Axl F. Rogers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Axl F. Rogers has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Willem van Straten
Institute for Radio Astronomy & Space Research Auckland University of Technology Private Bag 92006 1142 Auckland New Zealand
3 shared publications - Aditya Parthasarathy
Max-Planck-Institut für Radioastronomie , Auf dem Hügel 69, D-53121 Bonn
2 shared publications - Agastya Kapur
Australia Telescope National Facility, CSIRO, Space and Astronomy, PO Box 76, Epping, NSW 1710, Australia
2 shared publications - Boris Goncharov
Gran Sasso Science Institute (GSSI)
2 shared publications - Christopher J. Russell
CSIRO Scientific Computing
2 shared publications - Daniel J. Reardon
Centre for Astrophysics and Supercomputing, Swinburne University of Technology , PO Box 218, Hawthorn, VIC 3122
2 shared publications
Latest Publications
- Open Access
- 23 September 2024
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 973 (2) , 94
Reducing Instrumental Errors in Parkes Pulsar Timing Array Data
This paper demonstrates the impact of state-of-the-art instrumental calibration techniques on the precision of arrival times obtained from 9.6 yr of observations of millisecond pulsars using the Murriyang 64 m CSIRO Parkes Radio Telescope. Our study focuses on 21 cm observations of 25 high-priority pulsars that are regularly observed as part of the Parkes Pulsar Timing Array project, including those predicted to be the most susceptible to calibration errors. We employ measurement equation template matching (METM) for instrumental calibration and matrix template matching (MTM) for arrival time estimation, resulting in significantly improved timing residuals with up to a sixfold reduction in white noise compared to arrival times estimated using scalar template matching and conventional calibration based on the ideal feed assumption. The median relative reduction in white noise is 33%, and the maximum absolute reduction is 4.5 μs. For PSR J0437−4715, METM and MTM reduce the best-fit power-law amplitude (2.7σ) and spectral index (1.7σ) of the red noise in the arrival time residuals, which can be tentatively interpreted as mitigation of 1/f noise due to otherwise unmodeled steps in polarimetric response. These findings demonstrate the potential to directly enhance the sensitivity of pulsar timing array experiments through more accurate methods of instrumental calibration and arrival time estimation.
- 23 September 2024
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 973 (2) , 94
Open AccessReducing Instrumental Errors in Parkes Pulsar Timing Array Data
This paper demonstrates the impact of state-of-the-art instrumental calibration techniques on the precision of arrival times obtained from 9.6 yr of observations of millisecond pulsars using the Murriyang 64 m CSIRO Parkes Radio Telescope. Our study focuses on 21 cm observations of 25 high-priority pulsars that are regularly observed as part of the Parkes Pulsar Timing Array project, including those predicted to be the most susceptible to calibration errors. We employ measurement equation template matching (METM) for instrumental calibration and matrix template matching (MTM) for arrival time estimation, resulting in significantly improved timing residuals with up to a sixfold reduction in white noise compared to arrival times estimated using scalar template matching and conventional calibration based on the ideal feed assumption. The median relative reduction in white noise is 33%, and the maximum absolute reduction is 4.5 μs. For PSR J0437−4715, METM and MTM reduce the best-fit power-law amplitude (2.7σ) and spectral index (1.7σ) of the red noise in the arrival time residuals, which can be tentatively interpreted as mitigation of 1/f noise due to otherwise unmodeled steps in polarimetric response. These findings demonstrate the potential to directly enhance the sensitivity of pulsar timing array experiments through more accurate methods of instrumental calibration and arrival time estimation.
- Open Access
Reducing instrumental errors in Parkes Pulsar Timing Array data
This paper demonstrates the impact of state-of-the-art instrumental calibration techniques on the precision of arrival times obtained from 9.6 years of observations of millisecond pulsars using the Murriyang 64-m CSIRO Parkes Radio Telescope. Our study focuses on 21-cm observations of 25 high-priority pulsars that are regularly observed as part of the Parkes Pulsar Timing Array (PPTA) project, including those predicted to be the most susceptible to calibration errors. We employ Measurement Equation Template Matching (METM) for instrumental calibration and Matrix Template Matching (MTM) for arrival time estimation, resulting in significantly improved timing residuals with up to a sixfold reduction in white noise compared to arrival times estimated using Scalar Template Matching and conventional calibration based on the Ideal Feed Assumption. The median relative reduction in white noise is 33 percent, and the maximum absolute reduction is 4.5 microseconds. For PSR J0437-4715, METM and MTM reduce the best-fit power-law amplitude (2.7 sigma) and spectral index (1.7 sigma) of the red noise in the arrival time residuals, which can can be tentatively interpreted as mitigation of 1/f noise due to otherwise unmodeled steps in polarimetric response. These findings demonstrate the potential to directly enhance the sensitivity of pulsar timing array experiments through more accurate methods of instrumental calibration and arrival time estimation.
Open AccessReducing instrumental errors in Parkes Pulsar Timing Array data
This paper demonstrates the impact of state-of-the-art instrumental calibration techniques on the precision of arrival times obtained from 9.6 years of observations of millisecond pulsars using the Murriyang 64-m CSIRO Parkes Radio Telescope. Our study focuses on 21-cm observations of 25 high-priority pulsars that are regularly observed as part of the Parkes Pulsar Timing Array (PPTA) project, including those predicted to be the most susceptible to calibration errors. We employ Measurement Equation Template Matching (METM) for instrumental calibration and Matrix Template Matching (MTM) for arrival time estimation, resulting in significantly improved timing residuals with up to a sixfold reduction in white noise compared to arrival times estimated using Scalar Template Matching and conventional calibration based on the Ideal Feed Assumption. The median relative reduction in white noise is 33 percent, and the maximum absolute reduction is 4.5 microseconds. For PSR J0437-4715, METM and MTM reduce the best-fit power-law amplitude (2.7 sigma) and spectral index (1.7 sigma) of the red noise in the arrival time residuals, which can can be tentatively interpreted as mitigation of 1/f noise due to otherwise unmodeled steps in polarimetric response. These findings demonstrate the potential to directly enhance the sensitivity of pulsar timing array experiments through more accurate methods of instrumental calibration and arrival time estimation.
- Open Access
- 16 May 2019
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 487 (1) , 1191-1199
Polarization studies of rotating radio transients
We study the polarization properties of 22 known rotating radio transients (RRATs) with the 64-m Parkes radio telescope and present the Faraday rotation measures (RMs) for the 17 with linearly polarized flux exceeding the off-pulse noise by 3σ. Each RM was estimated using a brute-force search over trial RMs that spanned the maximum measurable range |$\pm 1.18 \times 10^5 \, \mathrm{rad \, m^2}$| (in steps of 1 |$\mathrm{rad \, m^2}$|), followed by an iterative refinement algorithm. The measured RRAT RMs are in the range |RM| 1–950 rad m−2 with an average linear polarization fraction of 40 per cent. Individual single pulses are observed to be up to 100 per cent linearly polarized. The RMs of the RRATs and the corresponding inferred average magnetic fields (parallel to the line of sight and weighted by the free electron density) are observed to be consistent with the Galactic plane pulsar population. Faraday rotation analyses are typically performed on accumulated pulsar data, for which hundreds to thousands of pulses have been integrated, rather than on individual pulses. Therefore, we verified the iterative refinement algorithm by performing Monte Carlo simulations of artificial single pulses over a wide range of S/N and RM. At and above an S/N of 17 in linearly polarized flux, the iterative refinement recovers the simulated RM value 100 per cent of the time with a typical mean uncertainty of 5 rad m−2. The method described and validated here has also been successfully used to determine reliable RMs of several fast radio bursts (FRBs) discovered at Parkes.
- 16 May 2019
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 487 (1) , 1191-1199
Open AccessPolarization studies of rotating radio transients
We study the polarization properties of 22 known rotating radio transients (RRATs) with the 64-m Parkes radio telescope and present the Faraday rotation measures (RMs) for the 17 with linearly polarized flux exceeding the off-pulse noise by 3σ. Each RM was estimated using a brute-force search over trial RMs that spanned the maximum measurable range |$\pm 1.18 \times 10^5 \, \mathrm{rad \, m^2}$| (in steps of 1 |$\mathrm{rad \, m^2}$|), followed by an iterative refinement algorithm. The measured RRAT RMs are in the range |RM| 1–950 rad m−2 with an average linear polarization fraction of 40 per cent. Individual single pulses are observed to be up to 100 per cent linearly polarized. The RMs of the RRATs and the corresponding inferred average magnetic fields (parallel to the line of sight and weighted by the free electron density) are observed to be consistent with the Galactic plane pulsar population. Faraday rotation analyses are typically performed on accumulated pulsar data, for which hundreds to thousands of pulses have been integrated, rather than on individual pulses. Therefore, we verified the iterative refinement algorithm by performing Monte Carlo simulations of artificial single pulses over a wide range of S/N and RM. At and above an S/N of 17 in linearly polarized flux, the iterative refinement recovers the simulated RM value 100 per cent of the time with a typical mean uncertainty of 5 rad m−2. The method described and validated here has also been successfully used to determine reliable RMs of several fast radio bursts (FRBs) discovered at Parkes.