Takahiro Sato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takahiro Sato has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Daisuke Kudo
Division of Rehabilitation Medicine, Akita University Hospital, 44-2, Hiroomote Hasunuma, Akita 010-8543, Japan
3 shared publications - Naohisa Miyakoshi
Department of Orthopaedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Japan
3 shared publications - Ryota Kimura
Department of Orthopedic Surgery, Akita University Graduate School of Medicine, Akita, Japan
3 shared publications - Takehiro Iwami
Department of Systems Design Engineering, Faculty of Engineering Science, Akita University Graduate School of Engineering Science, 1-1 Tegata Gakuen-cho, Akita 010-8502, Japan
3 shared publications - Yuji Kasukawa
Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Japan
3 shared publications Naohisa Miyakoshi
Department of Orthopedic Surgery, Akita University, Akita, Japan
2 shared publications
Latest Publications
- Open Access
Effects of Gait Rehabilitation Robot Combined with Electrical Stimulation on Spinal Cord Injury Patients’ Blood Pressure
Background: Orthostatic hypotension can occur during acute spinal cord injury (SCI) and subsequently persist. We investigated whether a gait rehabilitation robot combined with functional electrical stimulation (FES) stabilizes hemodynamics during orthostatic stress in SCI. Methods: Six intermediate-phase SCI patients (five males and one female; mean age: 49.5 years; four with quadriplegia and two with paraplegia) participated. The participants underwent robotic training (RT), with a gait rehabilitation robot combined with FES, and tilt table training (TT). Hemodynamics were monitored using a laser Doppler flowmeter for the earlobe blood flow (EBF) and non-invasive blood pressure measurements. The EBF over time and the resting and exercise blood pressures were compared between each session. Adverse events were also evaluated. Results: The EBF change decreased in TT but increased in RT at the 0.5-min slope (p = 0.03). Similarly, the pulse rate change increased in TT but decreased in RT at the 1-min slope (p = 0.03). Systolic and mean blood pressures were slightly higher in RT than in TT but not significantly (p = 0.35; 0.40). No adverse events occurred in RT, but two TT sessions were incomplete due to dizziness. Conclusions: RT with FES can reduce symptoms during orthostatic stress in intermediate-phase SCI. Future studies require a larger number of cases to generalize this study.
Open AccessEffects of Gait Rehabilitation Robot Combined with Electrical Stimulation on Spinal Cord Injury Patients’ Blood Pressure
Background: Orthostatic hypotension can occur during acute spinal cord injury (SCI) and subsequently persist. We investigated whether a gait rehabilitation robot combined with functional electrical stimulation (FES) stabilizes hemodynamics during orthostatic stress in SCI. Methods: Six intermediate-phase SCI patients (five males and one female; mean age: 49.5 years; four with quadriplegia and two with paraplegia) participated. The participants underwent robotic training (RT), with a gait rehabilitation robot combined with FES, and tilt table training (TT). Hemodynamics were monitored using a laser Doppler flowmeter for the earlobe blood flow (EBF) and non-invasive blood pressure measurements. The EBF over time and the resting and exercise blood pressures were compared between each session. Adverse events were also evaluated. Results: The EBF change decreased in TT but increased in RT at the 0.5-min slope (p = 0.03). Similarly, the pulse rate change increased in TT but decreased in RT at the 1-min slope (p = 0.03). Systolic and mean blood pressures were slightly higher in RT than in TT but not significantly (p = 0.35; 0.40). No adverse events occurred in RT, but two TT sessions were incomplete due to dizziness. Conclusions: RT with FES can reduce symptoms during orthostatic stress in intermediate-phase SCI. Future studies require a larger number of cases to generalize this study.
- Open Access
- 1 January 2025
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2025 (1) , 4789432
Effectiveness of Peripheral Nerve Block for Early Active Exercise: Three Cases of Pyogenic Flexor Tenosynovitis
To prevent limitations in the range of motion after hand surgery, it is crucial to minimize scar tissue formation and adhesions. Thus, it is important to initiate active hand exercises during the early postoperative period. Peripheral nerve blocks (PNBs) may be employed for active hand exercises as they minimize postoperative pain. We reported three cases of pyogenic flexor tendonitis in which PNB was administered postoperatively, and changes in the range of motion were observed. In all cases, a pulp–palmar distance (PPD) of 1 mm was achieved within 1 week after surgery under PNB, and all cases were evaluated as “good” in Flynn’s functional evaluation at the last observation. However, PPD worsened at 3 weeks postoperatively, and all patients exhibited limited proximal interphalangeal joint extension at the final observation. Although our method effectively improved the flexion range of motion, additional measures should be taken to improve the extension range of motion.
- 1 January 2025
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2025 (1) , 4789432
Open AccessEffectiveness of Peripheral Nerve Block for Early Active Exercise: Three Cases of Pyogenic Flexor Tenosynovitis
To prevent limitations in the range of motion after hand surgery, it is crucial to minimize scar tissue formation and adhesions. Thus, it is important to initiate active hand exercises during the early postoperative period. Peripheral nerve blocks (PNBs) may be employed for active hand exercises as they minimize postoperative pain. We reported three cases of pyogenic flexor tendonitis in which PNB was administered postoperatively, and changes in the range of motion were observed. In all cases, a pulp–palmar distance (PPD) of 1 mm was achieved within 1 week after surgery under PNB, and all cases were evaluated as “good” in Flynn’s functional evaluation at the last observation. However, PPD worsened at 3 weeks postoperatively, and all patients exhibited limited proximal interphalangeal joint extension at the final observation. Although our method effectively improved the flexion range of motion, additional measures should be taken to improve the extension range of motion.
- Open Access
- 13 October 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (10) , 621
Automatic Assist Level Adjustment Function of a Gait Exercise Rehabilitation Robot with Functional Electrical Stimulation for Spinal Cord Injury: Insights from Clinical Trials
This study aimed to identify whether the combined use of functional electrical stimulation (FES) reduces the motor torque of a gait exercise rehabilitation robot in spinal cord injury (SCI) and to verify the effectiveness of the developed automatic assist level adjustment in people with paraplegia. Acute and chronic SCI patients (1 case each) performed 10 min of gait exercises with and without FES using a rehabilitation robot. Reinforcement learning was used to adjust the assist level automatically. The maximum torque values and assist levels for each of the ten walking cycles when walking became steady were averaged and compared with and without FES. The motor’s output torque and the assist level were measured as outcomes. The assist level adjustment allowed both the motor torque and assist level to decrease gradually to a steady state. The motor torque and the assist levels were significantly lower with the FES than without the FES under steady conditions in both cases. No adverse events were reported. The combined use of FES attenuated the motor torque of a gait exercise rehabilitation robot for SCI. Automatic assistive level adjustment is also useful for spinal cord injuries.
- 13 October 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (10) , 621
Open AccessAutomatic Assist Level Adjustment Function of a Gait Exercise Rehabilitation Robot with Functional Electrical Stimulation for Spinal Cord Injury: Insights from Clinical Trials
This study aimed to identify whether the combined use of functional electrical stimulation (FES) reduces the motor torque of a gait exercise rehabilitation robot in spinal cord injury (SCI) and to verify the effectiveness of the developed automatic assist level adjustment in people with paraplegia. Acute and chronic SCI patients (1 case each) performed 10 min of gait exercises with and without FES using a rehabilitation robot. Reinforcement learning was used to adjust the assist level automatically. The maximum torque values and assist levels for each of the ten walking cycles when walking became steady were averaged and compared with and without FES. The motor’s output torque and the assist level were measured as outcomes. The assist level adjustment allowed both the motor torque and assist level to decrease gradually to a steady state. The motor torque and the assist levels were significantly lower with the FES than without the FES under steady conditions in both cases. No adverse events were reported. The combined use of FES attenuated the motor torque of a gait exercise rehabilitation robot for SCI. Automatic assistive level adjustment is also useful for spinal cord injuries.
- Open Access
- 12 September 2024
- Published by MDPI AG in Preprints.org
Automatic Assist Level Adjustment Function of a Gait Exercise Rehabilitation Robot with Functional Electrical Stimulation for Spinal Cord Injury
This study aimed to identify whether the combined use of functional electrical stimulation (FES) reduces the motor torque of a gait exercise rehabilitation robot in spinal cord injury (SCI) and to verify the effectiveness of the developed automatic assist level adjustment in people with paraplegia. Acute and chronic SCI patients (1 case each) performed 10 min of gait exercises with and without FES using a rehabilitation robot. Reinforcement learning was used to adjust the assist level automatically. The maximum torque values and assist levels for each of the ten walking cycles when walking became steady were averaged and compared with and without FES. The motor's output torque and the assist level were measured as outcomes. The assist level adjustment allowed both the motor torque and assist level to decrease gradually to a steady state. The motor torque and the assist levels were significantly lower with the FES than without the FES under steady conditions in both cases. No adverse events were reported. The combined use of FES attenuated the motor torque of a gait exercise rehabilitation robot for SCI. Automatic assistive level adjustment is also useful for spinal cord injuries.
- 12 September 2024
- Published by MDPI AG in Preprints.org
Open AccessAutomatic Assist Level Adjustment Function of a Gait Exercise Rehabilitation Robot with Functional Electrical Stimulation for Spinal Cord Injury
This study aimed to identify whether the combined use of functional electrical stimulation (FES) reduces the motor torque of a gait exercise rehabilitation robot in spinal cord injury (SCI) and to verify the effectiveness of the developed automatic assist level adjustment in people with paraplegia. Acute and chronic SCI patients (1 case each) performed 10 min of gait exercises with and without FES using a rehabilitation robot. Reinforcement learning was used to adjust the assist level automatically. The maximum torque values and assist levels for each of the ten walking cycles when walking became steady were averaged and compared with and without FES. The motor's output torque and the assist level were measured as outcomes. The assist level adjustment allowed both the motor torque and assist level to decrease gradually to a steady state. The motor torque and the assist levels were significantly lower with the FES than without the FES under steady conditions in both cases. No adverse events were reported. The combined use of FES attenuated the motor torque of a gait exercise rehabilitation robot for SCI. Automatic assistive level adjustment is also useful for spinal cord injuries.
- Open Access
- 21 September 2022
- Published by Bentham Science Publishers Ltd. in The Open Orthopaedics Journal
- Vol. 16 (1)
Lumbar Solitary Osteochondroma with Lower Extremity Weakness: A Case Report
Background: Osteochondroma is the most common benign bone tumor. However, osteochondroma of the spine is relatively rare, accounting for only 4% to 7% of primary benign spinal tumors and less than 3% of all osteochondromas. Furthermore, symptomatic osteochondroma in the lumbar spine is much rarer. We herein describe a patient who was diagnosed with a lumbar solitary osteochondroma causing neurological symptoms of the lower extremities. The patient successfully underwent surgical removal of the lesion. Case Presentation: A 79-year-old man presented with a 3-year history of difficulty walking and gradual development of numbness in his left upper extremity, which further exacerbated his difficulty walking. Magnetic resonance imaging and computed tomography revealed spinal stenosis at C3/4, L4/5, and L5/S1 and an osseous solitary lesion. We performed a single-stage operation of both the cervical and lumbar spine. The osseous solitary lesion at L5/S1 was removed, and the pathological diagnosis was osteochondroma. After the operation, the patient’s upper extremity numbness and walking ability were improved. Conclusions: We experienced a rare case of a neurologically symptomatic solitary osteochondroma in the lumbar spinal canal. Moreover, this lesion was found at the same time as cervical spondylosis causing numbness. Therefore, we must perform careful examinations and thoroughly evaluate imaging and postoperative pathological findings.
- 21 September 2022
- Published by Bentham Science Publishers Ltd. in The Open Orthopaedics Journal
- Vol. 16 (1)
Open AccessLumbar Solitary Osteochondroma with Lower Extremity Weakness: A Case Report
Background: Osteochondroma is the most common benign bone tumor. However, osteochondroma of the spine is relatively rare, accounting for only 4% to 7% of primary benign spinal tumors and less than 3% of all osteochondromas. Furthermore, symptomatic osteochondroma in the lumbar spine is much rarer. We herein describe a patient who was diagnosed with a lumbar solitary osteochondroma causing neurological symptoms of the lower extremities. The patient successfully underwent surgical removal of the lesion. Case Presentation: A 79-year-old man presented with a 3-year history of difficulty walking and gradual development of numbness in his left upper extremity, which further exacerbated his difficulty walking. Magnetic resonance imaging and computed tomography revealed spinal stenosis at C3/4, L4/5, and L5/S1 and an osseous solitary lesion. We performed a single-stage operation of both the cervical and lumbar spine. The osseous solitary lesion at L5/S1 was removed, and the pathological diagnosis was osteochondroma. After the operation, the patient’s upper extremity numbness and walking ability were improved. Conclusions: We experienced a rare case of a neurologically symptomatic solitary osteochondroma in the lumbar spinal canal. Moreover, this lesion was found at the same time as cervical spondylosis causing numbness. Therefore, we must perform careful examinations and thoroughly evaluate imaging and postoperative pathological findings.