Oliver Limberger
Research Subjects
Oliver Limberger has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Fries
Departamento de Geología, Minas e Ingeniería Civil (DGMIC), Universidad Técnica Particular de Loja, San Cayetano Alto s/n, Loja 11-01-608, Ecuador
2 shared publications - Charuta Murkute
Department of Atmospheric Processes, Brandenburg University of Technology Cottbus-Senftenberg, Burger Chaussee 2, 03046 Cottbus, Germany
2 shared publications - Franz Pucha-Cofrep
Hydrology and Climatology Working Group, Departamento de Ingeniería Civil, Universidad Técnica Particular de Loja, San Cayetano Alto, C. París, Loja 110107, Ecuador
2 shared publications - Galo Carrillo-Rojas
Departamento de Recursos Hídricos y Ciencias Ambientales, Universidad de Cuenca, Cuenca, Ecuador
2 shared publications - Jörg Bendix
Department of Geography Philipps‐Universität Marburg Marburg Germany
2 shared publications - Jürgen Homeier
Faculty of Resource Management, HAWK University of Applied Sciences and Arts, 37075 Göttingen, Germany
2 shared publications
Latest Publications
- Open Access
Turbulent Energy and Carbon Fluxes in an Andean Montane Forest—Energy Balance and Heat Storage
High mountain rainforests are vital in the global energy and carbon cycle. Understanding the exchange of energy and carbon plays an important role in reflecting responses to climate change. In this study, an eddy covariance (EC) measurement system installed in the high Andean Mountains of southern Ecuador was used. As EC measurements are affected by heterogeneous topography and the vegetation height, the main objective was to estimate the effect of the sloped terrain and the forest on the turbulent energy and carbon fluxes considering the energy balance closure (EBC) and the heat storage. The results showed that the performance of the EBC was generally good and estimated it to be 79.5%. This could be improved when the heat storage effect was considered. Based on the variability of the residuals in the diel, modifications in the imbalances were highlighted. Particularly, during daytime, the residuals were largest (56.9 W/m2 on average), with a clear overestimation. At nighttime, mean imbalances were rather weak (6.5 W/m2) and mostly positive while strongest underestimations developed in the transition period to morning hours (down to −100 W/m2). With respect to the Monin–Obukhov stability parameter ((z − d)/L) and the friction velocity (u*), it was revealed that the largest overestimations evolved in weak unstable and very stable conditions associated with large u* values. In contrast, underestimation was related to very unstable conditions. The estimated carbon fluxes were independently modelled with a non-linear regression using a light-response relationship and reached a good performance value (R2 = 0.51). All fluxes were additionally examined in the annual course to estimate whether both the energy and carbon fluxes resembled the microclimatological conditions of the study site. This unique study demonstrated that EC measurements provide valuable insights into land-surface–atmosphere interactions and contribute to our understanding of energy and carbon exchanges. Moreover, the flux data provide an important basis to validate coupled atmosphere ecosystem models.
Open AccessTurbulent Energy and Carbon Fluxes in an Andean Montane Forest—Energy Balance and Heat Storage
High mountain rainforests are vital in the global energy and carbon cycle. Understanding the exchange of energy and carbon plays an important role in reflecting responses to climate change. In this study, an eddy covariance (EC) measurement system installed in the high Andean Mountains of southern Ecuador was used. As EC measurements are affected by heterogeneous topography and the vegetation height, the main objective was to estimate the effect of the sloped terrain and the forest on the turbulent energy and carbon fluxes considering the energy balance closure (EBC) and the heat storage. The results showed that the performance of the EBC was generally good and estimated it to be 79.5%. This could be improved when the heat storage effect was considered. Based on the variability of the residuals in the diel, modifications in the imbalances were highlighted. Particularly, during daytime, the residuals were largest (56.9 W/m2 on average), with a clear overestimation. At nighttime, mean imbalances were rather weak (6.5 W/m2) and mostly positive while strongest underestimations developed in the transition period to morning hours (down to −100 W/m2). With respect to the Monin–Obukhov stability parameter ((z − d)/L) and the friction velocity (u*), it was revealed that the largest overestimations evolved in weak unstable and very stable conditions associated with large u* values. In contrast, underestimation was related to very unstable conditions. The estimated carbon fluxes were independently modelled with a non-linear regression using a light-response relationship and reached a good performance value (R2 = 0.51). All fluxes were additionally examined in the annual course to estimate whether both the energy and carbon fluxes resembled the microclimatological conditions of the study site. This unique study demonstrated that EC measurements provide valuable insights into land-surface–atmosphere interactions and contribute to our understanding of energy and carbon exchanges. Moreover, the flux data provide an important basis to validate coupled atmosphere ecosystem models.
- Open Access
- 13 September 2024
- Published by MDPI AG in Preprints.org
Turbulent Energy and Carbon Fluxes in an Andean Montane Forest - Energy Balance and Heat Storage
High mountain rainforests are vital in the global energy and carbon cycle. Understanding the exchange of energy and carbon plays an important role to reflect responses to climate change. In this study, an eddy-covariance (EC) measurement system installed in the high Andean Mountains of South Ecuador was used. As EC measurements are affected by heterogeneous topography and vegetation height, the main objective was to estimate the effect of the sloped terrain and the forest on the turbulent energy and carbon fluxes considering the energy balance closure (EBC) and the heat storage. The results showed that the performance of the EBC was generally good and estimated to be 79.5%. This could be improved when the heat storage effect was considered. Based on the variability of the residuals in the diel modifications in the imbalances were highlighted. Particularly, during daytime residuals were largest (56.9 W/m² on average) with a clear overestimation. At nighttime mean imbalances were rather weak (6.5 W/m²) and mostly positive, while strongest underestimations developed in the transition period to morning hours (down to -100 W/m²). With respect to the Monin-Obukhov stability parameter ((z-d)/L) and the friction velocity (u*) it was revealed that largest overestimations evolved in weak unstable and very stable conditions associated with large u* values. In contrast, underestimation was related to very unstable conditions. The estimated carbon fluxes were independently modelled with a non-linear regression using a light-response relationship and reached a good performance (R²=0.52). All fluxes were additionally examined in the annual course to estimate whether both, energy and carbon fluxes, resembled the microclimatological conditions of the study site. This unique study demonstrated that EC measurements provide valuable insights into land surface -atmosphere interactions and contribute to our understanding of energy and carbon exchanges. Moreover, the flux data provide an important basis to validate coupled atmosphere ecosystem models.
- 13 September 2024
- Published by MDPI AG in Preprints.org
Open AccessTurbulent Energy and Carbon Fluxes in an Andean Montane Forest - Energy Balance and Heat Storage
High mountain rainforests are vital in the global energy and carbon cycle. Understanding the exchange of energy and carbon plays an important role to reflect responses to climate change. In this study, an eddy-covariance (EC) measurement system installed in the high Andean Mountains of South Ecuador was used. As EC measurements are affected by heterogeneous topography and vegetation height, the main objective was to estimate the effect of the sloped terrain and the forest on the turbulent energy and carbon fluxes considering the energy balance closure (EBC) and the heat storage. The results showed that the performance of the EBC was generally good and estimated to be 79.5%. This could be improved when the heat storage effect was considered. Based on the variability of the residuals in the diel modifications in the imbalances were highlighted. Particularly, during daytime residuals were largest (56.9 W/m² on average) with a clear overestimation. At nighttime mean imbalances were rather weak (6.5 W/m²) and mostly positive, while strongest underestimations developed in the transition period to morning hours (down to -100 W/m²). With respect to the Monin-Obukhov stability parameter ((z-d)/L) and the friction velocity (u*) it was revealed that largest overestimations evolved in weak unstable and very stable conditions associated with large u* values. In contrast, underestimation was related to very unstable conditions. The estimated carbon fluxes were independently modelled with a non-linear regression using a light-response relationship and reached a good performance (R²=0.52). All fluxes were additionally examined in the annual course to estimate whether both, energy and carbon fluxes, resembled the microclimatological conditions of the study site. This unique study demonstrated that EC measurements provide valuable insights into land surface -atmosphere interactions and contribute to our understanding of energy and carbon exchanges. Moreover, the flux data provide an important basis to validate coupled atmosphere ecosystem models.