Milenko Roš
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Milenko Roš has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Aleksandra Lobnik
1 shared publication- Aleksandra Lobnik
University of Maribor
1 shared publication - Andreja Drolc
National Institute of Chemistry
1 shared publication Hakim El Khiar
1 shared publicationJolanda Rihter Pikl
1 shared publicationM. Bauman
Em.TRONIC , SI-2000, Maribor, Slovenia ; University of Maribor, Faculty of Mechanical Engineering, Centre of Sensor Technology , SI-2000, Maribor, Slovenia
1 shared publication
Latest Publications
- Open Access
- 8 September 2024
- Published by Elsevier in Cleaner Engineering and Technology
- Vol. 22
Microfibres and coliforms determination and removal from wastewater treatment effluent
- 8 September 2024
- Published by Elsevier in Cleaner Engineering and Technology
- Vol. 22
Open AccessMicrofibres and coliforms determination and removal from wastewater treatment effluent
- 25 January 2011
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 33 (1) , 31-36
Reduction of Biocide-Polluted Wastewater Using O3and H2O2/O3Oxidation Processes
The objective of the presented study was to test various oxidation processes with the aim being to reduce the concentration and toxicity of biocide wastewater from a Slovenian phytopharmaceutical factory. Laboratory-scale experiments employing two AOP processes – ozonation (O3) and peroxone (H2O2/O3) – were applied to reduce the concentration of the active components involved, i.e., methylisothiazolone (MI), chloromethylisothiazolone (CMI) and dichloromethylisothiazolone (DCMI). The reduction of the biocide wastewater load for the performed oxidation processes was evaluated using ecological parameters. The H2O2/O3 oxidation procedure using an O3 flow rate of 1g/L h, at a pH value of 10 and with the addition of 5 ml of H2O2 (0.3 M) proved to be the most effective treatment. The toxicity of the biocide-load wastewater with an initial EC50 = 0.38%, decreased to EC50 (24h) >100% and EC50 (48h) = 76%.
- 25 January 2011
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 33 (1) , 31-36
Reduction of Biocide-Polluted Wastewater Using O3and H2O2/O3Oxidation Processes
The objective of the presented study was to test various oxidation processes with the aim being to reduce the concentration and toxicity of biocide wastewater from a Slovenian phytopharmaceutical factory. Laboratory-scale experiments employing two AOP processes – ozonation (O3) and peroxone (H2O2/O3) – were applied to reduce the concentration of the active components involved, i.e., methylisothiazolone (MI), chloromethylisothiazolone (CMI) and dichloromethylisothiazolone (DCMI). The reduction of the biocide wastewater load for the performed oxidation processes was evaluated using ecological parameters. The H2O2/O3 oxidation procedure using an O3 flow rate of 1g/L h, at a pH value of 10 and with the addition of 5 ml of H2O2 (0.3 M) proved to be the most effective treatment. The toxicity of the biocide-load wastewater with an initial EC50 = 0.38%, decreased to EC50 (24h) >100% and EC50 (48h) = 76%.
- 22 October 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (5) , 1243-1250
Establishment of traceability of ammonium nitrogen determination in wastewater
A case study is presented for the establishment of traceability for ammonium nitrogen determination in wastewater in a routine laboratory in order to fulfil the requirements of ISO/IEC standard 17025. The necessary relevant information was obtained from the method validation data, the quality control data and equipment calibration certificates. The method of measurement is described together with the measurement equation, selected traceable reference standards and the associated measurement uncertainty. The major sources of uncertainty of the result of measurement were identified and the combined uncertainty was calculated. Identification of the main uncertainty sources represents the basis for target operations for reducing the measurement uncertainty of this determination.
- 22 October 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (5) , 1243-1250
Establishment of traceability of ammonium nitrogen determination in wastewater
A case study is presented for the establishment of traceability for ammonium nitrogen determination in wastewater in a routine laboratory in order to fulfil the requirements of ISO/IEC standard 17025. The necessary relevant information was obtained from the method validation data, the quality control data and equipment calibration certificates. The method of measurement is described together with the measurement equation, selected traceable reference standards and the associated measurement uncertainty. The major sources of uncertainty of the result of measurement were identified and the combined uncertainty was calculated. Identification of the main uncertainty sources represents the basis for target operations for reducing the measurement uncertainty of this determination.