RKR. Kishimori

R. Kishimori

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


R. Kishimori has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons

    by R. Kishimori, M. Cufari, E. Z. L. Zhong-Johnson, B. I. Buschmann, A. J. Sinskey, T. M. Johnson, N. Vanderloo, A. DeVault, B. C. Foo, J. Vargas, et al.

    Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.


  • Open Access

    Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

    by B. L. Reichelt, R. Kishimori, Y. Lawrence, C. W. Wink, M. Gatu Johnson, T. M. Johnson, P. J. Adrian, K. L. Baker, D. T. Casey, D. S. Clark, et al.

    The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.


  • Open Access

    Intrinsic fluence non-uniformity in D3He backlit proton radiography

    by T. M. Johnson, J. Shan, R. Kishimori, M. J. Cufari, P. J. Adrian, B. Buschmann, C. W. Chang, S. G. Dannhoff, A. DeVault, T. E. Evans, et al.

    Proton radiography is an essential diagnostic for studying magnetic fields in high energy density physics experiments. Protons are born in a fusion implosion, traverse the plasma, and are detected on CR-39 solid state nuclear track detectors. Here, it is shown that there is an intrinsic non-uniformity in ∼15 MeV D3He proton radiography data. The increasing angle between the proton trajectory and the center of the detector results in the proton traveling through more detector stack material. As the protons travel through more material and lose energy, the proton energy spectrum gets wider. Protons at the lower end of the spectrum can therefore be lost. The nominal filtering results in protons being ranged out at large angles, causing the intrinsic non-uniformity. This angular effect is confirmed with both OMEGA experiments and Geant4 simulations. It is found that reducing the filtering between the pieces of CR-39 in the detector stack mitigates this effect. Results from accelerator experiments show that this reduced filtering does not impact the detection efficiency of the CR-39. Accounting for this intrinsic fluence non-uniformity is essential for magnetic field reconstruction techniques using proton radiographs.