ATA.D. Taratynova

A.D. Taratynova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


A.D. Taratynova has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative Analysis ofVenous and Paravenous Tissue Damage During Endovascular Laser Ablation with Wavelengths of 1470 and 1940 nm

    by A.N. Belyaev, S.V. Kostin, P.A. Ryabochkina, O.S. Bushukina, S.A. Khrushchalina, V.I. Davydkin, A.D. Taratynova

    The objective of the study was to compare the results of endovenous laser ablation (EVLO) with wavelengths of 1470 and 1940 nm at powers of 5 and 8.5 watts. Materials and methods. In an experiment on sheep, EVLO of the subcutaneous veins of the extremities was performed using a laser with wavelengths of 1470 and 1940 nm and powers of 5 and 8.5 W. Before, during, and 7 days after laser exposure, ultrasound and histological examination of coagulated veins was performed with an assessment of the blood flow rate, the presence of a thrombus in the vein, as well as thermal damage to paravenous tissues. Results. A linear endovenous energy density (LEED) of 25 J/cm at 1470 nm was insufficient for achieving complete vein occlusion while preserving blood flow. Although the LEED value of 42.5 J/cm contributes to the complete vein occlusion, thermal damage to paravenous tissues was observed. The use of a wavelength of 1940 nm and a LEED of 25 J/cm was associated with complete vein occlusion and minor damage to paravenous tissues. Increasing the LEED to 42.5 J/cm causes coagulation necrosis and destruction of the vein wall and paravenous tissues. Conclusion. The optimal mode for EVLO is 1940 nm wavelength with a LEED of 25 J/cm, providing sufficient vein occlusion without significant damage to paravenous tissues.

  • Damage to Vein Wall and Surrounding Tissues During Endovenous Laser Ablation with 1910 nm

    by A.N. Belyaev, P.A. Ryabochkina, S.V. Kostin, O.S. Bushukina, S.A. Khrushchalina, S.A. Artemov, A.D. Taratynova

    Objective. To evaluate vein wall and surrounding tissue damage during endovenous laser ablation (EVLA) with 1910 nm device and different settings. Material and methods. EVLA was performed in 2 sheep under general anesthesia. We used laser fibers with flat and radial tips, wavelength 1910 nm, power 1.5 W, 3 W and 4 W, laser fiber speed extraction 2 mm/sec. Macroscopic and microscopic assessment of damaged veins and surrounding vessels and nerves was carried out considering the distance between the vein wall and damaged structures. Results. Flat fiber at various powers contributed to eccentric vein wall damage up to perforation at a power of 4 W. Damage to perivascular vessels occurred at a distance of 1511±69.3 µm. Ablation with radial laser fiber damaged the vein wall uniformly. Ablation with 4 W damaged all layers of the vein wall. Thermal damage of perivascular vessels was observed at 457.5±30.6 µm from the vein wall. Conclusion. EVLA with 1910 nm laser and radial fibers makes it possible to reduce power to 3—4 W. This prevents vein wall perforation while all layers are damaged. Surrounding structures are damaged at a lesser distance if radial fiber is used.