Lan Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lan Yao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Lishuang Guo
School of Engineering Medicine, Beihang University, Beijing, China
1 shared publication - Rui Ma
Senior Department of Ophthalmology, 3rd Medical Center of Chinese PLA General Hospital, Beijing 100143, China
1 shared publication - Wei Wu
Senior Department of Ophthalmology, 3rd Medical Center of Chinese PLA General Hospital, Beijing, China
1 shared publication - Wenhua Zhang
Research Center for Tissue Repair and Regeneration Affiliated to the Medical Innovation Research Division, 4th Medical Center of Chinese PLA General Hospital, Beijing 100048, China
1 shared publication - Wenlu Liu
Senior Department of Ophthalmology, 3rd Medical Center of Chinese PLA General Hospital, Beijing 100143, China
1 shared publication - Xinji Yang
Senior Department of Ophthalmology, 3rd Medical Center of Chinese PLA General Hospital, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 14 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 922
Orbital Adipose Tissue: The Optimal Control for Back-Table Fluorescence Imaging of Orbital Tumors
Control tissue is essential for ensuring the precision of semiquantitative analysis in back-table fluorescence imaging. However, there remains a lack of agreement on the appropriate selection of control tissues. To evaluate the back-table fluorescence imaging performance of different normal tissues and identify the optimal normal tissue, a cohort of 39 patients with orbital tumors were enrolled in the study. Prior to surgery, these patients received indocyanine green (ICG) and following resection, 43 normal control tissues (34 adipose tissues, 3 skin tissues, 3 periosteal tissues, and 3 muscle tissues) were examined using back-table fluorescence imaging. The skin tissue demonstrated significantly elevated fluorescence intensity in comparison to the diseased tissue, whereas the muscle tissue exhibited a broad range and standard deviation of fluorescence signal intensity. Conversely, the adipose and periosteum displayed weak fluorescence signals with a relatively consistent distribution. Additionally, no significant correlations were found between the signal-to-background ratio (SBR) of adipose tissue and patients’ ages, genders, weights, disease duration, tumor origins, dosing of administration of ICG infusion, and the time interval between ICG infusion and surgery. However, a positive correlation was observed between the SBR of adipose tissue and its size, with larger adipose tissues (>1 cm) showing an average SBR 27% higher than smaller adipose tissues (≤1 cm). In conclusion, the findings of this study demonstrated that adipose tissue consistently exhibited homogeneous hypofluorescence during back-table fluorescence imaging, regardless of patient clinical variables or imaging parameters. The size of the adipose tissue was identified as the primary factor influencing its fluorescence imaging characteristics, supporting its utility as an ideal control tissue for back-table fluorescence imaging.
- 14 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 922
Open AccessOrbital Adipose Tissue: The Optimal Control for Back-Table Fluorescence Imaging of Orbital Tumors
Control tissue is essential for ensuring the precision of semiquantitative analysis in back-table fluorescence imaging. However, there remains a lack of agreement on the appropriate selection of control tissues. To evaluate the back-table fluorescence imaging performance of different normal tissues and identify the optimal normal tissue, a cohort of 39 patients with orbital tumors were enrolled in the study. Prior to surgery, these patients received indocyanine green (ICG) and following resection, 43 normal control tissues (34 adipose tissues, 3 skin tissues, 3 periosteal tissues, and 3 muscle tissues) were examined using back-table fluorescence imaging. The skin tissue demonstrated significantly elevated fluorescence intensity in comparison to the diseased tissue, whereas the muscle tissue exhibited a broad range and standard deviation of fluorescence signal intensity. Conversely, the adipose and periosteum displayed weak fluorescence signals with a relatively consistent distribution. Additionally, no significant correlations were found between the signal-to-background ratio (SBR) of adipose tissue and patients’ ages, genders, weights, disease duration, tumor origins, dosing of administration of ICG infusion, and the time interval between ICG infusion and surgery. However, a positive correlation was observed between the SBR of adipose tissue and its size, with larger adipose tissues (>1 cm) showing an average SBR 27% higher than smaller adipose tissues (≤1 cm). In conclusion, the findings of this study demonstrated that adipose tissue consistently exhibited homogeneous hypofluorescence during back-table fluorescence imaging, regardless of patient clinical variables or imaging parameters. The size of the adipose tissue was identified as the primary factor influencing its fluorescence imaging characteristics, supporting its utility as an ideal control tissue for back-table fluorescence imaging.