Wilhem Rogger Limachi Viamonte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wilhem Rogger Limachi Viamonte has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Julio Fredy Chura Acero
Affiliation Faculty of FIMEES, Universidad Nacional del Altiplano, Puno, Perú
1 shared publication Norman Jesus Beltran Castanon Wilhem
Mechanical Electrical Engineering, National University of the Altiplano,Puno,Peru
1 shared publication- Omar Chayña Velasquez
Department of Mechanical Electrical Engineering, Universidad Nacional del Altiplano, Puno 21000, Peru
1 shared publication
Latest Publications
- Open Access
- 31 March 2024
- Published by Escuela de Posgrado de la Universidad Nacional del Altiplano in Revista de Investigaciones
- Vol. 13 (1) , 38-47
Análisis del efecto de cavitación en una turbina hidráulica de tipo francis en condiciones de operación de la C.H. Chaglla
The performance of a hydropower plant depends on several parameters, i.e., the turbine type used, plant design, turbine classification, plant head, flow rate. All turbines are used for their best operation under the best level of efficiency with optimal values for their nominal head, water flow and turbine speed. However, under these conditions, the cavitation phenomenon occurs in the hydraulic turbine. It is only for the reason that the dynamic attribute of liquid flow becomes unstable with high pressure fluctuations. Cavitation is an unavoidable and unavoidable problem in hydraulic turbines. Cavitation destroys the performance of the turbines. When turbines operate at partial loads rather than their highest efficiency point, they experience cavitation to a greater extent. Francis turbines are designed to be operated in various conditions. The research objective was to analyze the cavitation occurrence in a Francis type turbine and how to minimize it, as a result a report was obtained on damages caused by the bubbles implosion on the surfaces of the turbine, especially in the impeller, at the exit waist edge of the intermediate zone in UG-1, present areas with cavitation wear between blade and blade 1-2. 3-4. 8-9. 11-12. 13-1. According to the inspection, the evolution of the cavitated areas is controlled and a slight detachment of material is observed, which does not compromise the useful life of the impeller. Likewise, for the impeller blades in the UG-2, cavitation wear areas occur between blade and blade 3-4. 9-10. 11-12; It is also controlled and slight material release is observed which does not compromise the useful life of the impeller. Regarding the wear of the blades in the impeller, we can indicate that in the UG2 there is 6.47 % accumulated wear, while in the UG1 there is 5.47 %. In the case of the guide vanes, the wear clearance with the highest incidence is in the UG2 with 0.692 mm of accumulated wear, while in the UG1 with 0.2595 mm.
- 31 March 2024
- Published by Escuela de Posgrado de la Universidad Nacional del Altiplano in Revista de Investigaciones
- Vol. 13 (1) , 38-47
Open AccessAnálisis del efecto de cavitación en una turbina hidráulica de tipo francis en condiciones de operación de la C.H. Chaglla
The performance of a hydropower plant depends on several parameters, i.e., the turbine type used, plant design, turbine classification, plant head, flow rate. All turbines are used for their best operation under the best level of efficiency with optimal values for their nominal head, water flow and turbine speed. However, under these conditions, the cavitation phenomenon occurs in the hydraulic turbine. It is only for the reason that the dynamic attribute of liquid flow becomes unstable with high pressure fluctuations. Cavitation is an unavoidable and unavoidable problem in hydraulic turbines. Cavitation destroys the performance of the turbines. When turbines operate at partial loads rather than their highest efficiency point, they experience cavitation to a greater extent. Francis turbines are designed to be operated in various conditions. The research objective was to analyze the cavitation occurrence in a Francis type turbine and how to minimize it, as a result a report was obtained on damages caused by the bubbles implosion on the surfaces of the turbine, especially in the impeller, at the exit waist edge of the intermediate zone in UG-1, present areas with cavitation wear between blade and blade 1-2. 3-4. 8-9. 11-12. 13-1. According to the inspection, the evolution of the cavitated areas is controlled and a slight detachment of material is observed, which does not compromise the useful life of the impeller. Likewise, for the impeller blades in the UG-2, cavitation wear areas occur between blade and blade 3-4. 9-10. 11-12; It is also controlled and slight material release is observed which does not compromise the useful life of the impeller. Regarding the wear of the blades in the impeller, we can indicate that in the UG2 there is 6.47 % accumulated wear, while in the UG1 there is 5.47 %. In the case of the guide vanes, the wear clearance with the highest incidence is in the UG2 with 0.692 mm of accumulated wear, while in the UG1 with 0.2595 mm.
- 23 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Harmonic Distortion Effects of the Wind Farm Connected to the Grid. Case Study for Marcona at 32 MW
This article analyzes the impact of the integration of large-scale wind generation in an Electric Power System, due to the fact that its intermittent nature and the type of wind turbine it uses, inject harmonic currents that cause harmonic distortions in the electrical network to which they connect. The objective is to determine the effects of the harmonic distortion of the Marcona wind farm connected to the grid with an installed power of 32 MW; produced after commissioning, analyzed in the 220 kV bus of the Tres Hermanas SE. Harmonic resonance points produced in the system were identified through frequency sweep analysis. So that later, through the analysis of the Harmonic Flow of Power, the total harmonic distortion (THD) in the 220 kV bus of the Tres Hermanas SE is known and it can be compared with the limits required by the power quality regulations.
- 23 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Harmonic Distortion Effects of the Wind Farm Connected to the Grid. Case Study for Marcona at 32 MW
This article analyzes the impact of the integration of large-scale wind generation in an Electric Power System, due to the fact that its intermittent nature and the type of wind turbine it uses, inject harmonic currents that cause harmonic distortions in the electrical network to which they connect. The objective is to determine the effects of the harmonic distortion of the Marcona wind farm connected to the grid with an installed power of 32 MW; produced after commissioning, analyzed in the 220 kV bus of the Tres Hermanas SE. Harmonic resonance points produced in the system were identified through frequency sweep analysis. So that later, through the analysis of the Harmonic Flow of Power, the total harmonic distortion (THD) in the 220 kV bus of the Tres Hermanas SE is known and it can be compared with the limits required by the power quality regulations.