Jinchao Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jinchao Cao has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Han
Department of Pediatric Orthopaedics The Third Hospital of Hebei Medical University Shijiazhuang China
1 shared publication - Jingwei Liu
Department of Power Engineering North China Electric Power University Baoding Hebei 071003 China
1 shared publication Jun‐Zhong Luo
Department of Pediatric Orthopaedics The Third Hospital of Hebei Medical University Shijiazhuang China
1 shared publication- Lei Wang
The Key Laboratory of the Inorganic Molecule‐Based Chemistry of Liaoning Province and Laboratory of Coordination Chemistry Shenyang University of Chemical Technology Shenyang Liaoning China
1 shared publication Meng‐Meng Du
Department of Pediatric Orthopaedics The Third Hospital of Hebei Medical University Shijiazhuang China
1 shared publication- Mingchang Zhu
Shenyang University of Chemical Technology
1 shared publication
Latest Publications
- 3 September 2024
- Published by Wiley in Applied Organometallic Chemistry
- Vol. 38 (12)
Multicentric Water‐Stabilized Lanthanide Coordination Polymers for the Highly Sensitive and Rapid Detection of Riboflavin
Milk, owing to its nutritional value, is a staple commodity in daily life. Ensuring its integrity and authenticity is paramount for researchers and the food industry. To evaluate spoilage and adulteration of milk, we proposed a robust and reliable optical method to guarantee milk quality by utilizing riboflavin as an internal biomarker. By precisely controlling the content of Eu3+, Tb3+, and Gd3+ ions, a two‐dimensional ratiometric luminescence lanthanide coordination polymer (Ln‐CP) with adjustable emission centers was synthesized for the detection of riboflavin (RF), leveraging a Förster resonance energy transfer (FRET) and photoinduced electron transfer (PET) process. This method demonstrates high sensitivity and selectivity towards RF and has been successfully applied to the detection of RF in both milk and calf serum.
- 3 September 2024
- Published by Wiley in Applied Organometallic Chemistry
- Vol. 38 (12)
Multicentric Water‐Stabilized Lanthanide Coordination Polymers for the Highly Sensitive and Rapid Detection of Riboflavin
Milk, owing to its nutritional value, is a staple commodity in daily life. Ensuring its integrity and authenticity is paramount for researchers and the food industry. To evaluate spoilage and adulteration of milk, we proposed a robust and reliable optical method to guarantee milk quality by utilizing riboflavin as an internal biomarker. By precisely controlling the content of Eu3+, Tb3+, and Gd3+ ions, a two‐dimensional ratiometric luminescence lanthanide coordination polymer (Ln‐CP) with adjustable emission centers was synthesized for the detection of riboflavin (RF), leveraging a Förster resonance energy transfer (FRET) and photoinduced electron transfer (PET) process. This method demonstrates high sensitivity and selectivity towards RF and has been successfully applied to the detection of RF in both milk and calf serum.
- Open Access
- 4 February 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 11 (1) , 102-108
External Fixator‐assisted Ulnar Osteotomy: A Novel Technique to Treat Missed Monteggia Fracture in Children
Objective: The treatment of missed Monteggia fracture remains a challenge, despite the various surgical methods described. The purpose of this study was to explore a new surgical technique utilizing external fixator‐assisted ulnar osteotomy and to assess the surgical results in a case series.Methods: Thirteen patients with missed Monteggia fractures were treated at our institution using this new surgical technique from August 2012 to January 2016. Our series included 11 boys and 2 girls. The left elbow was involved in 6 patients and the right elbow was involved in 7 patients. According to the Bado classification, 10 fractures were classified as Bado type I with anterior radial head dislocation and 3 were classified as Bado type III with anterolateral dislocation. The average age at the time of surgery was 5 years 8 months (range, 2 years 2 months–10 years). The mean trauma‐to‐surgery interval was 12 months (range, 2–36 months). All patients underwent ulnar osteotomy with angulation and lengthening using a temporary external fixator, plate fixation of the osteotomy, and open reduction of the radial head dislocation without annular ligament reconstruction.Results: The average follow‐up was 27 months (range, 16–44 months). The average operation time was 175 min (range, 140–215 min). The average length of distraction was 0.7 cm (range, 0.5–1.2 cm) and the average angulation was 28° (range, 20°–30°) at the ulnar osteotomy site intraoperatively. The elbow performance score (Kim's) was excellent in 10 cases and good in 3 cases. No neurovascular complications, compartment syndrome or implant breakage occurred. No pain in the distal radioulnar joint or limited range of motion of the wrist occurred in any patient. The radial head remained reduced in all patients with no subluxation or redislocation. However, delayed ulnar union occurred in 3 cases, all of which were successfully treated with plaster cast immobilization within approximately 6 months postoperatively. One patient presented with cubitus valgus postoperatively with a carrying angle of 30°, which was 10° greater than the contralateral carrying angle.Conclusions: External fixator‐assisted ulnar osteotomy offers substantial flexibility for achieving the optimal positioning of the transected ulna to reduce the radial head prior to the final ulnar osteotomy fixation with a plate, thereby facilitating an effective operative performance. Our procedure is a safe and effective method to treat missed pediatric Monteggia fractures.
- 4 February 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 11 (1) , 102-108
Open AccessExternal Fixator‐assisted Ulnar Osteotomy: A Novel Technique to Treat Missed Monteggia Fracture in Children
Objective: The treatment of missed Monteggia fracture remains a challenge, despite the various surgical methods described. The purpose of this study was to explore a new surgical technique utilizing external fixator‐assisted ulnar osteotomy and to assess the surgical results in a case series.Methods: Thirteen patients with missed Monteggia fractures were treated at our institution using this new surgical technique from August 2012 to January 2016. Our series included 11 boys and 2 girls. The left elbow was involved in 6 patients and the right elbow was involved in 7 patients. According to the Bado classification, 10 fractures were classified as Bado type I with anterior radial head dislocation and 3 were classified as Bado type III with anterolateral dislocation. The average age at the time of surgery was 5 years 8 months (range, 2 years 2 months–10 years). The mean trauma‐to‐surgery interval was 12 months (range, 2–36 months). All patients underwent ulnar osteotomy with angulation and lengthening using a temporary external fixator, plate fixation of the osteotomy, and open reduction of the radial head dislocation without annular ligament reconstruction.Results: The average follow‐up was 27 months (range, 16–44 months). The average operation time was 175 min (range, 140–215 min). The average length of distraction was 0.7 cm (range, 0.5–1.2 cm) and the average angulation was 28° (range, 20°–30°) at the ulnar osteotomy site intraoperatively. The elbow performance score (Kim's) was excellent in 10 cases and good in 3 cases. No neurovascular complications, compartment syndrome or implant breakage occurred. No pain in the distal radioulnar joint or limited range of motion of the wrist occurred in any patient. The radial head remained reduced in all patients with no subluxation or redislocation. However, delayed ulnar union occurred in 3 cases, all of which were successfully treated with plaster cast immobilization within approximately 6 months postoperatively. One patient presented with cubitus valgus postoperatively with a carrying angle of 30°, which was 10° greater than the contralateral carrying angle.Conclusions: External fixator‐assisted ulnar osteotomy offers substantial flexibility for achieving the optimal positioning of the transected ulna to reduce the radial head prior to the final ulnar osteotomy fixation with a plate, thereby facilitating an effective operative performance. Our procedure is a safe and effective method to treat missed pediatric Monteggia fractures.