Rawan Mufeed Jameel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rawan Mufeed Jameel has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Aseel Mohammed Al-Khafaji
Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
2 shared publications Lesovik V Stanislavovich
Department of Materials Science, Products and Structures, Belgorod State Technological University named after V.G. Shoukhov, Belgorod, Russian Federation
1 shared publication
Latest Publications
- Open Access
- 15 September 2025
- Published by Journal of Baghdad College of Dentistry in Journal of Baghdad College of Dentistry
- Vol. 37 (3) , 90-99
The clinical effectiveness assessment of proposed digital dental planning and digital smile prototypes design
Background: Modern technologies in dentistry are one of the effective methods to obtain results that are acceptable to the patient, as well as reducing time, effort, and cost. Materials and Methods: The effectiveness of the developed digital dental treatment planning was evaluated by assessing the results of a survey of 50 patients in need of dental implant prosthesis for aesthetic faults of the anterior tееth at the prototype stage. The Oral Health Impact Profile-14 (OHIP-14) was created to measure the impact that oral health issues can have on a person's life. Results: after the mockup the relative occlusal load distribution between the right and left sides was 50.40 ± 0.90% with balanced occlusion.The dental closing time was 0.17± 0.07 s; and the dental opening time was 0.19 ±0.04 s. The difference in timing between the left and right latеrntrusions is -0.030 ± 0.03. During protrusion, the opening time was less than 0.6 s. (0.170 ± 0.07). The time required to close the teeth to reach the maximum intercuspation was 0.20 ± 0.02 s, where the time required to open them was 0.170 ± 0.02 s. Conclusion: Prior to the mock-up, the patients' average relative occlusal load distribution was 51.5±1.20% on the left and right sides. After the mock-up, it was found that the relative occlusal load distribution between the left and right sides was 50.40±0.90%. These results point to stable and successful occlusal balance restoration following mock-up. After using the OHIP-14 questionnaire to summarize the survey results, we can say that patients' quality of life has enhanced by a factor of two.
- 15 September 2025
- Published by Journal of Baghdad College of Dentistry in Journal of Baghdad College of Dentistry
- Vol. 37 (3) , 90-99
Open AccessThe clinical effectiveness assessment of proposed digital dental planning and digital smile prototypes design
Background: Modern technologies in dentistry are one of the effective methods to obtain results that are acceptable to the patient, as well as reducing time, effort, and cost. Materials and Methods: The effectiveness of the developed digital dental treatment planning was evaluated by assessing the results of a survey of 50 patients in need of dental implant prosthesis for aesthetic faults of the anterior tееth at the prototype stage. The Oral Health Impact Profile-14 (OHIP-14) was created to measure the impact that oral health issues can have on a person's life. Results: after the mockup the relative occlusal load distribution between the right and left sides was 50.40 ± 0.90% with balanced occlusion.The dental closing time was 0.17± 0.07 s; and the dental opening time was 0.19 ±0.04 s. The difference in timing between the left and right latеrntrusions is -0.030 ± 0.03. During protrusion, the opening time was less than 0.6 s. (0.170 ± 0.07). The time required to close the teeth to reach the maximum intercuspation was 0.20 ± 0.02 s, where the time required to open them was 0.170 ± 0.02 s. Conclusion: Prior to the mock-up, the patients' average relative occlusal load distribution was 51.5±1.20% on the left and right sides. After the mock-up, it was found that the relative occlusal load distribution between the left and right sides was 50.40±0.90%. These results point to stable and successful occlusal balance restoration following mock-up. After using the OHIP-14 questionnaire to summarize the survey results, we can say that patients' quality of life has enhanced by a factor of two.
- Open Access
- 19 September 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (5) , 1133-1148
The Influence of Various Superstructure Materials on Stress Distribution for Implant-Supported Prosthesis: Three-Dimensional Finite Element Analysis
In different applied load scenarios, this study evaluates the distribution of stress in the implant and bone exerted by zirconia, lithium disilicate, and cobalt chromium alloy. A 3D virtual model of a mandibular three-unit implant-supported prosthesis was created using SolidWorks 2022. The model featured two 12-mm Straumann Ti-Zr (Roxolid) implants with diameters of 4.5 mm and 4 mm. Zirconia, lithium disilicate, and cobalt chromium alloy were used as superstructure materials. Vertical loads of 100 N and 200 N were applied to the central fossa of the implant-supported prosthesis. The finite element analysis demonstrated that doubling the applied load leads to a proportional increase in von Mises stress on both the implant and bone in a mandibular posterior three-unit implant-supported prosthesis model. Zirconia and chromium cobalt as superstructure materials result in similar stress levels due to their closely matched elastic moduli of 200 GPa and 218 GPa, respectively. In contrast, lithium disilicate leads to the highest stress levels, which is attributed to its lower elastic modulus of 95 GPa. These findings highlight the critical role of superstructure material properties in stress distribution. Zirconia emerges as the preferred material for implant-supported prosthetics due to its favorable stress distribution.
- 19 September 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (5) , 1133-1148
Open AccessThe Influence of Various Superstructure Materials on Stress Distribution for Implant-Supported Prosthesis: Three-Dimensional Finite Element Analysis
In different applied load scenarios, this study evaluates the distribution of stress in the implant and bone exerted by zirconia, lithium disilicate, and cobalt chromium alloy. A 3D virtual model of a mandibular three-unit implant-supported prosthesis was created using SolidWorks 2022. The model featured two 12-mm Straumann Ti-Zr (Roxolid) implants with diameters of 4.5 mm and 4 mm. Zirconia, lithium disilicate, and cobalt chromium alloy were used as superstructure materials. Vertical loads of 100 N and 200 N were applied to the central fossa of the implant-supported prosthesis. The finite element analysis demonstrated that doubling the applied load leads to a proportional increase in von Mises stress on both the implant and bone in a mandibular posterior three-unit implant-supported prosthesis model. Zirconia and chromium cobalt as superstructure materials result in similar stress levels due to their closely matched elastic moduli of 200 GPa and 218 GPa, respectively. In contrast, lithium disilicate leads to the highest stress levels, which is attributed to its lower elastic modulus of 95 GPa. These findings highlight the critical role of superstructure material properties in stress distribution. Zirconia emerges as the preferred material for implant-supported prosthetics due to its favorable stress distribution.
- Open Access
- 1 January 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 11649-11659
The influence of different occlusal design of 3-unit lithium disilicate implant supported prosthesis: Three-dimensional finite element analysis
This study was undertaken to assess the influence of different buccolingual offset of occlusal table on the stress distribution in bone, implant and prosthesis in four virtual models of 3_unit mandibular implant supported prosthesis. Materials and methods: Geometric models of prosthesis, implant, and mandibular bone were created using SolidWorks and Ansys. Four three-dimensional models of the mandibular posterior segment with a 3-unit implant-supported prosthesis were reconstructed. The models had buccolingual offsets of 70%, 80%, and 90%, and one model without an offset. Vertical forces of 100 N and 200 N were applied to analyze stress distribution. Results: At 100 N, optimal stress distribution is found in the 80% buccolingual offset model. At 200 N, the best stress distribution occurs in the 90% and 100% models. Stress behavior changes significantly with increased force. At 100 N, the second implant-supported molar in the 100% model experiences the least stress, while at 200 N, it experiences the most stress in the 70% model. Thus, the ideal stress distribution varies with load and buccolingual offset, with 80% being optimal at 100 N and higher offsets preferred at 200 N. Conclusion: The present research demonstrates that stress distribution in implant-supported prostheses varies with changes in the buccolingual width of the occlusal table. ANSYS calculations revealed that stress levels decrease as buccolingual width increases, with 80% buccolingual offset for appropriate stress distribution. Under a 100 N load, the ideal stress distribution is at 80% buccolingual offset. At a 200 N load, stress distribution varies significantly, with the lowest stress at 100% buccolingual width in the second implant-supported molar and the highest at 70% buccolingual width in the same area. Thus, stress transfer to the peri-implant bone varies with buccolingual offset, with 80% width being optimal under 100 N load.
- 1 January 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 11649-11659
Open AccessThe influence of different occlusal design of 3-unit lithium disilicate implant supported prosthesis: Three-dimensional finite element analysis
This study was undertaken to assess the influence of different buccolingual offset of occlusal table on the stress distribution in bone, implant and prosthesis in four virtual models of 3_unit mandibular implant supported prosthesis. Materials and methods: Geometric models of prosthesis, implant, and mandibular bone were created using SolidWorks and Ansys. Four three-dimensional models of the mandibular posterior segment with a 3-unit implant-supported prosthesis were reconstructed. The models had buccolingual offsets of 70%, 80%, and 90%, and one model without an offset. Vertical forces of 100 N and 200 N were applied to analyze stress distribution. Results: At 100 N, optimal stress distribution is found in the 80% buccolingual offset model. At 200 N, the best stress distribution occurs in the 90% and 100% models. Stress behavior changes significantly with increased force. At 100 N, the second implant-supported molar in the 100% model experiences the least stress, while at 200 N, it experiences the most stress in the 70% model. Thus, the ideal stress distribution varies with load and buccolingual offset, with 80% being optimal at 100 N and higher offsets preferred at 200 N. Conclusion: The present research demonstrates that stress distribution in implant-supported prostheses varies with changes in the buccolingual width of the occlusal table. ANSYS calculations revealed that stress levels decrease as buccolingual width increases, with 80% buccolingual offset for appropriate stress distribution. Under a 100 N load, the ideal stress distribution is at 80% buccolingual offset. At a 200 N load, stress distribution varies significantly, with the lowest stress at 100% buccolingual width in the second implant-supported molar and the highest at 70% buccolingual width in the same area. Thus, stress transfer to the peri-implant bone varies with buccolingual offset, with 80% width being optimal under 100 N load.