XLXiatian Liu

Xiatian Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiatian Liu has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development and evaluation of a transesophageal echocardiography–derived left atrial appendage structure–function coupling index across the atrial fibrillation disease continuum

    by Jianbo Zhu, Chen Ni, Yangnan Ruan, Yanfeng Jiang, Lei Zhu, Yanhua Huang, Zhenzhen Jiang, Xiatian Liu

    Background: Atrial fibrillation (AF) is a progressive disorder associated with atrial remodeling and thromboembolic risk. We developed a transesophageal echocardiography (TEE)-derived left atrial appendage (LAA) structure-function coupling index (LAA-SFCI), defined as LAA volumetric load relative to longitudinal deformation, and assessed its distribution along the AF disease continuum and its potential for risk re-stratification of patients without documented AF. Methods: This single-center, prospective, cross-sectional study included 267 patients undergoing clinically indicated TEE, classified by the 2023 American College of Cardiology/American Heart Association/American College of Clinical Pharmacy/Heart Rhythm Society (ACC/AHA/ACCP/HRS) framework as Stage 1 ( n = 68), Stage 2 ( n = 65), Stage 3a ( n = 66), or Stage 3b ( n = 68). Seven candidate LAA-SFCIs were calculated as the LAA volume index (LAA-VI) divided by a functional measure, and the principal index was selected by ordinal logistic regression using the Akaike information criterion. Discrimination was compared using the DeLong test and internally validated by bootstrapping, and patients without documented AF (Stages 1–2) were stratified by the exploratory cutoff. Results: LAA-VI/LAA-GLS (LAA global longitudinal strain) provided the best model fit and rose across AF stages from 0.33 ± 0.11 to 0.86 ± 0.36 (mL/m 2 )/% ( P < 0.001). In ordinal regression with the log-transformed index, each 1-SD increase remained associated with higher AF stage after adjustment for age, sex, body mass index, left ventricular ejection fraction, and left atrial volume index (odds ratio 11.04, 95% confidence interval 7.17–16.98). For Stage 1–2 versus Stage 3a–3b, its area under the curve (0.904; optimism-corrected 0.900) was significantly higher than those of LAA-VI (0.661) and LAA-GLS (0.824) (both DeLong P < 0.001). Among 133 patients without documented AF, 18 (13.5%) exceeded the cutoff of 0.460 (mL/m 2 )/%; these patients did not differ from the others in left atrial volume index or age. Conclusion: In this cross-sectional study, LAA-VI/LAA-GLS characterized LAA structure–function uncoupling along the AF disease continuum. In patients without documented AF undergoing clinically indicated TEE, it identified a subgroup with an AF-like LAA phenotype not captured by conventional atrial size measures. These findings are hypothesis-generating and require external validation and longitudinal follow-up to determine their prognostic value.

  • Open Access

    Machine learning models combining multimodal ultrasound and clinical factors for predicting ischemic stroke risk in patients with carotid plaques

    by Chen Ni, Yun Li, Yanfeng Jiang, Jianbo Zhu, Junchen Ni, Yangnan Ruan, Shanshan Zhao, Xiatian Liu

  • Multimodality Imaging Findings of Primary Embryonal Rhabdomyosarcoma in the Prostate: A Rare Case Report

    by Yue Wang, Jia‐Hui Chen, Min‐Jun Zhu, Zhen‐Zhen Jiang, Xia‐Tian Liu

    Embryonal rhabdomyosarcoma (ERMS) of the prostate is an extremely rare malignant tumor, which often presents with urinary symptoms. We report a 32‐year‐old male with recurrent urinary retention diagnosed with prostatic ERMS via surgical pathology. This case analyzes the reasons for initial misdiagnosis and details multimodal imaging features on ultrasound (US), contrast‐enhanced ultrasound (CEUS), CT, and MRI. Notably, this report provides the first description of the CEUS enhancement pattern in prostatic ERMS, which may represent a unique imaging characteristic.

  • Open Access

    Diagnostic value of shear wave elastography for diabetic peripheral neuropathy: comparison between junior radiologists and senior radiologists

    by Rong-Li Peng, Yan-Feng Jiang, Hua-Liang Shen, Di-Jia Ni, Ying Zhou, Xia-Tian Liu, Zhen-Zhen Jiang

    Background: Diabetic peripheral neuropathy (DPN) is a prevalent complication of diabetes mellitus, and is often underdiagnosed because of its variable clinical presentation and operator–dependent diagnostic tools. Shear wave elastography (SWE), which quantitatively evaluates tissue stiffness, has the potential to enhance conventional ultrasound by improving diagnostic accuracy and consistency. Nevertheless, a comprehensive analysis examining the extent to which the integration of SWE with conventional ultrasound can enhance the diagnostic performance of radiologists across varying levels of expertise has yet to be performed. Methods: In this study, a total of 458 lower extremities from patients with type 2 diabetes were examined via ultrasound and SWE. Four radiologists (two seniors and two juniors) independently assessed the grayscale ultrasound, SWE, and combined images. Diagnostic performance was compared via receiver operating characteristic (ROC) curves and sensitivity and specificity metrics. Results: SWE measurements revealed significantly greater stiffness of the tibial nerve in the DPN group than in the non-DPN group, with values of 37.30 kPa versus 25.40 kPa ( P < 0.001) and corresponding shear wave velocities of 3.54 m/s versus 2.90 m/s ( P < 0.001). The combined images improved diagnostic accuracy across all readers. Notably, junior radiologists exhibited a substantial improvement in terms of sensitivity (ΔSensitivity = 25.565, 95% CI: 18.477–32.653, P = 0.004). In contrast, for the senior radiologists, neither the sensitivity nor the specificity significantly increased with increasing integration SWE. Conclusion: Combining SWE with conventional ultrasound improves the diagnostic accuracy for DPN and helps reduce performance gaps between junior and senior radiologists. SWE may serve as an effective adjunct to support early detection and consistent evaluation of DPN in clinical practice.


  • Open Access

    An acute pelvic pain in high-altitude tourist: A case report of ruptured ectopic pregnancy with low β-human chorionic gonadotropin

    by Fang Yuan, Zhan-Cheng Cui, Zhen-Zhen Jiang, Xia-Tian Liu

    Rationale: High-altitude acclimatization triggers physiological adaptations – such as increased ventilation, heart rate, and red blood cell production – to improve tissue oxygen delivery. These adaptations may obscure typical signs of hemorrhage, complicating the diagnosis of ruptured ectopic pregnancy in patients with low beta-human chorionic gonadotropin (β-hCG) levels. Patient concerns: A 31-year-old woman developed sudden pelvic pain and mild vaginal bleeding on the third day of high-altitude travel (Qinghai-Tibet Plateau). Diagnoses: Initial evaluation at a local hospital indicated very low β-hCG and no intrauterine gestational sac, leading to a misdiagnosis of biochemical pregnancy. Hemoglobin stability and absence of red blood cell decline, combined with high-altitude physiological changes, further delayed diagnosis. A transvaginal ultrasound later identified a ruptured right fallopian tube ectopic pregnancy, confirmed surgically. Interventions: Surgical confirmation. Outcomes: The case underscores how high-altitude hematologic adaptations (e.g., masked anemia) and low β-hCG levels can mimic benign conditions, complicating timely detection. Lessons: Ectopic pregnancy should remain a differential diagnosis in high-altitude travelers with abdominal pain, even with low β-hCG and stable hematologic parameters. Clinicians should be vigilant for ectopic pregnancy even with low β-hCG and stable hemoglobin in high-altitude travelers, as acclimatization may mask hemorrhagic signs.

  • Open Access

    Diaphragmatic downward excursion as a novel metric for assessing Valsalva maneuver efficacy in patent foramen ovale detection by contrast transthoracic echocardiography

    by Yun Li, Anni Chen, Jianbo Zhu, Lei Zhu, Turgunov Boburjon, Zhenzhen Jiang, Xiatian Liu

    Objective: Contrast transthoracic echocardiography (c-TTE) is widely used for the diagnosis of patent foramen ovale (PFO), where the Valsalva maneuver (VM) serves as the standard provocative maneuver to optimize detection. This study aimed to evaluate diaphragmatic downward excursion (DDE) as a novel c-TTE–based parameter for objectively quantifying VM efficacy, thereby establishing a standardized assessment metric. Methods: We studied 145 patients with high clinical suspicion of PFO-related conditions. All participants underwent both c-TTE and contrast transesophageal echocardiography (c-TEE) examinations. Based on intraoral expiratory pressure exceeding 40 mmHg under c-TTE, patients were divided into adequate Valsalva maneuver (AVM) group ( n = 90) and non-adequate Valsalva maneuver (non-AVM) group ( n = 55). We compared the two groups in terms of DDE at the roof of the right atrium (DDE-RRA) and intracardiac hemodynamic parameters. Results: DDE-RRA was significantly lower in the AVM group than in the non-AVM group (7.3 mm vs. 3.1 mm, P < 0.001). ROC analysis identified 5 mm as the optimal cutoff value for evaluating VM efficacy, with a sensitivity of 77.8%, specificity of 92.7%, and an AUC of 0.90. The kappa test showed good agreement between DDE-RRA and insufflation manometry (kappa = 0.63, P < 0.001). Furthermore, the DeLong test demonstrated that the AUC of DDE-RRA was significantly greater than that of all assessed intracardiac hemodynamic parameters, including mitral and tricuspid peak E and A-wave velocities, as well as mitral and tricuspid velocity time integrals (all P < 0.05). Conclusion: DDE provides a simple and objective method for assessing VM efficacy under c-TTE, showing superior diagnostic performance compared with conventional intracardiac parameters. As this represents an initial attempt, further studies incorporating invasive validation are needed to confirm its clinical value.

  • Open Access

    Development of an explainable machine learning model for 3-year cardiovascular risk prediction in new-onset type 2 diabetes using the TyG index and ultrasound features

    by Zhen-Zhen Jiang, Yan-Feng Jiang, Yue Wang, Ying Zhou, Rong-Li Peng, Cai-Ye Ma, Xia-Tian Liu

    Background: New-onset type 2 diabetes (T2D) is associated with increased cardiovascular risk and requires tailored prevention strategies. Traditional risk factors and assessment tools may not accurately predict cardiovascular disease (CVD) in this population. In our study, we compared different machine learning (ML) methods to predict the 3-year risk of developing CVD in new-onset T2D patients and developed models combining clinical data and ultrasound features for better risk evaluation. Methods: A group of 3,358 hospitalized T2D patients was screened. ML models were developed and evaluated. Feature selection was conducted via SHapley Additive exPlanations (SHAPs) and recursive feature elimination to improve both the model’s performance and its interpretability. The optimal model was subsequently compared with the Framingham Risk Score (FRS). Ultimately, the model was employed for risk stratification. Results: Of the ML models developed, LightGBM, which incorporates six features—namely, hypertension, age, the triglyceride-glucose (TyG) index, plaque burden, maximum plaque thickness, and intima-media thickness, achieved robust performance (AUC 0.845 in the training cohort and 0.772 in the validation cohort). The model outperformed the traditional FRS (AUC 0.672 in the training cohort and 0.608 in the validation cohort, P < 0.05). SHAP analysis enabled individualized interpretability and clinical insights. A web-based tool was deployed to facilitate clinical application. Conclusions: The predictive model developed in this study by integrating clinical and imaging data, with a focus on the TyG index and ultrasound features, demonstrated enhanced predictive capability for CVD incidence in individuals with new–onset T2D. It also allows easy risk classification and is available as a web tool for real-time use, helping improve early detection and personalized care.


  • Contrast-enhanced ultrasound imaging improves diagnosis of cervical internal carotid artery pseudo occlusion

    by Ying Zhang, Tingting Wang, Xiatian Liu, Lingling Chen, Xiaoming Ding, Jiahui Yu, Dan Ying, Pintong Huang

  • Contrast‐Enhanced Ultrasound Reveals a Rare Pseudo‐Malignant Lesion: Intrahepatic Extramedullary Hematopoiesis

    by Ya‐Lan Zheng, Xia‐Tian Liu, Yuan‐Yuan Zheng, Cai‐Ye Ma, Fang Liu

    Extramedullary hematopoiesis (EMH) is a rare condition where hematopoietic tissue forms outside the bone marrow. We present a case of a patient with long‐standing myelofibrosis and thalassemia, diagnosed with intrahepatic EMH (IEMH) through surgical pathology. This case describes its etiology, pathogenesis, and the causes of misdiagnosis, mainly focusing on the characteristics of contrast‐enhanced ultrasound (CEUS) and magnetic resonance imaging (MRI) of IEMH. The MRI manifestations of IEMH are diverse due to differences in the age and activity of the lesions. Notably, it provides the first description of IEMH's enhancement pattern on CEUS, a potential unique imaging feature of this condition.

  • Feasibility Study of Applying the Modified Hahn Nomenclature for Tricuspid Valve Leaflet Classification in Transthoracic Echocardiography Using the Subxiphoid Short‐Axis View

    by Hua Wang, Xiatian Liu, Zhelan Zheng, Bei Wang

    Objective: This study aims to validate the feasibility of applying an adapted version of the Hahn tricuspid valve nomenclature to classify the leaflets of the tricuspid valve in the subxiphoid short‐axis view (SSAV) using transthoracic echocardiography (TTE).Methods: Referral patients from three medical institutions underwent TTE, with the requirement that the tricuspid valve structure be clearly visible in standard views (AC4 V, PSAV, RVIT, S4CV). The tricuspid valve leaflets were classified retrospectively based on the nomenclature proposed by Hahn et al.Results: Between June 2023 and June 2024, 600 patients' SSAV images were analyzed, with 421 cases (70.2%) successfully classified, while 179 cases (29.8%) failed to be classified. The average age of patients was 58 ± 31 years (range: 27–79 years). There were 334 males (55.7%). The mean weight was 75.7 ± 13.5 kg, and the average BMI was 23.1 ± 3.8 kg/m2. Of the patients, 52.2% had mild or moderate tricuspid regurgitation (TR), 24.3% had severe TR, 22.8% had massive TR, and 2.3% had torrential TR. In the morphological classification of the tricuspid valve, type I was the most common (32.0%), followed by type IIIB (29.8%). Additionally, 179 cases (29.8%) were not successfully classified or determined.Conclusion: SSAV, as an adjunctive imaging view in TTE for assessing the tricuspid valve, shows potential clinical value. Although there are challenges in classifying tricuspid valve leaflets, the method demonstrates certain feasibility.