussion experience. Current clinical methods for sputum localization typically rely on imaging techniques, which are costly, expose patients to radiation, and are usually performed only once during diagnosis, thereby limiting their application to inpatient settings. Alternatively, some medical professionals combine auscultation with other clinical assessments, but this approach requires substantial clinical experience and is impractical for community or home care settings where medical experts are unavailable. To address these limitations, we introduce SputumLocator, an innovative sputum localization system based on digital stethoscopes. SputumLocator leverages standard auscultation procedures to detect accumulated sputum in the four quadrants of the back, which is straightforward and highly practical. SputumLocator comprises two components: SputumEmbedder, which extracts key abnormal sounds and their spatial features using a Transformer-based feature extractor, and SputumClassifier, which maps these features to determine sputum presence in each region via a Convolutional Block Attention Module (CBAM). Given the limited availability of annotated sputum data, we developed a pretraining method based on Embedding on Masked Data (EOM) and enhanced model robustness through a Teacher-Student Architecture (TSA) that integrates noisy data. In collaboration with a medical institution, we evaluate SputumLocator on 43 patients with diverse physiological characteristics and under varying recording conditions. Experimental results demonstrate that SputumLocator achieves high accuracy with an overall sensitivity of 0.97, specificity of 0.82, and F1-Score of 0.83, maintaining robustness across different thoracic regions, genders, and disease types.


  • Open Access

    DeepBreath: Breathing Exercise Assessment with a Depth Camera

    by Wentao Xie, Chi Xu, Yanbin Gong, Yu Wang, Yuxin Liu, Jin Zhang, Qian Zhang, Zeguang Zheng, Shifang Yang

    Practicing breathing exercises is crucial for patients with chronic obstructive pulmonary disease (COPD) to enhance lung function. Breathing mode (chest or belly breathing) and lung volume are two important metrics for supervising breathing exercises. Previous works propose that these metrics can be sensed separately in a contactless way, but they are impractical with unrealistic assumptions such as distinguishable chest and belly breathing patterns, the requirement of calibration, and the absence of body motions. In response, this research proposes DeepBreath, a novel depth camera-based breathing exercise assessment system, to overcome the limitations of the existing methods. DeepBreath, for the first time, considers breathing mode and lung volume as two correlated measurements and estimates them cooperatively with a multitask learning framework. This design boosts the performance of breathing mode classification. To achieve calibration-free lung volume measurement, DeepBreath uses a data-driven approach with a novel UNet-based deep-learning model to achieve one-model-fit-all lung volume estimation, and it is designed with a lightweight silhouette segmentation model with knowledge transferred from a state-of-the-art large segmentation model that enhances the estimation performance. In addition, DeepBreath is designed to be resilient to involuntary motion artifacts with a temporal-aware body motion compensation algorithm. We collaborate with a clinical center and conduct experiments with 22 healthy subjects and 14 COPD patients to evaluate DeepBreath. The experimental result shows that DeepBreath can achieve high breathing metrics estimation accuracy but with a much more realistic setup compared with previous works.