Tongbao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tongbao Li has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Deng
Tongji University
5 shared publications - Xinbin Cheng
Tongji University
5 shared publications - Dongbai Xue
Tongji University
4 shared publications - Chunling He
National Metrology and Testing Center for Integrated Circuit Measurement and Inspection Equipment Industry (Shanghai), Tongji University, Shanghai 200092, People’s Republic of China
3 shared publications - Zhikun Chang
Tongji University
3 shared publications - Zichao Lin
Tongji University
3 shared publications
Latest Publications
- Open Access
- 11 March 2026
- Published by Elsevier in SSRN Electronic Journal
Grating Interferometer Phase Ratio Method for Coefficient-of-Thermal-Expansion Measurement Without Absolute Length Determination
In the era of Atomic and Close-to-Atomic Scale Manufacturing (ACSM), the dimensional stability of ultra-precision systems approaches physical limits, rendering precise measurement of the coefficient of thermal expansion (CTE) critical. Yet, existing methods remain fundamentally constrained by reliance on absolute length measurements susceptible to environmental drift. Here, we introduce the Grating Interferometer Phase Ratio (GPR) method, which bypasses absolute displacement by leveraging a dimensionless phase ratio between a thermally stable reference and a temperature-controlled test grating under synchronous motion. This ratiometric architecture intrinsically decouples cosine, grating scale, and boundary truncation errors while effectively suppressing the influence of periodic nonlinearities. Validation on single-crystal silicon over 30–90 °C yields an average CTE of 2.731×10-6 °C-1 deviating <0.3% from laser absolute methods. Notably, despite a compact 2-millimeter scan, the method achieves an uncertainty of 3×10-9 °C-1. This approach establishes a robust paradigm for ultra-precision thermomechanical characterization, overcoming the physical limits of traditional displacement metrology.
- 11 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessGrating Interferometer Phase Ratio Method for Coefficient-of-Thermal-Expansion Measurement Without Absolute Length Determination
In the era of Atomic and Close-to-Atomic Scale Manufacturing (ACSM), the dimensional stability of ultra-precision systems approaches physical limits, rendering precise measurement of the coefficient of thermal expansion (CTE) critical. Yet, existing methods remain fundamentally constrained by reliance on absolute length measurements susceptible to environmental drift. Here, we introduce the Grating Interferometer Phase Ratio (GPR) method, which bypasses absolute displacement by leveraging a dimensionless phase ratio between a thermally stable reference and a temperature-controlled test grating under synchronous motion. This ratiometric architecture intrinsically decouples cosine, grating scale, and boundary truncation errors while effectively suppressing the influence of periodic nonlinearities. Validation on single-crystal silicon over 30–90 °C yields an average CTE of 2.731×10-6 °C-1 deviating <0.3% from laser absolute methods. Notably, despite a compact 2-millimeter scan, the method achieves an uncertainty of 3×10-9 °C-1. This approach establishes a robust paradigm for ultra-precision thermomechanical characterization, overcoming the physical limits of traditional displacement metrology.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
A Novel Grating-Interferometric Comparator for Calibrating Baseline Errors of Linear Encoders
Accurate nanoscale calibration of linear encoders is essential for precision manufacturing and inspection. The conventional calibration method uses laser interferometric comparators, but these are susceptible to environmental disturbances and uncertainties in air refractive index compensation, making it challenging to achieve both operational convenience and high-accuracy traceability. To address this problem, a novel grating interferometric comparator based on chromium atomic lithography (CAL) gratings is proposed. Using the grating pitch as the reference, this comparator eliminates refractive index corrections, thereby enhancing robustness and ease of use. The grating pitch is determined by the 7S ${}_{3}\!\to ^{7}$ P4 Cr atomic transition frequency, which is directly traceable to the SI with a relative standard uncertainty of $3.7\times 10$ –8. To validate the performance of the proposed comparator, a dual traceability chain comparison system was established, integrating a CAL grating interferometer (CGI) and a stabilized laser interferometer (SLI) for synchronous calibration of linear encoder baseline errors. Experiments demonstrated that the two calibration methods showed good agreement within a travel range of 3 mm, with a maximum deviation of 1.9 nm. Furthermore, the CGI exhibited smaller standard deviations and superior repeatability. The expanded uncertainty of the novel comparator is $U$ ( ${k} =2$ ) = 2.7 nm $+{\,}8.6\times 10^{\mathrm {-8 }}$ L, where $L$ is in meters. This study provides a traceable and interference-resilient calibration solution for linear encoders, offering strong potential for industrial nanometrology.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
A Novel Grating-Interferometric Comparator for Calibrating Baseline Errors of Linear Encoders
Accurate nanoscale calibration of linear encoders is essential for precision manufacturing and inspection. The conventional calibration method uses laser interferometric comparators, but these are susceptible to environmental disturbances and uncertainties in air refractive index compensation, making it challenging to achieve both operational convenience and high-accuracy traceability. To address this problem, a novel grating interferometric comparator based on chromium atomic lithography (CAL) gratings is proposed. Using the grating pitch as the reference, this comparator eliminates refractive index corrections, thereby enhancing robustness and ease of use. The grating pitch is determined by the 7S ${}_{3}\!\to ^{7}$ P4 Cr atomic transition frequency, which is directly traceable to the SI with a relative standard uncertainty of $3.7\times 10$ –8. To validate the performance of the proposed comparator, a dual traceability chain comparison system was established, integrating a CAL grating interferometer (CGI) and a stabilized laser interferometer (SLI) for synchronous calibration of linear encoder baseline errors. Experiments demonstrated that the two calibration methods showed good agreement within a travel range of 3 mm, with a maximum deviation of 1.9 nm. Furthermore, the CGI exhibited smaller standard deviations and superior repeatability. The expanded uncertainty of the novel comparator is $U$ ( ${k} =2$ ) = 2.7 nm $+{\,}8.6\times 10^{\mathrm {-8 }}$ L, where $L$ is in meters. This study provides a traceable and interference-resilient calibration solution for linear encoders, offering strong potential for industrial nanometrology.
- 31 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
A Novel On-Site Primary Accelerometer Calibration Method Based on Homodyne Self-Traceable Grating Interferometer
As a key component in motion state sensing, the accuracy of accelerometers directly affect the performance and safety of their systems. However, their sensitivity can influenced due to various factors during operation, necessitating both pre-deployment and periodic calibration. Traditional primary calibration methods rely on laser interferometers, yet their trueness and stability are compromised by environmental disturbances affecting the laser wavelength, making on-site traceability challenging. Addressing these issues, this study combines a Cr self-traceable grating with a homodyne littrow grating interferometer and primary vibration calibration technique. Leveraging the high line density, stability, and traceability of the self-traceable grating, it achieves high accuracy and on-site traceable calibration. In experiments, the effectiveness of this calibration system was validated using commercial accelerometers, achieving a measurement uncertainty of 0.25%. This calibration technique not only enhances the accuracy and environmental adaptability of accelerometer calibration but also addresses the critical issue of on-site traceability, representing the future direction of in-field accelerometer calibration.
- 31 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
A Novel On-Site Primary Accelerometer Calibration Method Based on Homodyne Self-Traceable Grating Interferometer
As a key component in motion state sensing, the accuracy of accelerometers directly affect the performance and safety of their systems. However, their sensitivity can influenced due to various factors during operation, necessitating both pre-deployment and periodic calibration. Traditional primary calibration methods rely on laser interferometers, yet their trueness and stability are compromised by environmental disturbances affecting the laser wavelength, making on-site traceability challenging. Addressing these issues, this study combines a Cr self-traceable grating with a homodyne littrow grating interferometer and primary vibration calibration technique. Leveraging the high line density, stability, and traceability of the self-traceable grating, it achieves high accuracy and on-site traceable calibration. In experiments, the effectiveness of this calibration system was validated using commercial accelerometers, achieving a measurement uncertainty of 0.25%. This calibration technique not only enhances the accuracy and environmental adaptability of accelerometer calibration but also addresses the critical issue of on-site traceability, representing the future direction of in-field accelerometer calibration.
- Open Access
- 10 September 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (12) , 125009
Shortened and simplified traceability chain for dimensional metrology based on self-traceable standards
Nanoscale measurement is an essential task of nanomanufacturing, and measurement traceability is a fundamental aspect of nanoscale measurement. High-precision nanoscale measurement instruments (e.g. atomic force microscopes (AFM) and scanning electron microscopes (SEM)) need to be calibrated by traceable standards to ensure their accuracy and reliability. However, due to the suboptimal accuracy, uniformity, and consistency of existing standards, they need to be calibrated by metrological instruments traceable to primary length standards (e.g. physical wavelength standards) before use. This results in a long traceability chain that leads to error accumulation and significantly reduces calibration efficiency. This paper proposes a novel shortened and simplified traceability chain, where the physical wavelength standard corresponding to the 7S3 → 7P4° transition frequency of chromium atoms is materialized into self-traceable gratings using the atom lithography technology. The self-traceable gratings can then be directly applied for calibrating measurement instruments. To verify this approach, the self-traceable gratings are calibrated using a metrological AFM of the Physikalisch-Technische Bundesanstalt. Measurement results confirmed the feasibility of the approach. Particularly, our results show that the self-traceable gratings have excellent uniformity over different measurement areas and consistency over different samples, both at 0.001 nm level. Finally, the application of the self-traceable gratings for the calibrations of a commercial AFM and SEM is demonstrated. The new traceability chain significantly simplifies the calibration process, providing a more reliable and higher efficient calibration approach for advanced nanomanufacturing than that of the state-of-the-art.
- 10 September 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (12) , 125009
Open AccessShortened and simplified traceability chain for dimensional metrology based on self-traceable standards
Nanoscale measurement is an essential task of nanomanufacturing, and measurement traceability is a fundamental aspect of nanoscale measurement. High-precision nanoscale measurement instruments (e.g. atomic force microscopes (AFM) and scanning electron microscopes (SEM)) need to be calibrated by traceable standards to ensure their accuracy and reliability. However, due to the suboptimal accuracy, uniformity, and consistency of existing standards, they need to be calibrated by metrological instruments traceable to primary length standards (e.g. physical wavelength standards) before use. This results in a long traceability chain that leads to error accumulation and significantly reduces calibration efficiency. This paper proposes a novel shortened and simplified traceability chain, where the physical wavelength standard corresponding to the 7S3 → 7P4° transition frequency of chromium atoms is materialized into self-traceable gratings using the atom lithography technology. The self-traceable gratings can then be directly applied for calibrating measurement instruments. To verify this approach, the self-traceable gratings are calibrated using a metrological AFM of the Physikalisch-Technische Bundesanstalt. Measurement results confirmed the feasibility of the approach. Particularly, our results show that the self-traceable gratings have excellent uniformity over different measurement areas and consistency over different samples, both at 0.001 nm level. Finally, the application of the self-traceable gratings for the calibrations of a commercial AFM and SEM is demonstrated. The new traceability chain significantly simplifies the calibration process, providing a more reliable and higher efficient calibration approach for advanced nanomanufacturing than that of the state-of-the-art.