Yan Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yan Zhao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Alex Mihailidis
KITE Research Institute, Toronto Rehabilitation Institute, University Health Network, Toronto, ON M5G 2A2, Canada
2 shared publications - Bing Ye
Department of Occupational Science and Occupational Therapy, University of Toronto, Toronto, ON M5G 1V7, Canada
2 shared publications - Jessica Babineau
Library and Information Services, University Health Network, Toronto, Canada
2 shared publications - Yan Fu
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications - Yuxin Zhang
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Zhengke Gao
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China, China
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 15, e94022
Effectiveness of Tuina Therapy for Patients With Chronic Fatigue Syndrome: Protocol for a Multicenter, Randomized, Open-Label, Assessor-Blinded, Parallel-Group Clinical Trial
Background: Chronic fatigue syndrome (CFS), also known as myalgic encephalomyelitis (ME), is a debilitating condition characterized by persistent fatigue and a range of complex accompanying symptoms. While curative treatments remain limited, Tuina (a traditional manual therapy in Chinese medicine) has shown potential in alleviating fatigue in pilot studies. However, high-quality evidence from large-scale, multicenter trials regarding its efficacy and long-term sustainability is lacking. Objective: This trial aims to evaluate the efficacy and safety of Tuina combined with usual care (UC) for CFS compared with UC alone. Methods: This prospective, multicenter, randomized, open-label, assessor-blinded, parallel-group clinical trial will be conducted at 6 hospitals in China. The study consists of 3 phases: a 1-week run-in period, an 8-week treatment period, and a 24-week follow-up period. A total of 230 eligible participants diagnosed with CFS (Centers for Disease Control and Prevention 1994 criteria) will be recruited and randomly allocated (1:1) to receive either Tuina therapy plus UC (intervention group) or UC alone (control group). The intervention group will undergo 24 sessions of a standardized Tuina protocol over 8 weeks (3 sessions/week). Follow-up assessments will be conducted at weeks 4, 8, 20, and 32. The primary outcome is the change in fatigue severity measured by the 11-item Chalder Fatigue Questionnaire from baseline to week 8. Secondary outcomes include clinical response rate, sleep quality, anxiety, depression, quality of life, adverse events, and clinical global impression. Efficacy analysis will be performed using a mixed-effects model for repeated measures in the modified intention-to-treat population. Secondary outcomes will be analyzed as exploratory supportive end points using appropriate parametric or nonparametric tests based on data distribution, with week 8 defined as the main secondary time point and later follow-up visits interpreted as durability contrasts. Missing outcome data will be handled primarily through likelihood-based mixed-model estimation under a missing-at-random assumption, with multiple imputation and per-protocol analyses used as sensitivity analyses. Results: Recruitment for this trial will start in March 2026 and is expected to be completed by March 2027. The results of this study are expected to provide reliable evidence regarding the role of Tuina in the management of CFS. Conclusions: This multicenter randomized controlled trial will evaluate the effectiveness, long-term sustainability, and safety of Tuina therapy plus UC for improving fatigue, sleep, mood, and quality of life in CFS or ME. If proven beneficial, Tuina may serve as a scalable nonpharmacological option to support clinical decision-making and standardized implementation.
- 1 September 2026
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 15, e94022
Open AccessEffectiveness of Tuina Therapy for Patients With Chronic Fatigue Syndrome: Protocol for a Multicenter, Randomized, Open-Label, Assessor-Blinded, Parallel-Group Clinical Trial
Background: Chronic fatigue syndrome (CFS), also known as myalgic encephalomyelitis (ME), is a debilitating condition characterized by persistent fatigue and a range of complex accompanying symptoms. While curative treatments remain limited, Tuina (a traditional manual therapy in Chinese medicine) has shown potential in alleviating fatigue in pilot studies. However, high-quality evidence from large-scale, multicenter trials regarding its efficacy and long-term sustainability is lacking. Objective: This trial aims to evaluate the efficacy and safety of Tuina combined with usual care (UC) for CFS compared with UC alone. Methods: This prospective, multicenter, randomized, open-label, assessor-blinded, parallel-group clinical trial will be conducted at 6 hospitals in China. The study consists of 3 phases: a 1-week run-in period, an 8-week treatment period, and a 24-week follow-up period. A total of 230 eligible participants diagnosed with CFS (Centers for Disease Control and Prevention 1994 criteria) will be recruited and randomly allocated (1:1) to receive either Tuina therapy plus UC (intervention group) or UC alone (control group). The intervention group will undergo 24 sessions of a standardized Tuina protocol over 8 weeks (3 sessions/week). Follow-up assessments will be conducted at weeks 4, 8, 20, and 32. The primary outcome is the change in fatigue severity measured by the 11-item Chalder Fatigue Questionnaire from baseline to week 8. Secondary outcomes include clinical response rate, sleep quality, anxiety, depression, quality of life, adverse events, and clinical global impression. Efficacy analysis will be performed using a mixed-effects model for repeated measures in the modified intention-to-treat population. Secondary outcomes will be analyzed as exploratory supportive end points using appropriate parametric or nonparametric tests based on data distribution, with week 8 defined as the main secondary time point and later follow-up visits interpreted as durability contrasts. Missing outcome data will be handled primarily through likelihood-based mixed-model estimation under a missing-at-random assumption, with multiple imputation and per-protocol analyses used as sensitivity analyses. Results: Recruitment for this trial will start in March 2026 and is expected to be completed by March 2027. The results of this study are expected to provide reliable evidence regarding the role of Tuina in the management of CFS. Conclusions: This multicenter randomized controlled trial will evaluate the effectiveness, long-term sustainability, and safety of Tuina therapy plus UC for improving fatigue, sleep, mood, and quality of life in CFS or ME. If proven beneficial, Tuina may serve as a scalable nonpharmacological option to support clinical decision-making and standardized implementation.
- Open Access
- 16 September 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26, e51564
Smartphone-Based Hand Function Assessment: Systematic Review
Background: Hand function assessment heavily relies on specific task scenarios, making it challenging to ensure validity and reliability. In addition, the wide range of assessment tools, limited and expensive data recording, and analysis systems further aggravate the issue. However, smartphones provide a promising opportunity to address these challenges. Thus, the built-in, high-efficiency sensors in smartphones can be used as effective tools for hand function assessment. Objective: This review aims to evaluate existing studies on hand function evaluation using smartphones. Methods: An information specialist searched 8 databases on June 8, 2023. The search criteria included two major concepts: (1) smartphone or mobile phone or mHealth and (2) hand function or function assessment. Searches were limited to human studies in the English language and excluded conference proceedings and trial register records. Two reviewers independently screened all studies, with a third reviewer involved in resolving discrepancies. The included studies were rated according to the Mixed Methods Appraisal Tool. One reviewer extracted data on publication, demographics, hand function types, sensors used for hand function assessment, and statistical or machine learning (ML) methods. Accuracy was checked by another reviewer. The data were synthesized and tabulated based on each of the research questions. Results: In total, 46 studies were included. Overall, 11 types of hand dysfunction–related problems were identified, such as Parkinson disease, wrist injury, stroke, and hand injury, and 6 types of hand dysfunctions were found, namely an abnormal range of motion, tremors, bradykinesia, the decline of fine motor skills, hypokinesia, and nonspecific dysfunction related to hand arthritis. Among all built-in smartphone sensors, the accelerometer was the most used, followed by the smartphone camera. Most studies used statistical methods for data processing, whereas ML algorithms were applied for disease detection, disease severity evaluation, disease prediction, and feature aggregation. Conclusions: This systematic review highlights the potential of smartphone-based hand function assessment. The review suggests that a smartphone is a promising tool for hand function evaluation. ML is a conducive method to classify levels of hand dysfunction. Future research could (1) explore a gold standard for smartphone-based hand function assessment and (2) take advantage of smartphones’ multiple built-in sensors to assess hand function comprehensively, focus on developing ML methods for processing collected smartphone data, and focus on real-time assessment during rehabilitation training. The limitations of the research are 2-fold. First, the nascent nature of smartphone-based hand function assessment led to limited relevant literature, affecting the evidence’s completeness and comprehensiveness. This can hinder supporting viewpoints and drawing conclusions. Second, literature quality varies due to the exploratory nature of the topic, with potential inconsistencies and a lack of high-quality reference studies and meta-analyses.
- 16 September 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26, e51564
Open AccessSmartphone-Based Hand Function Assessment: Systematic Review
Background: Hand function assessment heavily relies on specific task scenarios, making it challenging to ensure validity and reliability. In addition, the wide range of assessment tools, limited and expensive data recording, and analysis systems further aggravate the issue. However, smartphones provide a promising opportunity to address these challenges. Thus, the built-in, high-efficiency sensors in smartphones can be used as effective tools for hand function assessment. Objective: This review aims to evaluate existing studies on hand function evaluation using smartphones. Methods: An information specialist searched 8 databases on June 8, 2023. The search criteria included two major concepts: (1) smartphone or mobile phone or mHealth and (2) hand function or function assessment. Searches were limited to human studies in the English language and excluded conference proceedings and trial register records. Two reviewers independently screened all studies, with a third reviewer involved in resolving discrepancies. The included studies were rated according to the Mixed Methods Appraisal Tool. One reviewer extracted data on publication, demographics, hand function types, sensors used for hand function assessment, and statistical or machine learning (ML) methods. Accuracy was checked by another reviewer. The data were synthesized and tabulated based on each of the research questions. Results: In total, 46 studies were included. Overall, 11 types of hand dysfunction–related problems were identified, such as Parkinson disease, wrist injury, stroke, and hand injury, and 6 types of hand dysfunctions were found, namely an abnormal range of motion, tremors, bradykinesia, the decline of fine motor skills, hypokinesia, and nonspecific dysfunction related to hand arthritis. Among all built-in smartphone sensors, the accelerometer was the most used, followed by the smartphone camera. Most studies used statistical methods for data processing, whereas ML algorithms were applied for disease detection, disease severity evaluation, disease prediction, and feature aggregation. Conclusions: This systematic review highlights the potential of smartphone-based hand function assessment. The review suggests that a smartphone is a promising tool for hand function evaluation. ML is a conducive method to classify levels of hand dysfunction. Future research could (1) explore a gold standard for smartphone-based hand function assessment and (2) take advantage of smartphones’ multiple built-in sensors to assess hand function comprehensively, focus on developing ML methods for processing collected smartphone data, and focus on real-time assessment during rehabilitation training. The limitations of the research are 2-fold. First, the nascent nature of smartphone-based hand function assessment led to limited relevant literature, affecting the evidence’s completeness and comprehensiveness. This can hinder supporting viewpoints and drawing conclusions. Second, literature quality varies due to the exploratory nature of the topic, with potential inconsistencies and a lack of high-quality reference studies and meta-analyses.
- Open Access
- 3 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Smartphone-Based Hand Function Assessment: Systematic Review (Preprint)
BACKGROUND Hand function assessment heavily relies on specific task scenarios, making it challenging to ensure validity and reliability. In addition, the wide range of assessment tools, limited and expensive data recording, and analysis systems further aggravate the issue. However, smartphones provide a promising opportunity to address these challenges. Thus, the built-in, high-efficiency sensors in smartphones can be used as effective tools for hand function assessment. OBJECTIVE This review aims to evaluate existing studies on hand function evaluation using smartphones. METHODS An information specialist searched 8 databases on June 8, 2023. The search criteria included two major concepts: (1) smartphone or mobile phone or mHealth and (2) hand function or function assessment. Searches were limited to human studies in the English language and excluded conference proceedings and trial register records. Two reviewers independently screened all studies, with a third reviewer involved in resolving discrepancies. The included studies were rated according to the Mixed Methods Appraisal Tool. One reviewer extracted data on publication, demographics, hand function types, sensors used for hand function assessment, and statistical or machine learning (ML) methods. Accuracy was checked by another reviewer. The data were synthesized and tabulated based on each of the research questions. RESULTS In total, 46 studies were included. Overall, 11 types of hand dysfunction–related problems were identified, such as Parkinson disease, wrist injury, stroke, and hand injury, and 6 types of hand dysfunctions were found, namely an abnormal range of motion, tremors, bradykinesia, the decline of fine motor skills, hypokinesia, and nonspecific dysfunction related to hand arthritis. Among all built-in smartphone sensors, the accelerometer was the most used, followed by the smartphone camera. Most studies used statistical methods for data processing, whereas ML algorithms were applied for disease detection, disease severity evaluation, disease prediction, and feature aggregation. CONCLUSIONS This systematic review highlights the potential of smartphone-based hand function assessment. The review suggests that a smartphone is a promising tool for hand function evaluation. ML is a conducive method to classify levels of hand dysfunction. Future research could (1) explore a gold standard for smartphone-based hand function assessment and (2) take advantage of smartphones’ multiple built-in sensors to assess hand function comprehensively, focus on developing ML methods for processing collected smartphone data, and focus on real-time assessment during rehabilitation training. The limitations of the research are 2-fold. First, the nascent nature of smartphone-based hand function assessment led to limited relevant literature, affecting the evidence’s completeness and comprehensiveness. This can hinder supporting viewpoints and drawing conclusions. Second, literature quality varies due to the exploratory nature of the topic, with potential inconsistencies and a lack of high-quality reference studies and meta-analyses.
- 3 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessSmartphone-Based Hand Function Assessment: Systematic Review (Preprint)
BACKGROUND Hand function assessment heavily relies on specific task scenarios, making it challenging to ensure validity and reliability. In addition, the wide range of assessment tools, limited and expensive data recording, and analysis systems further aggravate the issue. However, smartphones provide a promising opportunity to address these challenges. Thus, the built-in, high-efficiency sensors in smartphones can be used as effective tools for hand function assessment. OBJECTIVE This review aims to evaluate existing studies on hand function evaluation using smartphones. METHODS An information specialist searched 8 databases on June 8, 2023. The search criteria included two major concepts: (1) smartphone or mobile phone or mHealth and (2) hand function or function assessment. Searches were limited to human studies in the English language and excluded conference proceedings and trial register records. Two reviewers independently screened all studies, with a third reviewer involved in resolving discrepancies. The included studies were rated according to the Mixed Methods Appraisal Tool. One reviewer extracted data on publication, demographics, hand function types, sensors used for hand function assessment, and statistical or machine learning (ML) methods. Accuracy was checked by another reviewer. The data were synthesized and tabulated based on each of the research questions. RESULTS In total, 46 studies were included. Overall, 11 types of hand dysfunction–related problems were identified, such as Parkinson disease, wrist injury, stroke, and hand injury, and 6 types of hand dysfunctions were found, namely an abnormal range of motion, tremors, bradykinesia, the decline of fine motor skills, hypokinesia, and nonspecific dysfunction related to hand arthritis. Among all built-in smartphone sensors, the accelerometer was the most used, followed by the smartphone camera. Most studies used statistical methods for data processing, whereas ML algorithms were applied for disease detection, disease severity evaluation, disease prediction, and feature aggregation. CONCLUSIONS This systematic review highlights the potential of smartphone-based hand function assessment. The review suggests that a smartphone is a promising tool for hand function evaluation. ML is a conducive method to classify levels of hand dysfunction. Future research could (1) explore a gold standard for smartphone-based hand function assessment and (2) take advantage of smartphones’ multiple built-in sensors to assess hand function comprehensively, focus on developing ML methods for processing collected smartphone data, and focus on real-time assessment during rehabilitation training. The limitations of the research are 2-fold. First, the nascent nature of smartphone-based hand function assessment led to limited relevant literature, affecting the evidence’s completeness and comprehensiveness. This can hinder supporting viewpoints and drawing conclusions. Second, literature quality varies due to the exploratory nature of the topic, with potential inconsistencies and a lack of high-quality reference studies and meta-analyses.