BYBeste Yilmaz

Beste Yilmaz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Beste Yilmaz has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Validating a Low-Cost Depth Sensor for Facial Anthropometry: Capabilities and Appropriate Use

    by Umut Özsoy, Ege Alkan, Yılmaz Yıldırım, Beste Yılmaz

    Background: Low-cost depth sensors are increasingly proposed for 3D facial capture, with high intraclass correlation coefficients (ICC) cited as evidence of readiness. Intraclass correlation coefficient reflects relative agreement and can stay high even when absolute error is large. Methods: Twelve adults were measured by 2 observers at 16 facial distances. We recomputed device-versus-caliper ICC(3,k), Bland-Altman statistics, observer reliability and measurement error, scan-rescan precision, mean absolute error (MAE), and a tolerance classification, against a structured-light scanner and direct calipers. Results: Device-versus-caliper ICC was high for both classes (0.88 and 0.93). Despite this, the depth-sensor MAE was 2.75 versus 1.64 mm ( P =0.0002), and ICC did not predict absolute error (rho=-0.17, P =0.52). This error matched manual landmark-placement error (SEM 1.6-2.1 mm), so it is only partly device-driven; the sensor was distinguished instead by poorer scan-rescan repeatability (0.84 versus 0.36 mm). On a tolerance scheme, 14 of 16 depth-sensor distances exceeded 2 mm, falling to 7 of 16 for the device-specific component. Conclusions: At a fraction of the cost, the depth sensor reproduces relative ranking well but is less precise on the device-only surface metric. It suits morphometric surveys, ranking, and within-subject monitoring, not high-fidelity reconstruction. A high ICC alone does not establish clinical usability; absolute error must accompany it.

  • Open Access

    The Efficacy and Safety of CollaSel Pro® Hydrolyzed Collagen Peptide Supplementation without Addons in Improving Skin Health in Adult Females: A Double Blind, Randomized, Placebo-Controlled Clinical Study Using Biophysical and Skin Imaging Techniques

    by Devrim Demir-Dora, Umut Ozsoy, Yilmaz Yildirim, Oguz Yilmaz, Peri Aytac, Beste Yilmaz, Emel Dogan Kurtoglu, Ayse Akman, Selim Tezman, Huseyin Serhat Inaloz, et al.

    Background: This study aimed to evaluate the efficacy and safety of oral hydrolyzed collagen peptide (HCP) in healthy females by assessing the skin parameters via biophysical and skin imaging techniques. Methods: 112 females were randomly assigned to receive either HCP (n = 57; 10 g CollaSel Pro®) or placebo (n = 55; 10 g maltodextrin) daily for eight weeks. The contribution of HCP to skin elasticity, hydration, and roughness was investigated against a placebo, while the facial soft tissue sagging (RMS) and safety data were also recorded. Results: HCP was associated with significant improvements in skin elasticity (p = 0.009), skin hydration (p ranged from 0.003 to p ranged from 0.002 to p = 0.017), skin hydration (65.8 (18.9) vs. 53.1 (14.9) g/m3, p < 0.001) and skin roughness (40.2 (20.4) vs. 24.9 (20.9) g/m3, p < 0.001) were significantly higher. In the HCP group, week 8 RMS values were significantly lower than baseline values (1.02 (0.21) vs. 1.10 (0.21) mm, p = 0.012). Conclusions: CollaSel Pro® HCP can be considered a well-tolerated, safe product that effectively improves dermal health and the appearance of sagging and ameliorates the signs of the aging process.