Yu Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yu Song has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Guowei Gao
Beijing Key Laboratory of Sensor, Beijing Information Science and Technology University, Beijing 100101, China
2 shared publications - Chao Bian
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Hui Zhang
Beijing Key Laboratory of Sensor, Beijing Information Science & Technology University, Beijing 100101, China
1 shared publication - Jianhua Tong
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Jingfang Hu
Beijing Key Laboratory of Sensor, Beijing Information Science & Technology University, Beijing 100101, China
1 shared publication - Jingfang Hu
Beijing Key Laboratory of Sensor, Beijing Information Science & Technology University, Beijing 100101, China
1 shared publication
Latest Publications
- Open Access
OS-PSO: A Modified Ratio of Exponentially Weighted Averages-Based Optical and SAR Image Registration
Optical and synthetic aperture radar (SAR) images exhibit non-negligible intensity differences due to their unique imaging mechanisms, which makes it difficult for classical SIFT-based algorithms to obtain sufficiently correct correspondences when processing the registration of these two types of images. To tackle this problem, an accurate optical and SAR image registration algorithm based on the SIFT algorithm (OS-PSO) is proposed. First, a modified ratio of exponentially weighted averages (MROEWA) operator is introduced to resolve the sudden dark patches in SAR images, thus generating more consistent gradients between optical and SAR images. Next, we innovatively construct the Harris scale space to replace the traditional difference in the Gaussian (DoG) scale space, identify repeatable key-points by searching for local maxima, and perform localization refinement on the identified key-points to improve their accuracy. Immediately after that, the gradient location orientation histogram (GLOH) method is adopted to construct the feature descriptors. Finally, we propose an enhanced matching method. The transformed relation is obtained in the initial matching stage using the nearest neighbor distance ratio (NNDR) and fast sample consensus (FSC) methods. And the re-matching takes into account the location, scale, and main direction of key-points to increase the number of correctly corresponding points. The proposed OS-PSO algorithm has been implemented on the Gaofen and Sentinel series with excellent results. The superior performance of the designed registration system can also be applied in complex scenarios, including urban, suburban, river, farmland, and lake areas, with more efficiency and accuracy than the state-of-the-art methods based on the WHU-OPT-SAR dataset and the BISTU-OPT-SAR dataset.
Open AccessOS-PSO: A Modified Ratio of Exponentially Weighted Averages-Based Optical and SAR Image Registration
Optical and synthetic aperture radar (SAR) images exhibit non-negligible intensity differences due to their unique imaging mechanisms, which makes it difficult for classical SIFT-based algorithms to obtain sufficiently correct correspondences when processing the registration of these two types of images. To tackle this problem, an accurate optical and SAR image registration algorithm based on the SIFT algorithm (OS-PSO) is proposed. First, a modified ratio of exponentially weighted averages (MROEWA) operator is introduced to resolve the sudden dark patches in SAR images, thus generating more consistent gradients between optical and SAR images. Next, we innovatively construct the Harris scale space to replace the traditional difference in the Gaussian (DoG) scale space, identify repeatable key-points by searching for local maxima, and perform localization refinement on the identified key-points to improve their accuracy. Immediately after that, the gradient location orientation histogram (GLOH) method is adopted to construct the feature descriptors. Finally, we propose an enhanced matching method. The transformed relation is obtained in the initial matching stage using the nearest neighbor distance ratio (NNDR) and fast sample consensus (FSC) methods. And the re-matching takes into account the location, scale, and main direction of key-points to increase the number of correctly corresponding points. The proposed OS-PSO algorithm has been implemented on the Gaofen and Sentinel series with excellent results. The superior performance of the designed registration system can also be applied in complex scenarios, including urban, suburban, river, farmland, and lake areas, with more efficiency and accuracy than the state-of-the-art methods based on the WHU-OPT-SAR dataset and the BISTU-OPT-SAR dataset.
- Open Access
A Novel Electrochemical Sensor Based on Electropolymerized Ion Imprinted PoPD/ERGO Composite for Trace Cd(II) Determination in Water
A novel electrochemical sensor based on electropolymerized ion imprinted poly (o-phenylenediamine) PoPD/electrochemical reduced graphene (ERGO) composite on glass carbon electrode (GCE) was fabricated for selective and sensitive determination of trace Cd(II) in water. ERGO was first deposited on the surface of GCE by electrochemical cyclic voltammetry (CV) scanning to enhance the electron transport activity at electrode surface. The ion imprinted polymer (IIP) of imprinted PoPD was then in situ electropolymerized on ERGO via CV scanning with oPD as functional monomer and Cd(II) ions as template, following removal of the template using electrochemical peroxidation method. The obtained imprinted PoPD/RERGO composites were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray energy spectroscopy (EDS) for the observation of their morphologies and components. The electrochemical behavior of the imprinted PoPD/ERGO/GCE was performed by CV and SWASV. The fabricated sensor of the imprinted PoPD/ERGO/GCE showed a good selectivity toward target Cd(II) ions in the presence of other heavy metal ions. Under the optimized experimental conditions, the sensor exhibited a good linear relationship between SWASV stripping peak values and Cd(II) concentration in the range of 1 to 50 ng/mL, with the limit of detection as 0.13 ng/mL (S/N = 3). The proposed electrochemical sensor of imprinted PoPD/ERGO/GCE was successfully applied for trace Cd(II) determination in real water samples.
Open AccessA Novel Electrochemical Sensor Based on Electropolymerized Ion Imprinted PoPD/ERGO Composite for Trace Cd(II) Determination in Water
A novel electrochemical sensor based on electropolymerized ion imprinted poly (o-phenylenediamine) PoPD/electrochemical reduced graphene (ERGO) composite on glass carbon electrode (GCE) was fabricated for selective and sensitive determination of trace Cd(II) in water. ERGO was first deposited on the surface of GCE by electrochemical cyclic voltammetry (CV) scanning to enhance the electron transport activity at electrode surface. The ion imprinted polymer (IIP) of imprinted PoPD was then in situ electropolymerized on ERGO via CV scanning with oPD as functional monomer and Cd(II) ions as template, following removal of the template using electrochemical peroxidation method. The obtained imprinted PoPD/RERGO composites were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray energy spectroscopy (EDS) for the observation of their morphologies and components. The electrochemical behavior of the imprinted PoPD/ERGO/GCE was performed by CV and SWASV. The fabricated sensor of the imprinted PoPD/ERGO/GCE showed a good selectivity toward target Cd(II) ions in the presence of other heavy metal ions. Under the optimized experimental conditions, the sensor exhibited a good linear relationship between SWASV stripping peak values and Cd(II) concentration in the range of 1 to 50 ng/mL, with the limit of detection as 0.13 ng/mL (S/N = 3). The proposed electrochemical sensor of imprinted PoPD/ERGO/GCE was successfully applied for trace Cd(II) determination in real water samples.
- Open Access
- 13 June 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (6) , 103
The Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium
Cadmium(II) is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr)/l-cysteine/gold electrode to detect trace levels of cadmium (Cd) by differential pulse stripping voltammetry (DPSV). The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/l-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE) and boron-doped diamond (BDD) electrode). The calculated detection limits are 1.15, 0.30, and 1.42 µg/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA·mm−2·µg−1·L for, respectively, the BDD electrode, the GCE, and the Gr/l-cysteine/gold electrode. It was shown that the Gr/l-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.
- 13 June 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (6) , 103
Open AccessThe Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium
Cadmium(II) is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr)/l-cysteine/gold electrode to detect trace levels of cadmium (Cd) by differential pulse stripping voltammetry (DPSV). The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/l-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE) and boron-doped diamond (BDD) electrode). The calculated detection limits are 1.15, 0.30, and 1.42 µg/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA·mm−2·µg−1·L for, respectively, the BDD electrode, the GCE, and the Gr/l-cysteine/gold electrode. It was shown that the Gr/l-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.