    Research on Startup Characteristics of Parallel Axial-Flow Pump Systems

    by Chao Yang, Chao Li, Lingling Deng, You Fu

    This study takes four parallel axial-flow pumps (three in operation + one on standby) as the research object. Using a 1D–3D coupling method, it explores the flow characteristics of axial-flow pumps under different startup strategies during multi-pump parallel operation. Through comparative analysis, the following conclusions are drawn: when all three pumps start simultaneously, the internal pressure exceeds the rated head by 23.43%, and the reverse flow reaches 10.57% of the rated flow. When starting the pumps sequentially with 5 s intervals, the pressure can be reduced to 11.41% above the rated head, but the reverse flow increases to 13.87%. Further extending the startup interval to 15 s results in only minimal improvements compared to 5 s intervals: the maximum internal pressure and maximum reverse flow decrease by just 0.97% and 0.05%, respectively. When valve coordination is added to the 5 s sequential startup strategy (pre-opening the valve to 60% before pump startup), the pressure exceeds the rated head by 10.49%, and the reverse flow exceeds the rated flow by 6.04%. In this scenario, the high-pressure areas and high-turbulence zones on the blade back surfaces are significantly reduced, achieving optimal flow stability. Therefore, the parallel system startup should adopt a coordinated strategy combining moderate time intervals with 60% valve pre-opening. This approach can both avoid excessive pressure impact and effectively control reverse flow phenomena, providing an important basis for optimizing the startup of multi-pump parallel systems.


  • Open Access

    The Influence of Pre-Lift Gate Opening on the Internal and External Flow Characteristics During the Startup Process of an Axial Flow Pump

    by You Fu, Lingling Deng

    This paper focuses on a vertical axial flow pump and employs a 1D-3D coupling method to investigate the effects of different gate pre-opening angles on the internal and external flow characteristics of the axial flow pump during startup. Through comparative analysis, the following conclusions are drawn: In the study, a fully open gate is defined as 1, while a fully closed gate is defined as 0. When starting the axial flow pump with different valve pre-opening degrees, backflow occurs within the first 20 s of startup, and the backflow rate inside the pump gradually increases with the increase in the valve pre-opening degree. At a valve pre-opening degree of 0.6, the maximum backflow rate inside the pump reaches 5.89% of the rated flow rate. When starting the pump with the valve fully open, the maximum backflow rate reaches 10.98% of the rated flow rate, and the efficiency is affected by the backflow rate. The valve pre-opening degree has little impact on the axial force acting on the impeller during startup. When starting with a valve pre-opening degree of 0.6, the internal pressure difference in the pump is minimized. Within the first 20 s of startup, the internal pressure difference in the impeller is 28.96% higher and the flow velocity is 14.62% higher with valve pre-opening degrees of 0.8 and 1.0 compared to a 0.6 degree opening. During the initial stage of pump startup, with valve pre-opening degrees of 0.8 and 1.0, the pressure fluctuation amplitude inside the pump is minimal, with maximum relative amplitudes of only 0.621 and 0.525, which are 41.00% and 28.51% lower than the maximum amplitudes at 0 and 0.2 degrees, respectively. In summary, the peak pressure inside the pump is minimized when the valve pre-opening degree is around 0.8, while the pressure difference and flow velocity are relatively lower at a pre-opening degree of 0.6. It is recommended to start the pump with a valve pre-opening degree of around 0.6 to 0.8.